Symbol Legend GENERAL NOTES CODE INFORMATION MOUNTING HEIGHTS g
<br /> 0
<br /> �M
<br /> SYMBOL DESCRIPTION MANUFACTURER MODEL QUANTITY 1. FIRE ALARM SYSTEM IS POWER LIMITED. BUILDING CODE 2018 INTERNATIONAL BUILDING CODE (B) A/C SUPPLY 3N
<br /> WITH WASHINGTON STATE AMENDMENTS DIFFUSER
<br /> Pss 6AMP, 120VAC REMOTE CHARGER POWER SUPPLY RED ENCLOSURE SILENT KNIGHT SK-PS6 1 2. ALL RACEWAYS MUST BE FREE OF MOISTURE. 3'(MIN) FLUORESCENT rq-�
<br /> 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE 2018 WASHINGTON STATE ENERGY CODE CEILING LIGHT N
<br /> Q? LOW-PROFILE PHOTOELECTRIC SENSOR WHITE SILENT KNIGHT SK-PHOTO-W 1 MOUNTING ELECTRICAL BOXES. ///U�
<br /> NATIONAL FIRE PROTECTION ASSOCIATION 2018 NATIONAL FIRE ALARM CODE (NFPA 72 CEILING MOUNTED 3'� 4 NE
<br /> ❑M INTERFACE MODULE, ADDRESSABLE SILENT KNIGHT MONITOR 3 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM ) SMOKE/HEAT NOT q" v 11
<br /> o
<br /> WIRING. AUDIO/MSUAL OEIECTOR PERMITTED PERMITTED 1Y
<br /> ® RELAY MODULE, ADDRESSABLE SILENT KNIGHT RELAY 3 2023 NATIONAL ELECTRICAL CODE (NFPA 70) &VISUAL ONLY HERE HERE MAx
<br /> 5. UNRELATED (NON-FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY ® FlRE~DEMCES p 1i
<br /> AS FIRE ALARM WIRE. WITH INTERNATIONAL FIRE CODE (TNT 5'�
<br /> ® STROBE, CEILING, RED SYSTEM SENSOR SCREED 5 WITH wasHlNGroN srATE AM ENOMENrs
<br /> 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL f'� MAGNETIC 1
<br /> el 2-WIRE, HORN STROBE, CEILING, RED SYSTEM SENSOR PC2RLED 3 BACKBOX FOLLOWING POWER-LIMITING AND NON POWER-LIMITING WIRING SYNCHRONIZE MORE DOOR 1 Npo
<br /> REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE OCCUPANCY CLASSIFICATIONS - B/S-1 THAN TWO VISUAL HOLDER Y, p
<br /> INFORMATION. APPLIANCES IN ®° N 3
<br /> (2) STROBE, CEILING, WHITE SYSTEM SENSOR SCWLED 9 ANY FIELD of MEW FACP 3
<br /> 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. 6"01 rn 3
<br /> BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED 80"MIN J 3 ro
<br /> 2-WIRE, HORN STROBE, CEILING, WHITE SYSTEM SENSOR PC2WLED 7 CIRCUITS. T-TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. ® 3 Z
<br /> 96"MAX
<br /> -AA, GENERIC EOL 4.7K GENERIC GEOL4.7K 4 8. PEE TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR MANUAL1 O NN
<br /> SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 66"AFF PULL �.
<br /> ❑F E PULL STATION, DOUBLE ACTION, ADDRESSABLE SILENT KNIGHT SK-PULL-DA 1 9. ALL FIRE ALARM WIRING SHALL TEST FREE of OPENS, SHORTS, AND STATION
<br /> GROUNDS 48'MA
<br /> . X(ADA)
<br /> ❑M E INTERFACE MODULE, ADDRESSABLE SILENT KNIGHT MONITOR 1 42-MIN/s4"MAX(NFPA) N
<br /> 10. ALL WIRING SHALL BE LABELED AND TAGGED. FINISHED FLOOR a
<br /> Q E DUAL MONITOR MODULE SILENT KNIGHT MONITOR-2 3 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRICAL CODE •DEMCES SHOWN DEPICT DEVICE TYPES ONLY.
<br /> o? E SMOKE, PHOTOELECTRIC, ADDRESSABLE SILENT KNIGHT PHOTO 2 ARTICLES FOR FIRE ALARM AND LOW-VOLTAGE WIRING.
<br /> 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET.
<br /> Psi E CAME, 120VAC REMOTE CHARGER POWER SUPPLY RED ENCLOSURE SILENT KNIGHT SK-PS6 1
<br /> FACP E FACP ADDRESSABLE 198 OR 318 POINTS SILENT KNIGHT 5808 1 FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. SYSTEM OUTPUTS
<br /> AUBURN, WA
<br /> ® E L-SERIES STROBE, RED, WALL SYSTEM SENSOR SRL 1 253-859-2000 FACP ANNUNCIATION NOTIFICATION
<br /> qZ�IE L-SERIES 2-WIRE, HORN STROBE, RED, CEILING SYSTEM SENSOR PC2RL 6 FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC.
