Laserfiche WebLink
LEGEND <br />SW 1/4, SEC. 07, TWP. 28N., R05E, W.M. <br />ABBREVIATIONS <br />CITY OF EVERETT STANDARD PLAN NOTES <br />ROADWAY CENTERLINE <br />PROJECT BOUNDARY LINE <br />PROPERTY BOUNDARY LINE <br />RIGHT-OF-WAY LINE <br />EASEMENT LINE <br />EDGE OF PAVEMENT LINE <br />10' CONTOUR LINE <br />2' CONTOUR LINE <br />SANITARY SEWER MAIN <br />WATER LINE <br />FIRE SUPPLY <br />STORM PIPE <br />GAS LINE <br />FENCE LINE <br />POWER LINE <br />BURIED POWER LINE <br />UTILITY EASEMENT <br />TELEPHONE LINE <br />BURIED TELEPHONE LINE <br />SWALE <br />SILT FENCE <br />TEMP. CONSTRUCTION FENCING <br />CLEARING LIMIT <br />SANITARY SEWER CLEAN OUT <br />SANITARY SEWER MANHOLE <br />STORM DRAIN CATCH BASIN - TYPE I <br />STORM DRAIN CATCH BASIN - TYPE I <br />STORM DRAIN INLET (NO CATCH) <br />STORM DRAIN CULVERT <br />WATER CAP/PLUG <br />WATER COUPLING <br />GUARD POST <br />REDUCER <br />THRUST BLOCK <br />WATER METER <br />2 NOZZLE FIRE HYDRANT <br />3 NOZZLE FIRE HYDRANT <br />FLANGE/BUND FL JOINT <br />MECHANICAL JOINT <br />PUSH-ON/HUB JOINT <br />THREAD JOINT <br />AIR RELIEF VALVE <br />BLOW -OFF VALVE <br />BUTTERFLY VALVE <br />CHECK VALVE <br />GATE/GENERAL VALVE <br />PLUG VALVE <br />GAS METER <br />GAS VALVE <br />PAD MOUNTED TRANSFORMER <br />POWER VAULT <br />TRANSMISSION TOWER (SCALEABLE) <br />UTILITY POLE <br />POWER POLE <br />UTILITY POLE ANCHOR <br />TELEPHONE RISER <br />TELEPHONE VAULT <br />BUS STOP <br />MAIL BOX <br />RIP RAP <br />ROCKERY <br />SHRUB <br />GENERAL SIGN <br />REGULATORY SIGN <br />TREE (CONIFER) <br />TREE (DECIDUOUS) <br />YARD LIGHT <br />BRIDGE/TUNNEL <br />ASPHALT PAVEMENT <br />CONCRETE <br />15 V <br />r whaPa below. <br />:allh.r,.,.. ii <br />EXISTING <br />PROPOSED <br />SS SS SS <br />W <br />F -F -F -F -F -F -F -F - <br />SD <br />GAS GAS <br />X <br />OP <br />BP <br />T <br />BT <br />-X-X-X-X-X- <br />0 0 0 <br />0 <br />O • <br />El <br />o � <br />A <br />0 • <br />D ► <br />a <br />A 1R <br />C C <br />C C <br />i' <br />P T <br />� W <br />N N <br />� N <br />0 0 <br />� ql <br />0 ❑� <br />o ■ <br />0 0 <br />eus eus <br />o � <br />01 <br />i <br />� 1 <br />0 0 <br />0 <br />AC <br />ASPHALT CONCRETE PAVEMENT <br />LCPE <br />LINED CORRUGATED POLYETHYLENE PIPE <br />AP <br />ANGLE POINT <br />LF <br />LINEAL FEET <br />ATB <br />ASPHALT TREATED BASE <br />LT <br />LEFT <br />AVE <br />AVENUE <br />LUI <br />LAND USE INSPECTOR <br />BCR <br />BEGIN CURB RETURN <br />MAX. <br />MAXIMUM <br />BOC <br />BACK OF CURB <br />MSE <br />MECHANICALLY STABILIZED EARTH <br />BOW <br />BOTTOM OF WALL <br />MH <br />MANHOLE <br />CASP <br />CRITICAL AREA SITE PLAN <br />MIN. <br />MINIMUM <br />q <br />CENTERLINE <br />MJ <br />MECHANICAL JOINT <br />CB <br />CATCH BASIN <br />N <br />NORTH <br />CDF <br />CONTROLLED DENSITY FILL <br />NIC <br />NOT IN CONTRACT <br />CMP <br />CORRUGATED METAL PIPE <br />0. C. <br />ON CENTER <br />COE <br />CITY OF EVERETT <br />PC <br />POINT OF CURVATURE <br />CONC. <br />CONCRETE <br />PE <br />PLAIN END <br />CONN. <br />CONNECTION <br />PI <br />POINT OF INTERSECTION <br />CONT, <br />CONTINUOUS <br />PL <br />PLACE <br />CPP <br />CORRUGATED POLYETHYLENE PIPE <br />PT <br />POINT OF TANGENCY <br />(W/SMOOTH INTERIOR WALLS) <br />Pw <br />POINT OF VERTICAL INTERSECTION <br />CSBC <br />CCRRUSHED SURFACING BASE COURSE <br />PUE <br />PUBLIC UTILITY EASEMENT <br />CSTC <br />CRUSHED SURFACING TOP COURSE <br />PWS <br />PUBLIC WORKS STANDARDS <br />DIA. <br />DIAMETER <br />REQb. <br />REQUIRED <br />DI <br />DUCTILE IRON <br />ROW <br />RIGHT-OF-WAY <br />DW <br />DRIVEWAY <br />RT <br />RIGHT <br />E <br />EAST <br />S <br />SOUTH <br />ECR <br />END CURB RETURN <br />SD <br />STORM DRAIN <br />EDDS <br />ENGINEERING DESIGN AND <br />SP <br />SPACE <br />DEVELOPMENT STANDARDS <br />SS <br />SANITARY SEWER <br />EL. <br />ELEVATION <br />SSD <br />STOPPING SIGHT DISTANCE <br />EDP <br />EDGE OF PAVEMENT <br />STA <br />STATION <br />ESC <br />EROSION AND SEDIMENT CONTROL <br />TESC <br />TEMPORARY EROSION AND SEDIMENT CONTROL <br />ESD <br />ENTERING SIGHT DISTANCE <br />TOC <br />TOP OF CURB <br />ESMT. <br />EASEMENT <br />TYR <br />TYPICAL <br />EVA <br />EMERGENCY VEHICLE ACCESS <br />TBW <br />TOP BACK OF WALK <br />EXIST. <br />EXISTING <br />TOW <br />TOP OF WALL <br />FL <br />FLOW LINE <br />UNO <br />UNLESS NOTED OTHERWISE <br />FL. <br />FLANGE <br />VERT. <br />VERTICAL <br />FOC <br />FACE OF CURB <br />WSDOT <br />WASHINGTON DEPT. OF TRANSPORTATION <br />HORIZ <br />HORIZONTAL <br />W <br />WITH <br />IE <br />INVERT ELEVATION <br />w <br />WEST <br />INT <br />INTERSECTION <br />WS <br />WATER SERVICE <br />GENERAL PROJECT NOTES <br />1. ALL WORKMANSHIP, METHODS AND MATERIALS FOR THIS PROJECT SHALL CONFORM TO THE LATEST EDITION <br />OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION AS PRODUCED BY <br />WSDOT AND THE WASHINGTON STATE CHAPTER OF THE APWA; CITY OF EVERETT DESIGN AND CONSTRUCTION <br />STANDARDS AND SPECIFICATIONS FOR DEVELOPMENT AND ANY SPECIAL PROVISIONS PROVIDED BY THESE <br />PLANS OR OTHER CONTRACT DOCUMENTS FOR THE PROJECT. <br />2. EXISTING UTILITIES ARE SHOWN IN THESE PLANS PER THE LATEST AVAILABLE INFORMATION. THE <br />CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND RELATED SURFACE FEATURES WITHIN THE <br />PROJECT AREA AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PLAN INFORMATION PRIOR TO <br />CONSTRUCTION. THE CONTRACTOR SHALL, AT MINIMUM, CONTACT THE UNDERGROUND UTILITIES LOCATE <br />CENTER (811) TO HAVE UTILITIES VERIFIED ON THE GROUND PRIOR TO CONSTRUCTION. <br />3. THE