Laserfiche WebLink
0 <br />0 <br />0 <br />N <br />co <br />>N <br />U <br />W_ <br />U) <br />0 <br />0 <br />0 <br />U) <br />r) <br />U <br />U <br />H <br />u1 <br />u1 <br />2 <br />0 <br />Q <br />U <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />N <br />co <br />N <br />^N <br />L n <br />2._ <br />M(U LL <br />W <br />M M <br />co co <br />275 <br />(Da <br />0� <br />..� <br />V­ N <br />N 0 <br />N <br />C7 0 <br />CITY OF EVERETT WATER NOTES <br />1. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED <br />EXCEPT BY MEANS OF AN APPROVED BACKFLOW PREVENTION <br />DEVICE PRIOR TO SATISFACTORY FLUSHING, TESTING, <br />DISINFECTION, AND RECEIPT OF SATISFACTORY <br />BACTERIOLOGICAL TEST RESULTS. <br />2. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE <br />BY THE PUBLIC WORKS DEPARTMENT AT THE DEVELOPER'S <br />EXPENSE. THE PUBLIC WORKS DEPARTMENT SHALL BE GIVEN <br />AT LEAST 5 BUSINESS DAYS NOTICE FOR EACH CONNECTION. <br />THE PUBLIC WORKS DEPARTMENT SHALL THEREAFTER <br />DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION <br />SHALL BE MADE. <br />3. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF <br />EVERETT STANDARDS. <br />4. APRE-CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY <br />PRIOR TO THE START OF CONSTRUCTION. THE CITY OF EVERETT <br />PUBLIC WORKS CONSTRUCTION DIVISION MUST BE NOTIFIED AT <br />LEAST 24 HOURS PRIOR TO COMMENCEMENT OF <br />CONSTRUCTION. <br />5. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED <br />AGENTSHALL NOTIFY THE PUBLIC WORKS DEPARTMENT OF A <br />PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS <br />DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />6. MAINTAINING A MINIMUM OF 10 FEET HORIZONTAL AND 18 <br />INCHES VERTICAL SEPARATION BETWEEN POTABLE AND <br />NON -POTABLE CONVEYANCE SYSTEMS <br />7. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC <br />WORKS DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW AND <br />EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES. <br />KNOW WHAT'S BELOW <br />CALL BEFORE YOU DIG <br />811 <br />callbeforeyoudig.org <br />A PORTION OF THE SW 1/4 OF SECTION 02, T 28 N, R 04 E, W.M. <br />CONSTRUCTION NOTES <br />0 INSTALL: <br />A. 1-16" 8" TAPPING TEE AND TAPPING GATE VALVE PER COE STD <br />514 <br />B. THRUST BLOCK <br />BY COE WATER CREW AT DEVELOPERS EXPENSE. COORDINATE WITH <br />THE CITY WATER DEPT. AT LEAST TWO WEEKS IN ADVANCE <br />(425-257-8827). EXISTING MAIN LOCATION SHALL BE FIELD VERIFIED. <br />2O INSTALL: <br />A. 1-8" 8" TEE, MJ MJ FL <br />B. 1-12" GATE VALVE, MJ <br />C. 1-12" 8" REDUCER, MJ FL <br />D. 2-8" GATE VALVES, FL MJ <br />E. THRUST BLOCK <br />QINSTALL: <br />A. 1-2" DOMESTIC WATER METER AND SERVICE PER COE STD 522. <br />B. 25 LF 4" DOMESTIC WATER SERVICE FROM METER TO BLDG <br />O <br />INSTALL: <br />A. 1-8" 6" TEE, MJXMJXFL <br />B. 1-8" ISOLATION GATE VALVE, FLXMJ <br />C. 1-22.50 BEND, MJXMJ <br />D. THRUST BLOCK <br />O5 INSTALL: <br />A. 1-8" 6" TEE, MJ FL <br />B. 1-FIRE HYDRANT ASSEMBLY PER COE STDS 507 508. <br />C. THRUST BLOCK <br />OBACKFLOW PREVENTION AND DCDA TO BE PROVIDED WITHIN <br />BUILDING IN DESIGNATED RISER ROOM WITH DOOR TO EXTERIOR PER <br />COE STD 523. <br />INSTALL: <br />A. WALL MOUNTED PRESSURE INDICATOR VALVE (PIV). SEE <br />MECHANICAL PLANS FOR STD. DETAILS. <br />B. INSTALL REMOTE FIRE DEPT. CONNECTION (FDC) WITHIN 75' OF <br />HYDRANT. <br />C. 2- BOLLARDS <br />O7 INSTALL: <br />A. 1-8" 22.50 BEND, MJ MJ <br />B. THRUST BLOCK <br />O8 INSTALL: <br />A. 1-8" 450 BEND, MJ MJ <br />B. 1-8" GATE VALVE, MJ MJ <br />C. 1-THRUST BLOCK <br />OINSTALL: <br />A. 8" TEE, MJ FL <br />B. 2-8" GATE VALVES, MJ MJ <br />C. 1-8" GATE VALVE, FL MJ <br />D. THRUST BLOCK <br />SINSTALL: <br />A. 1-11.250 BEND, MJ MJ <br />B. THRUST BLOCK <br />11 INSTALL: <br />A. 2" IRRIGATION METER AND SERVICE PER COE STD 502. <br />B. DCVA PER COE DETAIL 520 <br />12 INSTALL: <br />A. 1-450 BEND, MJ MJ <br />B. THRUST BLOCK <br />GINSTALL:: <br />A. 1-16" 8" TAPPING TEE AND TAPPING GATE VALVE PER COE STD <br />514 <br />B. THRUST BLOCK <br />14 INSTALL: <br />A. 2-8" 450 BEND, MJ MJ <br />B. 1-THRUST BLOCK <br />BY COE WATER CREW AT DEVELOPERS EXPENSE. COORDINATE WITH <br />THE CITY WATER DEPT. AT LEAST TWO WEEKS IN ADVANCE <br />(425-257-8827). EXISTING MAIN LOCATION SHALL BE FIELD VERIFIED. <br />SCALE <br />50 0 25 50 100 <br />(FEET) <br />1 INCH = 50 FT. <br />DAVID EVANS <br />ANDASSOCIATES INC. <br />1620 W. Marine View Drive <br />Suite 200 <br />Everett, WA 98201 <br />425.259.4099 <br />r <br />W <br />H <br />Z <br />W Cj) <br />U(.9 <br />J Z <br />Q <br />UQ <br />W � <br />0 0 <br />U <br />U <br />a <br />W <br />Z <br />� J <br />�a <br />cl) <br />OC <br />m W <br />Zaco <br />F_ <br />F_ <br />W <br />W <br />W <br />W <br />LL <br />O <br />F_ <br />A <br />RECORD <br />DRAWINGS <br />CHECKED BY: JNS <br />DESIGNED BY: AC <br />DRAWN BY: VM <br />FIRST SUBMITTAL DATE: 10/31/20241 <br />PROJECT NO. <br />281200000004 <br />SHEET NO. <br />�� I Cl 2mO <br />