RECORD DRAWING MAY 2024 <br />153C <br />152C <br />■WEI <br />V) <br />Z) <br />.N <br />i <br />(D <br />n <br />i <br />O <br />O <br />O <br />n <br />V) <br />N <br />O <br />CT <br />Y <br />U <br />tZ <br />U <br />0 <br />490 <br />0 <br />10 <br />Lo <br />530 540 <br />530 <br />SDP-203 <br />25 LF 12" SD S=6.584% <br />- <br />0utMMIE:516.50, <br />--- <br />- <br />Sta:20+Rtt--[fi28rtrT__ <br />_ <br />--___ f <br />• <br />ioretention <br />520 <br />Cell A <br />520 530 <br />32 LF 8" SID <br />D S-0 005 <br />59 LF b S - <br />66 LF 4" <br />D S=0.005,, <br />.� <br />S=0.007 <br />SDCO-31 <br />6" Cleanout <br />SDCO-3 <br />o <br />MPT PVC Plug, <br />4" Clear <br />out <br />Aisle A 17+61.87 [-19.0' Lt] <br />MPT PVC <br />Plug, <br />CB Type-1 <br />Rim-521.94 <br />Aisle A 1 <br />+82.49 [-19.0' Lt] <br />510 <br />std grate,Std- - <br />r) �t-519 <br />- <br />510 52 <br />Aisle A 18+07.16 [10.2' Rt] <br />IE (6" o 19 <br />7 <br />IE (4" W) <br />ut=519.75 <br />Rimer-&6521.91 AB <br />SDP-32 <br />- <br />IE (12" W) in=-5+8-+5 SDCO-30 <br />14 LF 4" SD S=0.005 <br />- <br />IE (SSW) in=5+8-+5- 12" Cleanout <br />SDCO-32 <br />IE (12" NW) out--_,$- MPT PVC Plug, <br />4" Cleanout <br />(W)=518.13 AB Aisle A 18+20.74 [-19. <br />MPT PVC Plug, <br />500 <br />- -�-='�54 AR Rim=522.50 <br />Aisle A 17+48.2 <br />- <br />500 51 <br />(N)=518.13 AB IE (6" E) in=518.88 <br />Rim=521.77 <br />IE (8" NE) out=518.38 <br />IE (4" E) in=519.42 <br />IE (4" W) out=519.42 <br />493 <br />�o <br />L � <br />00 <br />coN <br />N <br />LO70 <br />LOLO <br />0+00 <br />1+00 <br />SOUTH LOTS EAST BASIN - <br />PROFILE <br />53 <br />52C <br />51C <br />50 <br />49 <br />Lot 12_ Lot 11 <br />Design Surface <br />SDP-12 SDP-11 <br />- <br />= <br />-49- LF 4" SD S =-9-095 3� LF 4" SD <br />S=0.005 <br />SDCO-12 <br />4" Cleanout <br />MPT PVC Plug, <br />Aisle D 41 +89.26 [-19.0' Lt] <br />IE (4" E) in=519.71 <br />IE (4" W) out=519.70 <br />SDCO-11 <br />4" Cleanout <br />MPT PVC Plug, <br />Aisle D 42+26.02 [-19.0' Lt] <br />I I�� <br />12" -Cleanout IE (4" W) out=519.89 <br />530 <br />520 <br />00 <br />495 <br />-� <br />o <br />C, <br />,d <br />r <br />I <br />�r01 <br />0 6 <br />�LO <br />LO�� <br />�� <br />1+18 1+00'1 <br />0+00 <br />NORTH LOTS - PROFILE <br />SCALE: Horz 1"=40' <br />F_ <br />(4:1) Vert 1 "=10' <br />I <br />i <br />493 <br />10 co <br />� LO <br />�o <br />LO� <br />50 <br />- <br />� <br />2+00 <br />2+54 <br />CN <br />N <br />J <br />EX/st/ng SUMCC& <br />----- <br />Design Surface <br />Bioretention <br />SDP-1(5 <br />SDP-5 0 <br />�r �. .... <br />i� a-92-LF 12" S D <br />101.64 AB <br />S=9-A9�.