TEMPORARY EROSION AND SEDIMENTATION CONTROL (TESC) MEASURES SHOWN IN THESE PLANS SHALL <br />BE CONSIDERED A MINIMUM. THE CONTRACTOR SHALL PROVIDE ANY REASONABLE ADDITIONAL MEASURES AS <br />MAY BE REQUIRED TO FACILITATE ACTUAL SITE RUNOFF CONDITIONS AT THE TIME OF CONSTRUCTION. ALL <br />NECESSARY EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE IN -PLACE PRIOR TO ANY <br />DEMOLITION OR CONSTRUCTION ACTIVITIES. <br />4. ALL NEW PAVEMENT, SIDEWALKS, AND CURB AND GUTTER INSTALLED BY THIS PROJECT SHALL BEAR ON <br />SUITABLE, COMPACT FOUNDATION SOILS IN ACCORDANCE WITH THE REQUIREMENTS OF THE STANDARD <br />SPECIFICATIONS AND PROJECT CONTRACT DOCUMENTS. SIMILAR EXISTING FACILITIES TO REMAIN, WHICH ARE <br />DISTURBED OR DAMAGED DURING CONSTRUCTION, SHALL BE REPLACED IN -KIND TO THE SAME STANDARDS <br />OF NEW FACILITIES. <br />5. ALL PAVEMENT MARKINGS SHALL CONFORM TO THE WSDOT STANDARD PLANS AND SPECIFICATIONS AS <br />AMENDED OR SUPPLEMENTED BY THE PROJECT PLANS, DETAILS, AND SPECIFICATIONS AS PROVIDED IN THE <br />CONTRACT DOCUMENTS. <br />6. ALL EXISTING ON -SITE WELLS OR SEPTIC TANKS SHALL BE PROPERLY ABANDONED BY A LICENSED <br />CONTRACTOR, CERTIFIED TO PERFORM SUCH WORK, AND WRITTEN VERIFICATION OF ABANDONMENT SHALL BE <br />PROVIDED TO THE OWNER, WASHINGTON STATE DEPARTMENT OF ECOLOGY, AND SNOHOMISH COUNTY HEALTH <br />DEPARTMENT IN ACCORDANCE WITH APPLICABLE AGENCY REGULATIONS. <br />Z THE MATERIALS AND METHODS OF INSTALLATION FOR ALL WATER AND SANITARY SEWER FACILITIES SHALL <br />BE IN ACCORDANCE WITH THE LATEST CITY OF EVERETT STANDARDS. <br />8. AT LEAST TWO COPIES OF THESE PLANS SHALL BE ON THE JOB SITE WHEN CONSTRUCTION IS IN PROGRESS. <br />THE CONTRACTOR SHALL ALSO HAVE COPIES OF THE APPLICABLE REGULATORY AGENCY STANDARDS <br />AVAILABLE AT THE JOB SITE DURING THE RELATED CONSTRUCTION OPERATIONS. ALL APPLICABLE PERMITS <br />SHALL BE OBTAINED PRIOR TO ANY CONSTRUCTION ACTIVITY. ONE COMPLETE SET OF PROJECT PLANS WITH <br />RECORDS OF AS -BUILT INFORMATION SHALL BE PROVIDED TO THE PROJECT ENGINEER AT THE END OF THE <br />PROJECT. <br />9. THE CONTRACTOR SHALL COORDINATE ACTIVITIES OF ALL UTILITY PURVEYORS IMPACTED BY WORK FOR THIS <br />PROJECT AND SHALL CONTACT THEM PRIOR TO CONSTRUCTION TO SCHEDULE WORK FOR PROVISIONS FOR <br />AND BE RESPONSIBLE TO SUPPORT, MAINTAIN, OR OTHERWISE PROTECT AND KEEP IN SERVICE ALL EXISTING <br />UTILITIES WHETHER SHOWN OR NOT SHOWN ON THESE PLANS DURING CONSTRUCTION. <br />10. UTILITIES, OR INTERFERING PORTIONS OF UTILITIES, THAT ARE ABANDONED IN PLACE SHALL BE REMOVED BY <br />THE CONTRACTOR TO THE EXTENT NECESSARY TO COMPLETE THE PROPOSED WORK. THE CONTRACTOR <br />SHALL PLUG THE REMAINING EXPOSED ENDS OF ABANDONED UTILITIES. CUTTING AND PLUGGING OF LINES TO <br />BE ABANDONED SHALL BE CONSIDERED INCIDENTAL TO OTHER WORK PERFORMED. <br />11. