Laserfiche WebLink
RECORD DRAWING MAY 2024 <br />A PORTION OF SECTION 18, TOWNSHIP 28 NORTH, RANGE 05 EAST, W.M. <br />V) <br />iD <br />N <br />(D <br />iD <br />V) <br />-0 <br />J <br />aD <br />(D <br />n <br />0 <br />E <br />0 <br />0 <br />n <br />V) <br />N <br />E <br />0 <br />0 <br />Y <br />U <br />U <br />RECORD DRAWING <br />This Record Drawing has been prepared, in part, based on <br />information gathered during construction and historical <br />documents. Although the information and this drawing are <br />based on the best available information, no presumption <br />sh e regarding the drawing's accuracy. <br />05 03 2024 <br />Wined By Date <br />TYLER FOSTER, P.E. <br />Print Name and Title <br />O <br />0 <br />0 <br />0 <br />z <br />a <br />0 <br />0 <br />0 <br />z <br />Z <br />0 <br />06 <br />z <br />0 <br />to V <br />d � <br />os <br />VrvN\i <br />3/4" OR 1" METERED WATER SERVICE <br />MAX RAKE, 1/4" PER FT <br />FROM GROUND LEVEL <br />NOTES <br />A. ROMAC, FORD, OR MUELLER SERVICE SADDLE WITH C.C. THREAD TO BE USED ON ALL MAINS 4" DIA. AND <br />LARGER. ALL NEW TAPS ON EXISTING WATER MAINS SHALL BE DONE BY THE CITY OF EVERETT UTILITIES <br />DEPARTMENT AT THE DEVELOPERS OR CONTRACTORS EXPENSE <br />B. CORPORATION STOP: <br />3/4" OR 1" - FORD FB600, OR CITY APPROVED EQUAL <br />C. FORD SERIES LAO-2-33S NL FOR 3/4" OR LA02-44S-NL FOR 1" BEND FITTING (1/8 OR 1/4) FOR FLARE x FLARE <br />COPPER. PHYSICAL BENDS IN POLYETHYLENE PIPE ARE NOT ALLOWED. USE APPROPRIATE 1/4 OR 1/8 BENDS PER <br />NOTE B ABOVE. <br />D. USE MUELLER H-15073 N INSTA-TITE FITTING OR CITY APPROVED EQUAL FOR IPS-PE PLASTIC PIPE X FEMALE <br />COPPER FLARE THREAD. <br />E. RESIDENTIAL SERVICE: <br />cc <br />LU 1. PROVIDE 3/4" OR 1" POLYETHYLENE TUBING MEETING THE FOLLOWING REQUIREMENTS: <br />o a. AWWA C901. <br />z b. ASTM D2239, SIDR 7, FOR ID IRON PIPE SIZE (IPS). <br />c. ASTM 3350 - PE3608 OR PE4710. <br />N 2. PROVIDE A #10 AWG, SINGLE STRAND COPPER WIRE WITH BLUE TYPE OF OR USE COATING SUITABLE FOR <br />DIRECT BURY. <br />a. WRAP WIRE AROUND TUBING, ONE WRAP PER FT, ITS ENTIRE LENGTH. <br />b. SECURE ONE END AROUND THE SADDLE BOLT BETWEEN TWO NUTS AND EXPOSE A MINIMUM OF 18" OF THE <br />OTHER END IN THE METER BOX. <br />F. NON-RESIDENTIAL SERVICE: <br />LJJ <br />Z <br />N <br />�4�1N <br />� Q o. <br />> � <br />Q �Ln <br />co <br />O � <br />N •� <br />00 Q <br />00 <br />• <br />53726 <br />REC/STER�o <br />S 0NALEN <br />05/03/2024 <br />N <br />0 <br />N <br />co <br />01 <br />01 <br />t <br />Q <br />O <br />U <br />0 <br />d' <br />N <br />I I I I <br />L Q w <br />N � <br />_J <br />W <br />O <br />J � O � O <br />o° ~ ry <br />''' z Q C z CL <br />U <br />U U CL 0CLLU <br />U Q V—) Q <br />0 = LU � CL � w p <br />CL 0 0 0 cn Q Q <br />1. PROVIDE 3/4" OR 1" TYPE K COPPER TUBING MEETING ASTM B88, ANSI/NSF 61 & APPLICABLE IAPMO <br />STANDARDS. <br />G. USE 1/4 OR 1/8 BEND BRASS ST BEND WITH MUELLER H-15426 N INSTA-TITE FITTING OR CITY APPROVED EQUAL <br />FOR IPS-PE PLASTIC PIPE X MALE IRON PIPE THREAD. <br />H. 3/4" METER SETTER SHALL BE "A.Y. MCDONALD" 62-212WWDD33-15 OR APPROVED EQUAL. <br />Cl) <br />1" METER SETTER SHALL BE "A.Y. MCDONALD" 62-415WWDD44-15 OR CITY APPROVED EQUAL. <br />W <br />LO <br />I. METERS SHALL BE SUPPLIED AND INSTALLED BY CITY UTILITIES DEPARTMENT AT THE DEVELOPERS OR <br />C) <br />CONTRACTOR EXPENSE. <br />LU <br />0 <br />J. PROVIDE METER BOX BODY MANUFACTURED BY "RAVEN PRODUCTS, FOR A 3/4" USE MODEL RMB-11-18-12, <br />00 z <br />FOR A 1" USE MODEL RMB-15-27-12", MOUSEHOLES CUT, WITH AASTHO H-20 RATED DI FLUSH SOLID COVER <br />c/i 0 M <br />LID OR EQUAL. <br />00 _ <br />0, <br />K. PLACE SAWDUST IN METER BOX AROUND PIPE TO TOP OF METER TO PREVENT FREEZING. <br />T11 Q M <br />3� O <br />._ <br />} <br />W 00 <br />CITY OF EVERETT <br />W <br />= <br />PUBLIC WORKS DEPARTMENT <br />u!i z <br />City Engineer [ awn Current Rev Date <br />SR.