Laserfiche WebLink
3 <br />I <br />PERE P <br />SECTION 13, TOWNSHIP 28N, RANGE 4E, W.M. <br />00378700200501 <br />9515 HOLLY DRIVE <br />EVERETT, WA 98204 <br />N. <br />2.� <br />I <br />r <br />, <br />1 <br />� <br />l C3 <br />f <br />j <br />4 <br />\° <br />a f . <br />i <br />r 4 <br />�/ <br />T <br />2.6 <br />i — <br />a <br />x. <br />\ <br />u <br />, <br />G r i i <br />;f <br />- $6- - \. 4 <br />T <br />j 4 P <br />s <br />jA <br />6 \ \ a€ <br />J INGRESS EGRESS J \ <br />f & UTILITY EASEMENT <br />.,_.. <br />DJ, "WATER MAIN 7'BUFFE4 <br />20' WATER EASEMENT <br />AND VACATED.967H STREET S (AB)(7) 1" WATER METER (TYP.) I \ <br />AEN 960JO70450 PER STD. DWG. 501 <br />(SEE DET. SHT. 9) <br />EX 2--1I=5 <br />1E=58t.50(S12"CC,NCj `" --. . <br />00378700303700 <br />MUKILTEO SCHOOL ~ "" -. <br />9401 SHARON DR EX, CB-T1=5S.Z14..,,j <br />EVERETT, WA 98204 'E=580.06(NE12"Dr) <br />tE=580.24{502'0"/)1 <br />� <br />WATER STANDARD NOTES: <br />A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF AN APPROVED <br />BACKFLOW PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND <br />RECEIPT OF SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br />B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE PUBLIC WORKS DEPARTMENT <br />AT THE DEVELOPER'S EXPENSE. THE PUBLIC WORKS DEPARTMENT SHALL BE GIVEN AT LEAST 5 <br />BUSINESS DAYS NOTICE FOR EACH CONNECTION. THE PUBLIC WORKS DEPARTMENT SHALL THEREAFTER <br />DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION SHALL BE MADE. <br />C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS. <br />D. AN ON -SITE PRE -CONSTRUCTION CONSULTATION SHALL BE HELD WITH THE CITY PUBLIC WORKS <br />INSPECTOR PRIOR TO THE START OF CONSTRUCTION. THE CITY OF EVERETT PUBLIC WORKS <br />INSPECTOR MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />SEE PERMIT FOR INSPECTION SCHEDULING INSTRUCTIONS. <br />E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY THE PUBLIC WORKS <br />DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS DURING CONSTRUCTION <br />ON A 24 HOUR BASIS. <br />F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL SEPARATION BETWEEN <br />POTABLE AND NON -POTABLE CONVEYANCE SYSTEMS. <br />G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS DEPARTMENT PERSONNEL <br />ONLY. ALL VALVES, NEW AND EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES. <br />/ <br />/ <br />/ <br />/ <br />\$ /- <br />EX SSMH=584. 74 --_ <br />00378700200500 IE-575,636NWE PVC). 7� - - - cam <br />9520 HOLLY DRIVE <br />EVERETT, WA 98204 IE-575,76{NW6-PVC) <br />/ <br />EVER - <br />1E=57 44(Sr8"PYCy% <br />15' ESM'T <br />TO MWWD / <br />AF#202110060383 & / / EX SSMH=-584.19 <br />20220303157 // JE=571.45(W87PVC) / <br />tE- 571.33(NE8'1}'VC.� <br />/? p <br />EX. WATER METER <br />TO BE REMOVED/ <br />1 ABANDONED r <br />(SEE NOTE) <br />,O 1px <br />px <br />j <br />EX. <br />i" H <br />/ EX. <br />/ rH <br />EX. CB-T7-583:71 <br />IF=581.74(L81PVC) - <br />r <br />/ A f 6" TAPPING TEE <br />gp 3q-6" G.V. (RJxFL) <br />9 LF 6" RJDI <br />1-HYD. ASSY.(AB) <br />EX. C.q--71=563.59 PER COE STD. DWG. 507 <br />IE=58"8(" PVC) THRUST BLOCKING <br />IE=580.93(SWt2 D1) (SEE NOTE) <br />AS -BUILT NOTE: <br />EXISTING WATER METER NOTE: <br />A CITY OF EVERETT WATER DEPARTMENT CREW <br />SHALL BE RESPONSIBLE FOR REMOVING THE <br />EXISTING WATER METER ON LOT 1 AND <br />CAPPING THE SERVICE LINE IN THE PUBLIC <br />RIGHT OF WAY. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR DISCONNECTING THE <br />SERVICE BEHIND THE WATER METER (ON THE <br />PRIVATE SIDE) AND REMOVING THE EXISTING <br />SERVICE ON LOT 1. <br />NOTE: <br />6" TAPPING TEE CONNECTION TO BE <br />PERFORMED BY CITY OF EVERETT WATER <br />DEPARTMENT UNDER A SEPARATE UTILITY <br />PERMIT BASED ON A COST ESTIMATE <br />PROVIDED BY THE WATER DEPARTMENT AND <br />PAID FOR BY THE OWNER/CONTRACTOR. <br />RECORD DRAWING <br />This Record Drawing has been prepared, in part, <br />based on "As -Built" information provided by <br />others. Though the as -built information and this <br />drawing are based on the best available <br />information, no presumption should be made <br />regarding the drawing's accuracy. <br />Jim Knappert 01/17/2024 <br />Permit Inspector <br />THE AS -BUILT INFORMATION SHOWN WAS <br />PROVIDED BY ORCA LAND SURVEYING, INC., & <br />THE CONTRACTOR. OMEGA ENGINEERING HAS <br />PREPARED AND STAMPED THIS DRAWING BASED <br />ON THAT INFORMATION. <br />N <br />0����40 <br />HORIZONTAL SCALE <br />J <br />QAO <br />Know what's below. <br />Call two business <br />days before you dig. <br />} <br />m <br />Z <br />0 <br />a <br />U <br />U) <br />W <br />0 <br />W <br />Q co RT <br />LU Q O L0 <br />0 0) N <br />LJO L0 <br />V V <br />LU LU L w w <br />Lu <br />o w <br />N <br />^ <br />M <br />I <br />Z <br />O <br />Z <br />a <br />�/ I <br />N� <br />�� <br />Q <br />frj <br />LQL.I <br />WN <br />16ow <br />()Z <br />xU) <br />WW <br />W°W <br />Z <br />O <br />} <br />w <br />N <br />U <br />O <br />a <br />22-0104 EJT <br />8/11/2022 <br />V,=20' <br />8 or 9 <br />