0 <br />SW 1/4, SEC. 07, TWP. 28N., R05E, W.M. CONSTRUCTION NOTES 0 <br />� 79THPLACE SE �vvvv vvvvvvvv � <br />PROJECT BOUNDARY (TYP.) EXIST 8" ov x x x x x x x <br />90 09 22.81 LT STA 24+20 26, 17 64 LT 4" DI WATER SERVICE AND METER PER COE STD. DWG. 504 > <br />91+00 (COLLECTOR ARTERIAL STA 24+20.29, (TO REMAIN 4 O " m <br />4- ®- - 792+00 193+00 ( 3 (1) 8"x6 DI TEE, FLxMJ CUT AND CONN. EXIST. 8 DI w/ 4 BACKFLOW ASSEMBLY (DCVA) PER COE STD. DWG. <br />o - ) -8" 194I oa (1) 8" DI LP SLEEVE5IMd 516, DCVA LOCATED WITHIN BLDG. MECH. ROOM, APPROX. z <br />-0 , - / (1) 8" PLU�JJ 1 " DI SPOOC,-LEWGTH AS-R . - PIPE LENGTH PER PLAN o <br />5 LF DI SPOOL / " (1) 8"x6" TAPPING 7EE, FL / w <br />14 2 1 6" GV, FLxMJ / O SAWCUT REMOVE AND REPLACE EXIST. PVMT. z z z <br />I (2) THRUST BLOCK ----- --- -- O x / / g z o o z <br />En i (1) 54 FH ASSEMBLY �° ( ) / / O PUBLIC WATER SYSTEMS, SEE C5.01 AND C5.02 it o v v <br />BUILDING TIP. / w ¢ o o2 En <br />z <br />1 OL -- -- - --- W W, w w W 4 FIRE HYDRANT ASSEMBLY PER COE S7D. DWG. 507, APPROX. M W > j Z 8 0 <br />SD S - ----- - <br />\ ✓ = D Ste- - �D- �D D - ry 5 3 D _ _-P APE _ - - 6" DI LENGTH PER PLAN z o > > IS Y <br />W a A RD R®�r�2� - RD ---RP RD rt R(r RD IRS-- RD �iB-� RO RD R.. o i Gam- cAsL aGAS AS g - F z w a-' �% <br />\ <:.. s O <br />-- <br />E. i E. i VALVE (PIV), WALL MOUNTED WHERE N 3 W to <br />\ s , D <br />O <br />� I I POST INDICATOR <br />4+0o g 50 F A - 5 SHOWN ON PLANS a a a¢ 0 z <br />3 3 3 W c�a 3 <br />Q • z4+ F 8 \ \ ' i O 6" FIRE DEPARTMENT CONN. (FDC) AND DI FIRE SPRINKLER z w m a o <br />F F° \\ SERVICE, LENGTH PER PLAN; SEE FIRE SYSTEM NOTES o 9 ¢ 9 9 W Y o <br />/ a APPROXIMATE LOCATION E. <br />- W <br />w L--- \ 10,00' GAS LINE ESMT m 3 m m m a W <br />/I --- ----- ----- ----- ----- ----- ----- ----- ----- ----- �SF \ REC. No. 200103060293 O7 ip IRRIGATION WATER SERVICE PER COE STD. DET. 501 wl m o m <br />%1 BACKFLOW ASSEMBLY DCVA PER COE STD. DET. 520; <br />CONTRACTOR TO INSTALL <br />• N V W <br />\ Ai o m w <br />12 5 \ o» �P O PUBLIC UTILITY EASEMENT m v n to <br />a aP • g a s a s 0 s «. " \ �_ 9O POTHOLE TO FIELD VERIFY LOCATION OF EXIST. WATER MAINOZ <br />dQ / as as as as <br />A: E n c.1 - c.1 0' \ I \ i -O �.o ° 10 BLOW OFF ASSEMBLY PER COE STD. DET. 511 <br />Ln <br />Q a <br />a o a = ° A a a 1" AIR VAC VALVE ASSEMBLY PER COE STD. DET. 512 <br />II II • . <br />ii it�� � 28050700306 0 <br />o RD �_ o DOUBLE CHECK DETECTOR ASSEMBLY DCDA IN VAULT PER <br />I ® + o SD SD e 2� SD 12 ( ) <br />C T / s o �V COE STD. DWG. 515; DCDA SIZE TO MATCH SERVICE, SEE <br />cN <br />FIRE SYSTEM NOTE 3 <br />C +' DRIVE L <br />��_�� 1 <br />� 13 PRIVATE FIRE SERVICE SUPPLY MAIN; SEE C5.03 AOs ONALfl <br />Q` <br />oQo �I a ® V • o f� A\ �'i / / 14 REUSE EXIST. DOMESTIC OR IRRIGATION WATER SERVICE AND <br />„ �I� O METER FOR NEW IRRIGATION SERVICE PER COE STD. DET. y <br />/ --- _-_-- _- -_ _- -_ _- - -_ _- J 7i �¢ A Q 13 501; INSTALL BACKFLOW DCVA PER COE STD. DET. 520, <br />I d ° -- -- - _- e U o � � c,n EXIST. SERVICE SIZE AND PIPE MATERIAL PER PLAN THE AS -BUILT INFORMATION <br />SHOWN ON THIS PLAN IS PER <br />c <br />D _aRD "TRo T -- as --tea Taa �T ro °'C.5 +� / k? LEGEND AFIELD SURVEY PERFORMED <br />" BY MEAD GILMAN ASSOCIATES <br />i � AND OR RECORD DATA <br />o g \ D k D - \ \ WATER METER AND SERVICE LINE PROVIDED BY THE <br />8+ 8. ® ® = CONTRACTOR. <br />FIRE DEPT. CONN. (FDC) <br />m / ° - - STA 99+06.9 9.55' Lt V �� ��� /\ z <br />� � � �' � (1 ♦ ASSEMB 1 � L o <br />e. J7+23.81 6. }�!1 UST --- - -- - ------ �1)-8"x4"-DL FIRE SERVICE <br />N--- - <br />m 4 1 5Y4" FH $ ---- - "-DI- - - ---------- -4 DI GV� L- --� - $ \\ aL -- 1 � z <br />H As l 1 THRUST BLOCK \ I 1 STORM DRAIN <br />o STA 9 +6 .25, 4. R. L 1 THRUST BLOCK �J° - O / + : \��. 23 00 3 - S o +0.40. 13.1 , LT g N - <br />o =130+ 0. 1 0 SITE A - 6" DI P00 J io SO CATCH BASIN <br />00 1 8" 5' DI BEND S 11 " x45- DI BEND /MJ $ e.n <br />O 1LF 8" DI LOCATE GOOSE NECK 8 F DI o 0 a° --- --- - - --- <br />1 1H US�f BLO K Z (1) THRUST E�LOC -- SS SANITARY SEWER MAIN z <br />o O Y�RD NTH I P N R \ s c. i $ �} m 1 N$8 4129 182. 6 0 <br />as a as a � as � as a as - \ ali I \ <br />44L�SEE 0 ) • - ' + E - - E E a _ E & a -- STD. PRECAST MANHOLE N <br />96 583 e e L J y 0 ------------------- - _ <br />-- 99+14. 4 12.4 $ �a a� as as as ------- g <br />�5L 1 o e r 51 <br />STA 3 I R + / SIDE SEWER SERVICE p <br />T ® x <br />(1) "x - BEND, ` E. 1 ' C M STA " e.4 ° °r r - - r - - - a SIDE SEWER CLEANOUT z <br />(1) R ST BLOC p E. ° rx caxwc owwn na na marx+ X�45' D' BEND, I a <br />- - - RUST BLOCK ° `s L <br />43F fI 8� D� ® W WATER MAIN <br />IJ � ° <br />o W 98+W W W W $ • / <br />96 71.0 . ° <br />9 STA �`O °0 ° a N� WATER SERVICE <br />lI - - s�sss ss s[ <br />(1) " D COU LIN SD F F F F F F F F F F F F F] r • / i p ---- PUBLIC UTILITY ESMT. <br />8" LENGTHVGi 8 <br />CON . �(ISF 1 - A / �� >� FIRE HYDRANT (FH) <br />S 10 6 V r a BACKFLOW ASSEMBLY (DCVA) <br />Q 1 <br />96 66.�3 1 I� / + • A + 1 88 V� <br />;�A �O-� <br />10 S - RD RD RD_ RD �� RD' w D1 RD $D RD ° . �n ti R . Ro 1 p';s i <br />-- - -- - -- -- -- L ti <br />", I .. :-� �---s" _ .. -----. - wily 'i�l' O i " Ili,, : ) '�� �/i��� w, II'�r�►� � /, III <br />I <br />I • � � � ,.IGi'����� � III . , � _ � , � V , �u I 1 II <br />®� DI BEND, Iwb <br />�y <br />THRUST BLOCK <br />imill <br />Ali III <br />, <br />`� �j ■I \L�� AII� ► II ; <br />_ • Dif BENI), MJ <br />III �C <br />RIM�liiiii�ii�lili�i��� <br />_ p _ • I *) <br />• daQi��ld'i N 4 . ,: W <br />I ''--- I I tdp LE i Boomi 1 <br />' <br />" <br />1 1 <br />N <br />0 30 60 <br />a <br />owwharsbelow. PLAN IN FEET <br />NOTES: <br />1. ALL WATER VALVES SHALL BE PROVIDED WITH VALVE BOX AND <br />OPERATING NUT EXTENDED PER COE STD. DWG. 505. <br />2. MEGA LUGS SHALL BE INSTALLED AT ALL BENDS AND FITTINGS <br />IN ACCORDANCE WITH COE STANDARDS. ALL PIPES AND <br />FITTINGS SHOWN AS RESTRAINED JOINTS (RJ) SHALL BE <br />MEGALUG GASKET OR APPROVED EQUAL. <br />3. DOMESTIC WATER SERVICE SUPPLY SHALL INCLUDE A DOUBLE <br />CHECK VALVE ASSEMBLY (DCVA) INSIDE BUILDING MECHANICAL <br />ROOM W/MATERIALS AND CLEARANCES PER COE STD. DWG. <br />520, REF. PROJECT PLUMBING PLANS/DETAILS. <br />4. THE CONTRACTOR SHALL VERIFY ALL SANITARY SEWER, <br />DOMESTIC WATER, AND FIRE SERVICE CONNECTIONS SHOWN ON <br />THIS PLAN WITH THE INFORMATION PROVIDED IN THE PROJECT <br />PLUMBING AND FIRE SPRINKLER PLANS/DETAILS AND NOTIFY <br />ENGINEER OF ANY VARIANCES PRIOR TO CONSTRUCTION. <br />5. ALL WATER MAIN PIPES SHALL BE DUC7ILE IRON, CLASS 52 <br />WITH A MINIMUM COVER OF 36" UNLESS OTHERWISE N07ED <br />AND APPROVED BY THE CITY. <br />6. COE WATER DEPT. CREWS SHALL MAKE ALL CONNECTIONS TO <br />ACTIVE PUBLIC WATER MAINS UNDER SEPARATE UTILITY PERMIT. <br />CONNECTION FEE SHALL BE BASED ON A COST ESTIMATE BY <br />THE WATER DEPT. AND WORK SHALL BE AT OWNERS EXPENSE. <br />WATER PURIFICATION TESTING SHALL BE COMPLETED PRIOR TO <br />CONNECTION. <br />7. EXIST. WATER METERS AND SERVICES NOT IN USE SHALL BE <br />REMOVED BY COE WATER DEPT. CREWS UNDER SEPARATE <br />UTILITY PERMIT. REMOVAL FEE SHALL BE BASED ON A COST <br />ESTIMATE BY THE WATER DEPT. AND WORK SHALL BE AT <br />OWNERS EXPENSE. <br />8. THE LOCATION OF THE YARD HYDRANT SHOWN IS <br />APPROXIMATE CONTRACTOR/OWNER SHALL DETERMINE FINAL <br />LOCATION AND SOURCE CONNECTION. YARD HYDRANT SOURCE <br />LINE MAY NOT CONNECT DIRECTLY TO PUBLIC WATER MAIN <br />AND SHALL BE INSTALLED AFTER PREMISE ISOLATION. <br />FIRE SYSTEM N07ES <br />0 <br />U <br />I..L <br />w <br />z <br />Z <br />o <br />O <br />cr <br />o z <br />ILL a <br />(� <br />L.L <br />� Q <br />3 <br />w <br />0 <br />cQ <br />ILL <br />p <br />L <br />U <br />CLIENT <br />FOUR CORNERS, LLC <br />10900 NE 8TH STREET <br />SUITE 1200 <br />BELLEVUE, WA98004 <br />PHONE: <br />(425) 453-9551 <br />1. FIRE SERVICE SUPPLY LINE SIZES SHOWN ARE APPROXIMATE. <br />ACTUAL LINE SIZES SHALL BE PER FIRE PR07ECTION ENGINEER. P <br />2. COE UTILITY SERVICES DEPARTMENT SHALL HAVE ACCESS TO <br />MECHANICAL ROOMS DURING THE HOURS OF 7: 30AM TO CONSULTANTS <br />4: OOPM, MONDAY THROUGH FRIDAY. Site Planning I, CNiI Engineering <br />3. FIRE SERVICE SUPPLY SHALL INCLUDE A DCDA IN AN EXTERIOR Landscape Architecture • Land Use Consulting <br />VAULT W/ A CITY APPROVED TRAFFIC RATED LID PER COE 11321-B NE IMth Sheet <br />STD. DWG, 515 AS SHOWN. ALL FIRE SPRINKLER SUPPLY LINES Kirkland, WA 98034 • (425) 285-2390 <br />AND APPURTENANCES SHALL BE INSTALLED PER COE DESIGN 101 South Wenatchee Avenue, Suite C3 <br />AND CONSTRUCTION STANDARDS AND SPECIFICATIONS. FIRE Wenatchee, WA 98MI-(509) 293-7731 <br />SPRINKLER SYSTEM DESIGN AND CONNEC71ON DETAILS SHALL www.cphcansuItants.cam <br />BE PROVIDED AND APPROVED UNDER SEPARATE PERMIT. PROJECT NO. <br />4. ALL PRIVATE FIRE SERVICE SUPPLY LINES SHALL MAINTAIN A 0024-18-042 <br />HORIZONTAL SEPARATION OF NOT LESS THAN 10 FEET AND <br />VERTICAL SEPARATION OF AT LEAST 18 INCHES FROM POTABLE DRAWING <br />WATER MAINS. SERVICENES SHALL <br />CROSS UNDER POITABLEFIRE WATER MAI SSUPPLY UNLESSL07HERMSE C5.01 <br />APPROVED BY THE CITY WITH ALTERNATE PROTECTIONS. <br />SHEET 36 OF 62 <br />Copyright 0 2020 CPH Consultants, I.I.C. All Rights Reserved. <br />