� 3$ LF�SD <br />0.0060 AB - �_ '- <br />O.OIo�R�---_ <br />SDCO-5 <br />12"-Cleano <br />SDCB-106 <br />SDCB-105 <br />CB Type-1 <br />CB Type-1 <br />std grate,Std <br />std grate,Std <br />N = 335623.3, <br />Aisle B 21 +04.25 [-10.0' Lt] <br />E = 1298762.3 <br />Rim 75+9-�&519.69 AB <br />Rim 518.93 AB <br />IE (12" N) in-C1T1 �J517.3 <br />IE (12" E) in -5+-6-.84 516.68 <br />B (6") AB IE (z E) in �i 517.46 <br />IE (6" NE) in=517.18 <br />AB IE (12" W) outer&517 <br />o <br />01 IE (6" SW) in=517.44 AB <br />00 <br />o <br />0 `_' <br />LO LO <br />SCALE: Horz 1 =40 1 +79 1 +00 <br />(4:1) Vert 1 ..= 10. <br />EAST LOTS TO CELL A - PROFILE <br />530 <br />520 <br />510 <br />Lot 10 Lot 9 Lot 8 Lot 7 Aisle B <br />J <br />U <br />Design Surface U <br />540 A PORTION OF SECTION 18, TOWNSHIP 28 NORTH, RANGE 05 EAST, W.M. <br />530 <br />520 <br />10 <br />AB <br />B <br />9 AB <br />00 <br />0 <br />0 <br />N <br />LO <br />0+00 <br />SCALE: Horz 1 "=40' <br />(4:1) Vert 1"=10' <br />Lot 6 Lot 5 Lot 4 <br />530 530 - <br />Lot 3 <br />530 <br />=0.021 31 LF 8, SD 0 <br />S-0 041 <br />59 LF 4" SD S=0.005 23 LF 33 F 4" <br />f_ <br />4" SD S 0.00 <br />SDCO-10 <br />4" Cleanout <br />��3 <br />CO-7 <br />_ ri <br />- - - - - - - - - - - - - - ---- S-�� _-_ _ _ --- - <br />MPT PVC Plug, <br />1 <br />��� <br />Pu t <br />SDCO-5 SDC -4 <br />Aisle B 23+01.73 [19.0' Rt] <br />PT PVC q 1_ �-- <br />12" Cleanout 4" Cl anout <br />isle B 22+14.48 [19.0' Rt] <br />MPT PVC Plug, g, MPT C Plug, <br />��ro��;7_ 1 <br />i <br />- -2- - <br />510 510 <br />7 B'Z7778 [19.0' Rt] -his e 20+87.7 [19.0- Rt] <br />510 <br />- <br />_ <br />I <br />(6" N) in=520.10 <br />Rim=520.35 Rim=520.44 <br />SDCO-9 <br />I <br />8" W out=519.60 <br />( ) <br />IE (4" S) in=518.68 IE (4" S) in=518. 0 <br />4" Cleanout <br />MPT PVC Plug, <br />SDCO <br />8 <br />IE (4" N) in=518.68 IE (4" N) out=518.80 <br />Aisle B 22+67.44 [19.0' Rt] <br />anout <br />IE (8" W) out=518.01 SDCO-3 <br />6" CI <br />Rim=524.1 1 <br />MPT P <br />C Plug, <br />SDCO-6 4" Cleanout <br />- IE (4" N) in=521 45 <br />A' I <br />22+50 37 19 0' Rt <br />4" Cleanout MPT PVC Plug, <br />500 <br />is e <br />IE (4" S) out=521.46 Rim=5 <br />�� <br />3.56 <br />500 500 <br />-Pvip vP, eB'Z0 .06 [19.0- Rt] <br />500 <br />SDP-9 IE (4" N) <br />in=521.01 <br />Aisle B 21+69.65 [19.0' Rt] Rim=520.74 <br />17 LF 4" SD S=0.026 IE (6" <br />) out=520.84 <br />Rim=520.96 IE (4" N) out= 19.08 <br />IE (4" S) out=518.97 <br />495 <br />495 495 <br />495 <br />o� <br />N� <br />N <br />L cop <br />c010 <br />c000 <br />CO <br />LOILO <br />L6 <br />c� <br />I LO LOILO <br />LO <br />LO <br />0 � <br />ILO <br />6 <br />L0 <br />0+00 <br />EAST LOTS 1- PROFILE <br />1+00 <br />1+70 0+00 1+00 1+47 <br />SCALE: Horz 1 "=40' EAST LOTS 2 - PROFILE SCALE: Horz 1 "=40' <br />(4:1) Vert 1 "=10' (4:1) Vert 1 "=10' <br />} Aisle D J <br />-------ram -� - - <br />-------------- -- -- <br />- <br />- <br />_------. - <br />Tract 99$ 55 <br />Bioreten tl on Cell A C21 <br />- <br />- <br />Design Surface <br />- <br />- <br />---- --- <br />----- <br />8-7- LF 18' S•D S=O-n0�r 0.007 <br />85.6 A <br />N <br />- <br />Aisle �' <br />Bioretention <br />- <br />- <br />_ <br />__14 <br />- <br />SDP_ 14 <br />5 LF 4" Sp <br />S=0.029 <br />SDCO-13 <br />9 LF8"S 120.35 <br />S=0.007 - <br />�-102 <br />�+ LF 12' SD S=440} 0.0152 <br />SDCB-103 0 0 <br />CB Type-1 <br />std grate,Std <br />N = 335625.7, <br />0 <br />0 <br />DP -AO <br />LF 12" S <br />- <br />EXrst gSuria <br />/n c <br />---- ----__ -- <br />Cell <br />___---0 <br />2 - --_ <br />5�Q-� 34 LF 6" Perf <br />n',�� <br />I <br />0 <br />0 0 0 0 0 0 0 0 0 0 0 0 <br />SDP- <br />1 16.75 AB HIE <br />0 <br />0 <br />__ <br />AB <br />0 0 <br />e S=0.005 <br />1 <br />AB <br />1 2" �IPnnni it <br />MPT PVC Plug, <br />Aisle D41+40.16 [-19.0'Lt] - <br />Rim=521.74 - <br />IE (4" W) in=519.46 1+40. <br />IE (4" E) in=519.46 im- <br />IE (8" S) out=518.79 <br />_ <br />SDCO-14 <br />4" Cleanout <br />MPT PVC Plug, <br />Aisle D 41+04.75 [-19.0' Lt] <br />Rim=521.96 <br />IE (4" E) out=520.47 <br />E = 1298735.50.0317AB <br />Rim=C1�519.06 AB SD <br />IE 12" N in-51-6.91 516.81 AB <br />rate ( ) 6" <br />IE N in-61 �T 517.42 AB <br />2 [0.0'] {' ) MPT <br />6" AB <br />.26 AB N = <br />(") 518.72 AB Rim <br />518.65 AB IE (1 <br />�Cul <br />-A01 SDCB-A02SDCB-A03 <br />leanout 54" Type 2 - Ctrl Strci <br />PVC Plug, Atrium grate,Std <br />35624.9,E = 1298703.2 Aisle A 18+12.00 [28. <br />518.50 Rim-520.69 A <br />"SE) out=512.96 IE (12" NW) in= <br />IE (12" SE) out- <br />48" Type 2 <br />Solid Lid,StdAisle <br />' Rt] Aisle A 18+00.08 [9.9' Rt] <br />Rim=32 4 521.58 AB <br />512.61 AB IE (12" NW) in=511.84 AB <br />512.56 AB �E ink <br />IE (12" E) out 4 511.82 A <br />I <br />- <br />SDCB-506 <br />.0025 AB 48" Type 2 3� • 0.0� <br />CB-505 SDC -B02 B <br />Solid Lid,Std <br />"-Type 2 54" Type 2 - Ctrl Strctr <br />A 15+28.57 [21.5' Rt] Atri m grate,Std SDCO-BO1 <br />Rim -5r - 518.51 AB AislE A 15+22.71 -16.5' Lt <br />IE (18" NW) in=-599-09 [ ] 6" Cleanout _ <br />Rim �8-518.69 AB MPT PVC Plug, <br />IE 1�S in�09-09 � g' - n-r n nn 510 A_^`^TCTS�CI�� l- <br />��- -- <br />IE (18" E) out09-09 IE (1 " N) out-61 2.00 Rim=517.50 <br />(NW) 508.83 AB 512.09 AB IE (6" E) out=512.17 <br />(S) 509.10 AB <br />(E) 508.83 <br />79.33 AB <br />- S <br />rsDCB-504 4 <br />48"-T e 2 <br />yp <br />td <br />52 <br />_ <br />ut= <br />o LO <br />C4 d <br />LO <br />10 - <br />10 <br />LO <br />� � <br />co CN Co <br />LO <br />� <br />Lo <br />�r <br />LO <br />o ni <br />LO LOIFO <br />O0 <br />o, <br />LO <br />m <br />o, n <br />70 <br />0+00 <br />BIOCELL AB - PROFILE <br />FNOTE: Restrictor Assembly <br />per Std. Dwg 415 &416 <br />Rim EL=SI3.38 <br />AB <br />R/serToo <br />EL74 <br />- <br />512.96 AB <br />1+00 <br />Debris Cage <br />Ladder / Steps <br />N <br />12" Outlet <br />Out/et Shear /2"117/e1 <br />EL f9 8 g � EL 3AQLLq <br />51 1.22 A B 51 1.22 A B <br />24" <br />Control Structure and <br />Supports: <br />Yx0.090", 2' O.C. max. <br />RestnctorP/ate with 24" <br />shop dui//edo)7f/ce <br />Diameter=6.0"A e <br />E= �4 Type-1 L per <br />509.19 B ° ° DCSS 413 <br />SECTION THROUGH PIPES <br />SDCB-FR2 <br />FR2 <br />SCALE: NTS <br />2+00 <br />NOTE: Restrictor Assembly <br />per Std. Dwg 415 &416 <br />FLAN <br />3+00 <br />ebris Cage <br />R/m EL=S20.6P <br />AB <br />R/serTop <br />EL=,+A97r <br />519.56 AB <br />AB <br />Orifice Diameter: 0.50" <br />Elev: �0' o <br />519.06 AB ° N <br />a N <br />12" Outlet <br />Out/et Shear �- /2"117/e1 <br />EL8 g� EL8 <br />512.56 AB 512.61 AB <br />24 -Ladder/Steps <br />Control Structure and <br />Supports: <br />Yx0.090", 2' O.C. max. <br />RestnctorP/a/e W11b 24" <br />shop d1i//edo17f/ce 54" <br />D/ametei, =2. 32S" A Ie <br />E/=3/B.J a ° <br />511.06 AB <br />SECTION THROUGH PIPES <br />o SDCB-A02 Control Structure <br />SCALE: 1 "=3' <br />4+00 <br />NOTE: Restrictor Assembly <br />per Std. Dwg 415 &416 <br />530 <br />520 <br />490 <br />0 <br />0 <br />6 <br />N <br />LO <br />5+00 6+00 7+00 7+26 <br />SCALE: Horz 1 "=40' <br />(4:1) Vert 1"=10' <br />Rim EL=S18.6P Debris Cage <br />AB <br />RisefTOO <br />EL=Szi?38- <br />517.64 AB <br />Ladder / Steps <br />Ln <br />a N <br />12" Outlet <br />Out/et Shear 6"/n/et <br />EL=�h?� <br />512.09 AB 512.04 AB <br />24" <br />Control Structure and <br />Supports: <br />Yx0.090", 2' O.C. max. <br />Rest17C101 /ate w//h 24" ° <br />shop dj//ed o�f/ce 54" <br />D/ameter6.0"A e <br />E/=✓tB 8 a ° <br />510.14 AB <br />SECTION THROUGH PIPES <br />g0 SDCB-B02 Control Structure <br />SCALE: 1 "=3' <br />1 53 <br />1 52 <br />1 51 <br />5C <br />49 <br />0+00 <br />EAST LOTS -PROFILE <br />1+00 <br />■ ■® <br />530 <br />520 520 <br />510 510 <br />500 500 <br />490 490 <br />O N <br />0 <br />o `_ <br />N LO <br />L <br />Contractor to provide <br />outlet at CB w/ IE equal to <br />520 <br />- - <br />520 <br />520 <br />or less than Overflow Riser <br />520 <br />Rim El with positive <br />discharge to tract, away <br />from Aisle. (IE EL=513) <br />' SDP `� <br />-------- <br />33.25�BF C <br />j <br />SDP <br />1 <br />510 <br />- <br />- <br />LF 1�" <br />510 <br />510 <br />T - <br />0 2 'LF 12" <br />SD <br />510 <br />_ <br />------ <br />0.0196 A <br />��� <br />0.00 <br />464- <br />DSP-OVF C <br />SDCB EX1 <br />SDP-FR2 <br />SDCB-FR229 <br />- - <br />S CB-EX� <br />2" Standpipe 48'Ty 2 <br />olid Lid, <br />21.39-2 <br />AB LF 12" <br />CB Type-1 L SD S=6-6&5 <br />_ <br />48"Typ i <br />isle A 12+87.92 [-14. 