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL PROVISIONS OF THE SOILS <br />REPORT FOR THE SITE BE OBSERVED AND COMPLIED WITH DURING ALL PHASES OF SITE PREPARATION, <br />GRADING OPERATIONS, FOUNDATION, SLAB AND PAVING CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY <br />THE PROJECT ENGINEER IMMEDIATELY OF ANY PROVISION OF THE SOIL REPORT WHICH CONFLICT WITH <br />INFORMATION SHOWN ELSEWHERE ON THESE DRAWINGS, OR WHICH REQUIRES FURTHER CLARIFICATION. <br />12. THE OWNER SHALL OBTAIN THE SERVICES OF A QUALIFIED SOILS ENGINEER AND/OR TESTING AGENCY TO <br />PERFORM SUBGRADE/BACKFILL DENSITY TESTS OR TO DIRECT THE REMOVAL AND REPLACEMENT OF ANY <br />UNSUITABLE MATERIALS DURING CONSTRUCTION. A REPRESENTATIVE OF THE SOILS ENGINEER AND/OR <br />TESTING AGENCY SHALL BE AVAILABLE TO OBSERVE AND TO VERIFY FIELD CONDITIONS AS WORK PROCEEDS. <br />THE SOILS ENGINEER SHALL SUBMIT FIELD REPORTS AS REQUIRED TO CERTIFY THE METHODS AND <br />MATERIALS ARE IN ACCORDANCE WITH PROJECT SPECIFICATIONS. THE CONTRACTOR SHALL COORDINATE THE <br />APPROPRIATE SOILS INSPECTIONS AND TESTING. <br />13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE TRAFFIC CONTROL DURING <br />CONSTRUCTION ADJACENT TO OR WITHIN ALL PUBLIC ROADWAYS. TRAFFIC CONTROL MEASURES SHALL BE IN <br />PLACE PRIOR TO ANY CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL MAINTAIN ACCESS TO ALL PRIVATE <br />PROPERTY DRIVEWAYS DURING CONSTRUCTION. <br />CLEARING AND GRADING <br />A. ALL ENVIRONMENTALLY SENSITIVE AREAS AND THEIR BUFFERS SHALL BE FLAGGED FOR EASY IDENTIFICATION BEFORE <br />CLEARING TAKES PLACE. AFTER THESE AREAS ARE FLAGGED AND CLEARING LIMITS ARE APPROVED, AN AREA WIDE <br />ENOUGH TO INSTALL A SILT FENCE AT THE CLEARING LIMITS, BY HAND OR BY MECHANICAL METHODS, MAY BE CLEARED. <br />THE TOP OF THE SILT FENCE SHALL BE REFLAGGED AFTER INSTALLATION. IF A SILT FENCE IS NOT REQUIRED, THE AREA <br />SHALL BE DELINEATED USING AN ORANGE BARRIER. <br />B. ALL PERIMETER EROSION AND SEDIMENT CONTROL SHALL BE CONSTRUCTED, OPERATIONAL, AND INSPECTED BY THE <br />PUBLIC WORKS INSPECTOR PRIOR TO INITIATION OF CLEARING AND GRUBBING OPERATIONS. <br />C. DANGER TREES SHALL BE IDENTIFIED THROUGH A JOINT INSPECTION INVOLVING BOTH THE DEVELOPER AND PUBLIC WORKS <br />INSPECTOR. NO TREES SHALL BE REMOVED UNTIL PERMISSION IS OBTAINED FROM THE APPROPRIATE PARTIES. <br />D. WHERE POSSIBLE, NATURAL VEGETATION SHALL BE MAINTAINED FOR EROSION AND SEDIMENT CONTROL. <br />E. AS CONSTRUCTION PROGRESSES AND SEASONAL CONDITIONS DICTATE, THE EROSION CONTROL FACILITIES SHALL BE <br />MAINTAINED AND/OR ALTERED AS REQUIRED TO ENSURE CONTINUING EROSION/SEDIMENT CONTROL. <br />F. ALL TEMPORARY EROSION AND SEDIMENT CONTROL BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL <br />SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETED, PERMANENT DRAINAGE FACILITIES ARE OPERATIONAL, <br />AND THE POTENTIAL FOR EROSION HAS PASSED. <br />G. AT A MINIMUM, EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE MAINTAINED MONTHLY, OR FOLLOWING EACH <br />RUNOFF -PRODUCING STORM, TO ENSURE PROPER OPERATION OF ALL EROSION AND SEDIMENT CONTROL FACILITIES. <br />H. APPROVAL OF THIS PLAN DOES NOT CONSTITUTE AN APPROVAL OF DESIGN, SIZE, NOR LOCATION OF PERMANENT PIPES, <br />RESTRICTORS, OR DETENTION FACILITIES, BUT IS AN APPROVAL OF EROSION AND SEDIMENT CONTROL BMPS ONLY. <br />L THE PUBLIC RIGHT-OF-WAY SHALL BE KEPT CLEAN. TRACKING OF MUD AND DEBRIS FROM THE SITE WILL NOT BE <br />ALLOWED. FAILURE TO COMPLY WITH THIS CONDITION WILL RESULT IN ALL WORK ON THE SITE BEING STOPPED. <br />J. THE WASHINGTON STATE CLEAN AIR ACT REQUIRES THE USE OF ALL KNOWN, AVAILABLE, AND REASONABLE MEANS OF <br />CONTROLLING AIR POLLUTION, INCLUDING DUST. DUST CAN BE CONTROLLED BY WETTING EXPOSED SOILS, WASHING TRUCK <br />WHEELS BEFORE THEY LEAVE THE SITE, AND INSTALLING AND MAINTAINING ROCK CONSTRUCTION ENTRANCES. <br />CONSTRUCTION VEHICLE TRACKOUT IS A MAJOR SOURCE OF DUST AND ANY EVIDENCE OF TRACK -OUT CAN TRIGGER FINES <br />FROM THE DEPARTMENT OF ECOLOGY OR THE PUGET SOUND AIR POLLUTION CONTROL AGENCY. <br />K. EVERY EFFORT SHALL BE MADE TO CLOSE UTILITY LINES BY THE END OF THE DAY AND MATERIAL EXCAVATED DURING <br />UNDERGROUND UTILITY CONSTRUCTION SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES (WHERE CONSISTENT WITH <br />SAFETY AND SPACE CONSIDERATIONS). <br />STORM DRAINAGE <br />1. NO PART OF THE DRAINAGE SYSTEM SHALL BE COVERED, CONCEALED OR PUT INTO USE UNTIL IT HAS BEEN INSPECTED, <br />TESTED, AND ACCEPTED BY THE CITY OF EVERETT. <br />2. ALL WORK AND MATERIAL SHALL CONFORM TO THE CITY OF EVERETT STANDARDS AND STANDARD SPECIFICATIONS OF <br />WSDOT/APWA. <br />3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR <br />CONVENIENCE THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO <br />ANY ADDITIONAL UTILITIES SHOWN. IF CONFLICTS WITH EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE CONTRACTOR <br />SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE CITY ENGINEER <br />PRIOR TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. <br />4. ALL STORM SYSTEMS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS MUST BE STAKED BY SURVEY FOR LINE AND <br />GRADE PRIOR TO STARTING CONSTRUCTION. <br />5. ALL CATCH BASIN GRATES MUST BE STENCILED OR STAMPED 'BUMP NO WASTE, DRAINS TO STREAM, LAKE, RIVER, PUGET <br />SOUND, OR WETLAND." CHOOSE APPROPRIATE FEATURE FOR THE PROJECT. <br />A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF AN APPROVED BACKFLOW PREVENTION <br />DEVICE PRIOR TO SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND RECEIPT