<br /> AUBURN, WA �OQ' � O�
<br /> 01E L-SERIES 2-WIRE, HORN STROBE, RED, CEILING SYSTEM SENSOR PC2RL 5 EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. PSO� O�GP V'0 y'\P�� OCR
<br /> NORTHFORD, CT O� 11 �pQ' �� 5 P� P1\
<br /> E L-SERIES STROBE, 2 WIRE, M-C, RED, CEILING SYSTEM SENSOR SCRL 6 WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYE1809MZ O\GP� �P�'��P�' ��O\GP P�'P� "�PO
<br /> ® E L-SERIES STROBE, 2 WIRE, M-C, RED, CEILING SYSTEM SENSOR SCRL 5 G�P��G�P� \G O�+�\G \GAP`' �P'�o
<br /> 1�I� 5 O O O
<br /> RiE HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR SYSTEM SENSOR P2RK 1 * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND ��'�
<br /> SPECIFICATIONS. THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE OJ
<br /> -AArE GENERIC BOIL 4.7K GENERIC GEOL4.7K 3 USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY
<br /> THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN O� �P O�Z pY-
<br /> N/A BACKUP BATTERY(FACP) POWERSONIC PS-1280F1 2 CRITERIA. O�� JO\0 O�� JO\0 dw 19- O�1
<br /> G P G P G
<br /> c� c� PG PG PG PG PG PG PG PG 0�5 �� �� �F
<br /> DEVICE HEIGHT SCHEDULE SYSTEM INPUTS A B C D E F G H I J K L r�
<br /> DEVICE HEIGHT 1 FIRE ALARM SYSTEM AC POWER FAILURE • • • �i�.J O
<br /> OUTDOOR HORN/STROBE 96" 2 FIRE ALARM SYSTEM LOW BATTERY • • • 00
<br /> HORN/STROBE BO., 3 OPEN CIRCUIT • • • �� 1--d
<br /> 4 GROUND FAULT • • •
<br /> PULL STATION 48" Lj
<br /> Lj
<br /> 5 NOTIFICATION APPLIANCE CIRCUIT SHORT • • • O w
<br /> FIRE ALARM CONTROL PANEL 601• O
<br /> 6 BUILDING MANUAL PULL STATIONS • • • • • •
<br /> POWER SUPPLY 60" 7 CORRIDOR SMOKE DETECTORS • • • • • • Li
<br /> W
<br /> BELL 961, 8 AREA SMOKE DETECTORS • • • • •
<br /> � r,
<br /> Circuit Legend h+NN•K _
<br /> 9 HVAC AIR DUCT SMOKE DETECTORS • • • • FJ-•I ID
<br /> Abbreviation T pe Name Wire Size ANNUNCIATOR 60.. W
<br /> B Signaling line SK — SLG 112AWG 10 AREA HEAT DETECTORS • • • • • • r 0)
<br /> W �
<br /> Notification NOtIfICCJtion 12AWG 11 SPRINKLER TAMPER SWITCH • • • • ^^
<br /> • • • W
<br /> gg gg Fire Alarm Wire List _ 12 SPRINKLER WATER FLOW IN BUILDING • • •
<br /> M
<br /> R1ISERFlRATED'FPLR i6AWG " PLENUM RATED:FPLP 16AWG CONDUIT ONLY:THHN 16AWG • • • • h+-1
<br /> B CONNECTAIR-W161 P-1601 SOUTH WIRE-16REDTHHN 13 FIRE PUMP POWER FAILURE/PHASE REVERSAL
<br /> NOM OD=0.172" NOM OD=0.172" NOM OD=0.096"(2)
<br /> Notification-Notification 14 FIRE PUMP RUNNING • • • • • •
<br /> D RISER RATED:FPLR 12AWG PLENUM RATED:FPLP 12AWG CONDUIT ONLY:THHN 12AWG
<br /> CONNECT AIR-W121 P-1624 CONNECTAIR-W121P-2613 SIMR LL-11588101
<br /> NOM OD=0.244" NOM OD=0.244" NOMOD=0.119"(2) 15 FIRE PUMP SYSTEM NOT IN AUTOMATIC • • • •
<br /> CONDUITSIZE CONDUCTOR AREA CONDUITSIZE CONDUCTOR AREA I REVISIONS:
<br /> 1/2" 0.122 SQ INCH 2" 1.342 SO INCH A B C D E F G H J K L
<br /> 3/4" 0.213 SQ INCH 21/2" 2.343 SO INCH A 2024-05-13
<br /> 1" 0.346 SO INCH 3" 3.538 SO INCH INITIAL REVIEW SET
<br /> 1 1/4" 0.598 SO
<br /> INCH 31/2" 4.618 SQ INCH 2024-�5-17
<br /> 1 1/2" 0.814 SO INCH 4" 5.901 SQ INCH
<br /> PERMIT SET
<br /> 40%FILL 1999 N.E.C. FIELDVERIFY
<br /> 5-22
<br /> FIRE ALARM SYSTEM MATRIX 2O24-o
<br /> KIRBY CORRECTIONS
<br /> SCALE: N.T.S.
<br /> SHEEP WE:
<br /> FIRE ALARM
<br /> DETAILS
<br /> 05-22-24 CHECKED M A K EF0.0 1 1
<br /> x: