Laserfiche WebLink
A PORTION OF THE SW 114 OF SECTION 02, T 28 N, R 04 E, W.M. <br />I) <br />v <br />0 <br />0 <br />0 <br />CV <br />W <br />5 <br />C0 <br />0 <br />i <br />MCTI <br />T <br />T <br />A <br />1R <br />Z <br />.~0 <br />2 <br />00 <br />SN <br />CV <br />m <br />c <br />m m <br />QQ <br />mm <br />�75 <br />n <br />vv <br />IT <br />(0(0 <br />CV Q <br />MO) <br />SHEAR GATE <br />GROUT (TYP) <br />12" INLET PIPE <br />STANDARD <br />HDPE STEPS <br />FINISHED GRADE <br />(MAX. WATER SURFACE) <br />18" DIAMETER RISER <br />PIPE SUPPORT: 3"X0.9 GA. <br />BOLTED OR EMBEDDED 2" IN <br />WALL AT MAX. 3" SPACING. <br />SECURE RESTRICTOR TO CATCH <br />BASIN WITH 8 GAUGE ALUMINUM <br />STRAPS AND BOLT TO CATCH <br />BASIN WALL WITH STAINLESS <br />STEEL ANCHOR BOLTS. ONE <br />STRAP ABOVE AND BELOW <br />OUTLET REQUIRED. <br />IE:501.70 <br />1 12" OUTLET PIPE <br />WELD 12 GA. BOTTOM PLATE WITH <br />0.95" ORIFICE, SHARP EDGE, <br />SHOP DRILLED IN PLATE. <br />KNOW WHAT'S BELOW <br />CALL BEFORE YOU DIG <br />811 <br />callbeforeyoudig.org <br />18" RISER <br />PLAN VIEW <br />OUTLET OF TEE SECTION SHALL BE <br />SMOOTHED WALL METAL PIPE WITH <br />OUTSIDE DIAMETER 4" LESS THAN INSIDE <br />DIAMETER OF CONNECTING PIPE <br />12" OUTLE PIPE <br />ROUND, SOLID, LOCKING LID MARKED <br />"DRAIN" WITH LOCKING BOLTS <br />N <br />ROUND, SOLID, LOCKING LID MARKED <br />"DRAIN" WITH LOCKING BOLTS <br />FG=515.34 <br />RECTANGULAR NOTCH <br />NOTCH HEIGHT = 1.562' <br />NOTCH WIDTH = 0.021' <br />STANDARD <br />STEPS OR <br />LADDER <br />220 CAPACITY <br />ALUMINUM LIFT <br />ROD,SECURE <br />TO STEP <br />CLEANOUT WITH 8" <br />SHEAR GATE <br />12" INLET PIPE <br />SECTION VIEW <br />54" CATCH BASIN <br />FLOW RESTRICTOR - CS 1 <br />PER CITY OF EVERETT STD DTL 415 <br />SCALE: 1 "=2' <br />E: 501.70 <br />RECORD DRAWING <br />This Record Drawing has been prepared, in part, <br />based on "As -Built" information provided by <br />others. Though the as -built information and this <br />drawing are based on the best available <br />information, no presumption should be made <br />regarding the drawing's accuracy. <br />Jim Knappert 10/22/2024 <br />Permit Inspector <br />02'4" [610] <br />ACCESS <br />N <br />coFLOW <br />w <br />FD <br />12'4" [36581 <br />4'4" [12191 T-O" [9141 <br />ACCESS OPENING <br />I� � III IIII <br />_ II - <br />II <br />II - <br />I� I I II <br />IL � I I II <br />II II II 111 <br />PLAN VIEW <br />(MEDIA NOT SHOWN FOR CLARITY) <br />MANHOLE FRAME AND COVER <br />SUPPLIED BY CONTECH <br />0 <br />Z <br />'0- <br />o <br />oU) <br />M LLJ <br />U <br />a <br />ACCESS HATCH <br />SUPPLIED BY CONTECH <br />CONTRACTOR TO PROVIDE <br />GRADE RINGS/RISERS, SLAB <br />TO MEET FINISHED GRADE <br />N <br />PVC INLET I- -_---1 IF -1 <br />ASSEMBLY - <br />-- I <br />INLET 1 INVERT I c' I <br />ELEV.501.50' <br />= I II <br />PROVIDED INLET I® �y-� <br />PIPE STUB (012") I <br />I II II L j <br />------------J- <br />SEDIMENT BAFFLE <br />FACET MPAK MEDIA <br />ELEVATION VIEW <br />VortClarex° <br />PVC OUTLET <br />ASSEMBLY <br />VCL60-1 DESIGN NOTES <br />VCL60-1 RATED TREATMENT CAPACITY IS 225 GPM [14.19 1/9), OR PER LOCAL REGULATIONS. IF THE SITE CONDITIONS EXCEED RATED <br />TREATMENT CAPACITY, AN UPSTREAM BYPASS STRUCTURE IS REQUIRED. <br />THE VORTCLAREX SYSTEM SHALL REMOVE ESSENTIALLY ALL FREE AND DISPERSED NON -EMULSIFIED OIL FROM THE WATER STREAM <br />AND PRODUCE A DESIRED EFFLUENT BASED ON AN OIL DROPLET TYPICAL OF THE SITE. <br />THE