OF SATISFACTORY BACTERIOLOGICAL <br />TEST RESULTS <br />B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE CITY UTILITIES DEPARTMENT AT THE DEVELOPER'S <br />EXPENSE. THE CITY UTILITIES DEPARTMENT SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE FOR EACH CONNECTION. <br />THE CITY UTILITIES DEPARTMENT SHALL THEREAFTER DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION SHALL <br />BE MADE. <br />C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS. <br />D. A PRE -CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START OF CONSTRUCTION. THE CITY OF <br />EVERETT ENGINEERING DEPARTMENT CONSTRUCTION DIVISION MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />E. THE DEVELOPER OR THE DEVELOPERS AUTHORIZED AGENT SHALL NOTIFY THE CITY OF UTILITIES DEPARTMENT OF A <br />PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL SEPARATION BETWEEN POTABLE AND <br />NON -POTABLE CONVEYANCE SYSTEMS. <br />G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY CITY UTILITIES DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW <br />AND EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES. <br />SANITARYSEWER <br />A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS AND WSDOT/APWA STANDARD <br />SPECIFICATIONS. <br />B. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, CONCEALED OR PUT INTO USE UNTIL IT HAS BEEN <br />TESTED, INSPECTED, AND APPROVED BY THE CITY INSPECTOR. <br />C. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR <br />CONVENIENCE THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO <br />ANY ADDITIONAL UTILITIES NOT SHOWN. IF CONFLICTS WITH EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE <br />CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE <br />CITY ENGINEER PRIOR TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. <br />D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS MUST BE STAKED BY SURVEY FOR <br />LINE AND GRADE PRIOR TO STARTING CONSTRUCTION. <br />z <br />0 <br />a <br />m z <br />z z <br />0 <br />�, <br />Y <br />3 <br />CO <br />pp <br />U <br />3 <br />Of <br />aLU <br />rzdz <br />Go, <br />m <br />`� <br />FS .ati s r <br />OVAL <br />THE AS -BUILT INFORMATION <br />SHOWN ON THIS PLAN IS PER <br />A FIELD SURVEY PERFORMED <br />3Y MEAD GILMAN ASSOCIATES <br />AND/OR RECORD DATA <br />PROVIDED BY THE <br />CONTRACTOR. <br />CLIENT <br />z <br />C) <br />U <br />z <br />0 <br />C) <br />I <br />z <br />0 <br />z <br />z_ <br />x <br />3 <br />z <br />z <br />0 <br />U <br />x <br />i <br />0 <br />x <br />z <br />z <br />in <br />LL <br />Ld <br />w <br />Eu, <br />0 <br />I <br />TESC NOTES FOUR CORNERS, LLC <br />10900 NE 8TH STREET <br />1. APPROVAL OF THIS EROSION/SEDIMENTATION CONTROL (ESC) PLAN DOES NOT CONSTITUTE APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (E.G. SIZE AND LOCATION OF ROADS, PIPES, RESTRICTORS, SUITE 1200 <br />CHANNELS, RETENTION FACILITIES, UTILITIES). BELLEVUE, WA98004 <br />2. THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/CONTRACTOR UNTIL ALL PHONE: (425) 453-9551 <br />CONSTRUCTION IS COMPLETED AND APPROVED AND VEGETATION LANDSCAPING IS ESTABLISHED. <br />J. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS PLAN SHALL BE CLEARLY FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE <br />FLAGGED CLEARING LIMITS SHALL BE PERMITTED. THE FLAGGING SHALL BE MAINTAINED BY THE APPLICANT/CONTRACTOR FOR THE DURATION OF CONSTRUCTION. <br />4. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING AND GRADING ACTIVITIES, AND IN SUCH MANNER AS TO ENSURE THAT SEDIMENT AND SEDIMENT LADEN <br />WATER DO NOT ENTER THE DRAINAGE SYSTEM, ROADWAYS, OR VIOLATE APPLICABLE WATER QUALITY STANDARDS. C P H <br />5. THE ESC FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR <br />UNEXPECTED STORM EVENTS AND TO ENSURE THAT SEDIMENT AND SEDIMENT -LADEN WATER DO NOT LEAVE THE SITE <br />6. THE ESC FACILITIES SHALL BE INSPECTED ROUTINELY AND MAINTAINED BY THE APPLICANT CONTRACTOR TO ENSURE THEIR CONTINUED FUNCTIONING, ESPECIALLY AFTER STORM EVENTS. <br />7. EESC CIL171ES ON INACTIVE SITES SHALL BE SHALL MORE THAN ONE FOOT OF SEDIMENT BEALLOWED AND TO ACCUMNTAINED AULATE ATE WITHIN INIMUM OF ONCE <br />CTRAPPEDNCATCH BASIN. ALL TH OR WITHIN THE CA CATCHBASINSRS <br />G A MAJOR STORM EVENT <br />8. ATNO 71MECONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CONSULTANTS <br />CLEANING OPERATION SHALL NOT FLUSH SEDIMENT LADEN WATER INTO THE DOWNSTREAM SYSTEM. Site Planning • CNiI Engineering <br />9. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES MAYBE REQUIRED TO ENSURE Landscape Architecture •Land Use Consulting <br />THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT. <br />10. THE CONTRACTOR SHALL PROVIDE PERIODIC STREET CLEANING TO REMOVE DEBRIS AND SEDIMENT TRACKED OFF THE SITE CONTRACTOR SHALL KEEP CITY STREETS CLEAR OF DIRT AND DEBRIS AT ALL TIMES 11321-B NE 1201h Sheet <br />DURING CONSTRUCTION. DUST SUPPRESSION AND STREET CLEANING MUST OCCUR AS DIRECTED BY THE PUBLIC WORKS INSPECTOR. Kirkland, WA 98034 • (425) 285-2390 <br />11. APPROPRIATE MEASURES SHALL BE TAKEN TO STOP SEDIMENT FROM ENTERING SURFACE WATER BODIES IF THE PROPOSED BMPS FAIL. 101 South Wenatchee Avenue, Suite C3 <br />12. BARE AND/OR DISTURBED SOILS SHALL REMAIN UNCOVERED AND/OR UNSTABILIZED FOR NO MORE THAN 2 DAYS FROM OCTOBER 1 THROUGH APRIL 30, AND FOR NO MORE THAN 7 DAYS FROM MAY 1 THROUGH Wenatchee, WA 98MI-(509) 293-7731 <br />SEPTEMBERR 30. www.cph consult ants.com <br />PROJECT NO. <br />0024-18-042 <br />Copyright ® 2020 CPH Consultants, U.C. All Rlghts Reserved. <br />DRAWING <br />C0.01 <br />SHEET 2 OF 62 <br />