-HEFTI �APAULWILHELM <br />v ' <br />ger ger y <br />WRB 09/18/2017TIT <br />LE RYAN SASS <br />(/') j O <br />STANDARD DRAWING Na. <br />METERED WATER SERVICES <br />Q <br />3/411 & 111 501 <br />-C 00 <br />T <br />U 0 O <br />0, F— <br />U <br />LLJ <br />PARTS <br />p <br />A. HYDRANTS AND ALL MATERIALS SHALL CONFORM TO <br />z <br />0 <br />AWWA STANDARDS AND SHALL BE OF STANDARD <br />MANUFACTURE (MUELLER SUPER CENTURION #250, <br />~ <br />M <br />WATEROUS PACER #WB67, OR CITY APPROVED <br />EQUAL). <br />Q <br />B. 5-1/4" VALVE MINIMUM. <br />C. 1-1/4" OPERATING NUT AND CAP NUT FOR 2-1/2" <br />PORTS. <br />D. NATIONAL STANDARD THREAD ON 2-1/2" PORTS. <br />E. 5" STORZ FITTING WITH NATIONAL STANDARD THREAD <br />ON THE 4-1/2" PORT. <br />C <br />I <br />F. IF HYDRANT RISES THROUGH CONCRETE, USE <br />E <br />EXPANSION STRIP AROUND HYDRANT BARREL, PER STD <br />PLAN 509. IN ADDITION, INSTALLATION OF THE <br />HYDRANT ON PRIVATE PROPERTY SHALL EQUAL OR <br />EXCEED THE STANDARDS FOR INSTALLATION OF <br />TRAFFIC SAFETY <br />PUBLIC FIRE HYDRANTS IN THE CITY OF EVERETT. <br />CV <br />FEATURE BREAK -OFF <br />VALVE BOX AND EXTENSION PER <br />STANDARD DRAWING 505 <br />G. PROVIDE FOR VEHICULAR TRAFFIC PROTECTION WHEN <br />U <br />3 <br />FLANGE, BREAK OFF <br />NUTS AND BOLTS <br />NECESSARY PER STANDARD DRAWING 508. <br />J <br />00 <br />�\ j\ <br />H. STEAMER PORT TO BE FACING STREET OR ROADWAY <br />J <br />Q <br />FOR FIRE ENGINE ACCESS. <br />— <br />1/2 CU YD WASHED ROCK <br />F J <br />I. BREAK -OFF FLANGE TO BE 2"-4" ABOVE GROUND <br />C <br />0 <br />1 1/2" DRAIN ROCK <br />DUCTILE IRON TEE <br />LEVEL. <br />co <br />RETAINER <br />(MJxMJxFL) OR <br />Q <br />GLANDS <br />TAPPING TEE (FL) <br />J. INSTALL CONCRETE PAD AROUND HYDRANT IN <br />O <br />�� <br />UNPAVED, SOD AND ASPHALT AREAS PER STANDARD <br />DRAWING 508. <br />\\\ <br />\/ <br />\ <br />— <br />K. HYDRANT CONNECTION PIPE TO BE DUCTILE IRON <br />(� <br />T11 <br />V) <br />j <br />a <br />CLASS 52, ANY INTERMEDIATE JOINTS TO BE M1 WITH <br />RETAINER GLANDS, OR FIELD LOCK GASKETS. <br />_ <br />%�� <br />\ i <br />\\ <br />L. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS <br />•— <br />K <br />OF HIGH GLOSS CATERPILLAR YELLOW, LUXLITE <br />#6100-516 OR "RUST-OLEUM" #7448 OR APPROVED <br />U <br />N <br />w <br />Z <br />Z <br />CONCIBLOCK <br />GATE VALVE <br />EQUAL. THE PORT CAPS WILL BE PAINTED BLACK. <br />•— <br />d <br />2 <br />(MJ x FL) <br />M. PROVIDE FOR A MINIMUM OF 3' CLEAR ZONE AROUND <br />• — <br />} <br />w <br />p <br />6 MIL PLASTIC SHEETING WRAP <br />HYDRANT. <br />m <br />0 <br />ED <br />UNDISTURBED EARTH <br />0� <br />0 <br />z <br />0 <br />CITY OF EVERETT <br />Z <br />PUBLIC WORKS DEPARTMENT <br />p <br />w0 <br />Clty Engineer ager ger a n Y Current Rev Date <br />RYAN SASS R HENI CAPAUL WILHELM w WRB 5/9/2018 <br />TITLE <br />yU' <br />r <br />w" <br />00 <br />STANDARD DRAWING No. <br />FIRE HYDRANT <br />Q <br />INSTALLATION 507 <br />J <br />Q <br />L.0 <br />n <br />ry <br />L.0 <br />Q <br />m <br />I <br />V) <br />Q <br />SHEET <br />C26 of C27 <br />24x36 <br />REV1122-047 <br />P W 2303-015 <br />