1' Lt] <br />Ctrl Strctr 0.0491 AB <br />stdg�a Std <br />500 <br />=" 51 �- <br />- <br />500 <br />500 <br />Atrium grate,Std SDCB-FR1 <br />msi Ln 7� i Iyp7-r <br />RiM- 514.19 AB <br />7F'J`ll <br />WAB <br />E (12" N) out=5 11.24 510.54 AB <br />(Approx. Bend) <br />Rim -5+3-0&513.38 AB Solid Lid,Std <br />_ <br />_ 1E/12"S/in=AW..i9i 50189 <br />AB <br />IE (6" W) in=5+e.25 Aisle A 12+64.44 [4.9 <br />-2t] <br />y W/out=389z, <br />9.85 AB <br />495 <br />495 <br />IE (12" N) out=510.25 Rim -3 5 513.64 A <br />adt-512. <br />1 0 <br />LO <br />00 <br />0 <br />511.22 AB IE (12" S) in=5+6-i 5-5 <br />0.17 AB <br />o <br />Ni <br />°N° <br />IE (12" E) in=5iE)H55 5 <br />9.95 AB <br />"O <br />LO <br />"O <br />LO <br />IE (12" NW) out=5+0-�& <br />490 <br />fobt- <br />�� <br />490 <br />-0+ 15 0+00 <br />0+90 <br />BIO-CELL C OVERFLOW SCALE: Harz 1"=40' <br />- PROFILE (4:1) Vert 1"=10' <br />485 <br />485 <br />00 <br />; <br />Fn 509.95 AB <br />0+00 <br />1+00 1+59 <br />BIO-CELL C - PROFILE SCALE: Horz 1"=40' <br />(4:1) Vert 1 "=10' <br />Design <br />- <br />-- - - - - - --- <br />SDP-506 <br />_ <br />- <br />$DP-508 --__ <br />,6-7-LF 18" SID S=A S <br />_ 60 LF 6" Perf S=0.005 <br />64.45 AB 0.0051 AB <br />- SDCO-509 <br />SDCB-506 <br />_ 6" Cleanout <br />48"-Type 2 <br />- MPT PVC Plug, <br />N = 335554.9, E = 1299099.0 <br />SDCB-507 <br />_ <br />- Rim=513.55 <br />CB T�cpe=L- <br />std grate,Std <br />DCB-508 <br />Aisle A 14+49.60 [37.8' Rt] <br />B Type-1 <br />Rim=C1�512.82 AB <br />trium grate,Std <br />IE (18" W) in 508.50 AB <br />isle A 14+49.98 [56.9' Rt] <br />_ IE (12" N) out=56B.516 508.50 A B <br />F <br />im=-S- -512.07 AB <br />-_ SDP-507 <br />I <br />(12" S) in=508.39AB <br />= 508.85 A B <br />.0 20.57 AB 0.0054 A BO� <br />10 <br />L <br />06 <br />70 L0 <br />L0 <br />2+00 2+27 0+00 1+00 <br />SCALE: Horz 1"=40' (4:1) Vert 1"=10' LEVEL SPREADER -PROFILE <br />UNDERGROUND UTILITY NOTE <br />Underground utility locations shown hereon are based <br />upon surface indicators. No underground location <br />service was utilized for their location. The use of this <br />map for their exact location is not warranted. Prior to <br />construction user should call the utility location service <br />at 1-800-424-5555 48 hours before construction. <br />530 5 <br />520 5 <br />510 5 <br />500 5 <br />490 4 <br />jU <br />Lot 2 Lot 1 <br />20 24 <br />C19 C'esign Surface <br />Proposed Level <br />Spreader <br />_SDP-1 <br />33LF4"SD <br />10 -� zDL'� fisting 5 <br />4" Cleanout lfaay <br />MPT PVC Plug, - <br />N = 335465.0, - <br />E = 1299346.9 - <br />Rim=515.92 - <br />IE (4" W) out=513.50 <br />D _ <br />4" Cleanout <br />MPT PVC Plug, <br />N = 335465.6, <br />E = 1299313.5 <br />Rim=515.50 <br />SDP-2 IE (4" E) in=513.17 <br />? 