VORTCLAREX SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH STOKES LAW AND API BULLETIN NO.421. <br />THE STANDARD INLET/OUTLET CONFIGURATION IS SHOWN. FOR OTHER CONFIGURATION OPTIONS, PLEASE CONTACT YOUR CONTECH <br />ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com <br />24" [610] FRAME AND COVER 36" x 48" [914 x 1219] ACCESS HATCH <br />(ACTUAL PRODUCT MAY VARY) (ACTUAL PRODUCT MAY VARY) <br />N.T.S. N.T.S. <br />SITE DESIGN DATA <br />WATER QUALITY FLOW <br />0.08 CFS <br />RATE <br />PEAK FLOW RATE <br />1.51 CFS <br />RETURN PERIOD OF <br />100 YRS <br />PEAK FLOW <br />I <br />GENERALNOTES <br />[1 <br />1. <br />CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. <br />2. <br />FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH <br />ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com <br />OUTLET 1 INVERT N <br />3. <br />VORTCLAREX WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED <br />ELEV.501.50' ro <br />IN THIS DRAWING. CONTRACTOR T" CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. <br />4. <br />STRUCTURE SHALL MEET AASHTO HS20 AND CASTINGS SHALL MEET AASHTO M306 LOAD RATING, ASSUMING GROUNDWATER <br />Q <br />ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER <br />PROVIDED OUTLET io <br />ELEVATION <br />_ <br />PIPE STUB (012") <br />5. <br />INLET AND OUTLET PIPES MUST BE PERPENDICULAR TO THE VAULT TO ALLOW CONNECTION WITH PROVIDED PIPE STUBS. <br />6. <br />FLOW LINE IN AND OUT OF THE VORTCLAREX IS RECOMMENDED TO BE AT THE SAME ELEVATION. <br />PERMANENT <br />7. <br />ALTERNATE UNITS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. <br />POOL ELEV. <br />INSTALLATION NOTES <br />1. <br />ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND <br />SHALL BE SPECIFIED BY ENGINEER OF RECORD. <br />2. <br />CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE VORTCLAREX <br />STRUCTURE (LIFTING CLUTCHES PROVIDED). <br />3. <br />CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. <br />4. <br />CONTRACTOR TO PROVIDE AND INSTALL FERNCO, OR EQUIVALENT, COUPLER TO MATE EXISTING TRUNKLINE TO THE PROVIDED <br />PIPE STUBS. MATCH PIPE INVERTS WITH ELEVATIONS SHOWN. <br />SITE SPECIFIC DATA <br />c L <br />PROJECT NUMBER <br />719899 <br />WETLANDMEDIA <br />BED <br />- - - - - - - - - - , <br />i::.' I <br />VERTICAL <br />UNDERDRAIN <br />PROJECT NAME <br />SEAWAY COMMERCIAL CENTER <br />1 <br />,;.�:; <br />''9 . '.„ ' ':, :,.::..: <br />MANIFOLD <br />PROJECT LOCATION <br />EVERETT, WA <br />PATENTED <br />TREATMENT REQUIRED <br />PERIMETER <br />I <br />,' •: � <br />I <br />VOID AREA <br />VOLUME BASED (CF) <br />FLOW BASED (CFS) <br />1 <br />-,. <br />0.08 <br />PEAK BYPASS (CFS) - (12 CFS MAX ALLOWED) <br />1.06 <br />PIPE DATA <br />I.E. <br />MATERIAL <br />DIAMETER <br />INLET PIPE- <br />❑ <br />OUTLET PIPE <br />INLET PIPE 501.20 PVC 12 SEE NOTES <br />OUTLET PIPE 498.49 PVC 12" <br />PRETREATMENT BIOFILIRA TION DISCHARGE <br />RIM ELEVATION 515.58 515.58 515.58 <br />SURFACE LOAD HS-20 HS-20 HS-20 <br />FRAME & COVER 030" 030" N/A <br />WETLANDMEDIA VOLUME (CY) 1.36 <br />ORIFICE SIZE (DIA. INCHES) 01.44" <br />NOTES: 30" LIDS SHALL BE HINGED AND CAPABLE OF BEING <br />OPENED AND HELD OPEN BY A SINGLE INDIVIDUAL. <br />ALTERNATIVELY, LID MAY INCLUDE AN INNER 24" ACCESS LID. <br />INTERNAL BYPASS DISCLOSURE: <br />THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED <br />AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE <br />ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS <br />CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. <br />INSTALLATION NOTES <br />1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT, MATERIALS AND <br />INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND <br />APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE <br />MANUFACTURERS SPECIFICATIONS, UNLESS OTHERWISE STATED IN <br />MANUFACTURERS CONTRACT. <br />2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER <br />RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY <br />THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE FOR VERIFYING 50' <br />PROJECT ENGINEERS RECOMMENDED BASE SPECIFICATIONS PEAK <br />4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING 501 <br />PIPES ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF IE <br />CONCRETE (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF <br />OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. <br />ALL PIPES SHALL BE SEALED WATERTIGHT PER MANUFACTURERS <br />STANDARD CONNECTION DETAIL. <br />5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL PIPES, RISERS, <br />MANHOLES, AND HATCHES. CONTRACTOR TO USE GROUT AND/OR <br />BRICKS TO MATCH COVERS WITH FINISHED SURFACE UNLESS SPECIFIED <br />OTHERWISE. <br />6. CONTRACTOR RESPONSIBLE FOR CONTACTING CONTECH FOR ACTIVATION <br />OF UNIT MANUFACTURERS WARRANTY IS VOID WITHOUT PROPER <br />ACTIVATION BY A CONTECH REPRESENTATIVE. <br />GENERAL NOTES <br />1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED. <br />2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACIAES ARE SUBJECT TO <br />CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS <br />AND ACCESSORIES PLEASE CONTACT CONTECH. <br />F- SEE NOTES <br />PLAN VIEW <br />TOP of <br />GRADE RINGS <br />H <br />OLU <br />z� <br />to <br />(D <br />LU <br />of <br />�of <br />C/L <br />505.28 <br />roP of BOX <br />I <br />1 <br />1 I <br />1 I <br />I 1 I <br />50 <br />YGL ' <br />I <br />�0 <br />N 1 FLOW CONTROL <br />' RISER <br />1 <br />1 <br />1 I <br />--- 498.49 <br />lE OUT <br />6" 4'-0"_6" <br />5'-0" <br />ELEVATION VIEW <br />MANHOLE <br />In RIGHT END VIEW <br />PROPRIETARY AND CONFIDENTIAL: <br />M O TLA�NDR THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE <br />PROPERTY OF FORTERRA AND ITS COMPANIES. THIS DOCUMENT <br />FOR PATENT INFORMATION, GOTO NOR ANY PART THEREOF, MAY BE USED, REPRODUCED OR MODII <br />­OontechES.com/IP <br />RMATION,P IN ANY MANNER WITH OUT THE WRITTEN CONSENT OF FORTERRA <br />C74 NTECH® <br />ENGINEERED SOLUTIONS LLC <br />www.CoMechES.com <br />6"- <br />LEFT END VIEW <br />TREATMENT FLOW (CFS) 0.09 <br />OPERATING HEAD (FT) 26 <br />PRETREATMENT LOADING RATE (GPM/SF) 1.6 <br />WETLAND MEDIA LOADING RATE (GPM/SF) 1.0 <br />M W54-4-8-6'--0 "- V- UG <br />STORMWATER B/OFILTRATION SYSTEM <br />STANDARD DETAIL <br />RECORD DRAWINGS <br />DATE: 09-26-2024 <br />� a <br />® 0 <br />DAVID EVANS <br />ANDASSOCIATES INC. <br />1620 W. Marine View Drive <br />Suite 200 <br />Everett, WA 98201 <br />425.259.4099 <br />LLU <br />r <br />Z <br />w� <br />U � <br />J Z <br />Q <br />U/ Q <br />LU <br />Q <br />0 0 <br />U <br />>- LU <br />LU <br />F_ <br />W <br />W <br />W <br />LL <br />0 <br />H_ <br />U <br />RECORD <br />DRAWINGS <br />?-k-56 <br />Col <br />Q4 og WAs� <br />ri. <br />20111114 <br />i.�0� �GISTERti9 <br />CHECKED BY: JNS <br />DESIGNED BY: AC <br />DRAWN BY: VM <br />FIRST SUBMITTAL DATE: 09/26/2024 <br />PROJECT NO. <br />281200000004 <br />SHEET NO. <br />C1000 <br />