22 LF 4" SD S=0.01 1 IE (4" W) out=513.17 <br />OC) ICY) <br />c <br />N N L6 Lr <br />Lo Lo �: <br />30 <br />20 <br />10 <br />00 <br />90 <br />1+66 0+98 0+00 <br />SCALE: Horz 1"=40' LOTS 1 2 -PROFILE SCALE: Horz 1"=40' <br />(4:1) Vert 1 "=10' (4:1) Vert 1 "=10' <br />N <br />O <br />N <br />LU <br />01 <br />- <br />s <br />� <br />oQ <br />0 <br />LLJ <br />U <br />o <br />Z � <br />N <br />�4,N <br />Q <br />O, <br />Q > N <br />LO <br />7C) '10 <br />O <br />L <br />� <br />~ C C'7 <br />C) <br />0,4 <br />00 Q <br />00 <br />i r <br />• <br />C <br />,1k #7 <br />l <br />IIIIII„dIIIIL„......„ <br />■ <br />--� y• <br />r <br />, <br />RECORD DRAWING <br />This Record Drawing has been prepared, in part, based on <br />information gathered during construction and historical <br />documents. Although the information and this drawing are <br />basedLgn the best available information, no presumption <br />b e regarding the drawing's accuracy. <br />igned By Date <br />TYLER FOSTER, P.E. <br />Print Name and Title <br />* RIPRAP: Crushed or Broken Rock <br />meeting WSDOT 9-13.4(2) Class A <br />"well -Graded" (or equivalent) <br />- - - - - - - - - - CLASS -A - - - - - - - - - <br />Approx Size [1] <br />Percent Passing <br />----f,nY----L---(smallerj--- <br />18.000 1 <br />100.000 <br />_ <br />16.000 <br />-95 <br />-------------- <br />12.000 <br />50-80 <br />8.000----i <br />-_-_-_-15-50---- <br />--- <br />4.000 r <br />15 max. <br />[1 ] Approximate Size is determined by the <br />following calculation: <br />Size = (Length + Width + Thickness)/3 <br />Top of Bubble- Up to be no Atrium Grate on <br />higher than bottom of Type] CB <br />Riprap <br />bioretention cell rock bed <br />Extreme Storm events <br />Discharge to will discharge <br />existing stormwater via <br />Channelized Surface Flow <br />drainage course <br />O� O u e oc r\ \ <br />0 /\\/\\ <br />e I \�1\ / <br />./1 /\ \\ � .TKO To\ \\ \\ \\ \ <br />S �e // / / �n s '�'/ <br />r <br />the t� ��\ <br />di <br />location <br />24 LEVEL SPREADER OUTFALL <br />SCALE: 1 "=2' <br />w <br />0 <br />w <br />Z <br />00 <br />Q <br />o <br />00 <br />0� <br />Q <br />_ <br />O <br />'- <br />} <br />N <br />N <br />Z <br />0J <br />a- <br />w <br />w3 <br />z <br />O <br />LU <br />J <br />a� <br />Q <br />-C <br />~ <br />ao <br />O <br />� <br />U <br />} <br />0 <br />o <br />T <br />Z <br />O <br />IL <br />� <br />U <br />w <br />z <br />Q <br />O <br />O <br />Z <br />F_ <br />M <br />Q <br />0 <br />J <br />Q <br />LJJ <br />Q <br />O <br />N <br />V) <br />U <br />op <br />V) <br />J <br />J <br />Q <br />Q <br />LJJ <br />N <br />-C <br />J <br />m <br />o <br />m <br />I <br />V) <br />Q <br />3 <br />} <br />N <br />N <br />U <br />w <br />' <br />•- <br />-C <br />SHEET <br />C19 of C27 <br />24x36 <br />REV1122-047 <br />P W 2303-015 <br />