My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8413 EVERGREEN WAY BIOMAT 2025-01-06
>
Address Records
>
EVERGREEN WAY
>
8413
>
BIOMAT
>
8413 EVERGREEN WAY BIOMAT 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 9:02:17 AM
Creation date
12/8/2024 7:38:55 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8413
Tenant Name
BIOMAT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2403-007 �r , <br /> 5 � OVAT USA Site Address 8413 Evergreen Way <br /> EVERETT Applicant: Fire Protection Inc <br /> Everett Fire Dept.Permit Review Application Date:03/21/2024 FIRE PROTECTION INC. <br /> 17nw Ash Way,Ste 8 <br /> Status:Approved Description: Install a Wireless Communicator Lynnwood,WA 98037 <br /> Reviewed By:KBrown Review Date: 03/27/2024 425-290-9600 <br /> AM <br /> 03/27/2 9:51:01 FPISEATTLE.COM <br /> A <br /> AES RADO NSTALLAT ON rol <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET INDEX NFPA <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM : AES INSTALLATION ROY L CATS <br /> CENTRAL STATION REPORTING ZONES <br /> QpOTECTj <br /> ZONE # ZONE DESCRIPTION PROJECT DETAILSIn <br /> 1 GENERAL ALARM LL <br /> 2 SUPERVISORY 1. THE EXISTING SINGLE STORY BUILDING IS AND HAS AN EXISTING CONVENTIONAL FIRE ALARM CONTROL ry�JNFPA <br /> TROUBLE yy^ <br /> PANEL (SILENT KNIGHT 5208 FIRE PANEL) LOCATED IN THE SERVER ROOM. CFPS <br /> 3 <br /> 2. A NEW ILL LISTED WIRELESS RADIO COMMUNICATOR (7707-88-ULP) IS BEING INSTALLED, SIGNALS WILL BE #1473 <br /> Oc C. TRANSMITTED BY ZONE TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE <br /> INSTALLED IN THE NEW AES RADIO. <br /> 3. THE NEW AES RADIO WILL USE THE EXISTING FACES DIALER TO SEND CONTACT ID AND ONBOARD RELAYS <br /> O O O O O C. TO TRANSMIT THE FOLLOWING HARDWIRED SIGNALS TO THE CENTRAL SUPERVISING STATION: ZONE 1: FIRE m <br /> VICINITYMAP TI® O O O O O ALARM /WATERFLOW, ZONE 2: SUPERVISORY, AND ZONE 3: TROUBLE. #n <br /> Kscr srATrs uolcArorts <br /> o O O 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. W Z d <br /> 0 <br /> yF w <br /> o coo OO o <br /> NVIt AyUI =N N <br /> IE w w PROJECT CONTACT INFO w a <br /> ® — rc <br /> r!f '1ROi]®E Si1P AIARM ® a �e~i p 3 V = <br /> � O O ¢E <br /> OWNER/TENANT FIRE ALARM CONTRACTOR <br /> © TFJcow Tacow BIOMAT USA FIRE PROTECTION INC Y¢w n¢ <br /> _ ® ® 1ACCOUNTS <br /> TYABLE 17410 ASH Y 8 240 LILYVAE AVE LYNNWOOD, WA 98037 0 <br /> LOS ANGELES, CA 90032 CONTACT DAVID MOW mw� <br /> f <br /> O CONTACT JAD HAMDAN PHONE : 425.290.9600 Wx o PHONE 425.267.9800 DAVID@FPISEATTLE.COM <br /> ZONES 1-8 INPUT J AD.IT A M D A N @G R I F 0 LS.C 0 M o rc H a o <br /> Tx1cc,•exs <br /> BlOmat�USA e a a e a a e a m a,� ,6 s CODE INFO <br /> REVISION RECORD <br /> 526 DATE DESCRIPTION <br /> AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> CASCADE VIE <br /> FIRE CODE INTERNATIONAL FIRE CODE, 2018 EDITION <br /> 99 <br /> BUILDING USE AND OCCUPANCY (B) — FULLY SPRINKLED <br /> STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> Eastmont 1 2Vl 2Ah CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> \ i BATTERY <br /> SILVER LANE V. REMOTE SUPERVISING STATION SECU RITAS INC. <br /> PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> 7i. e PARCEL NUMBERS : 28041300103700 <br /> Stickney 96 EXISTING CONVENHONALEACP(SRENr1WGHr 5208 FIRE PANEL) <br /> AES-7707-88-LILP RADIO COW UNICATOR INSTALLATION NOTES <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> TYPICAL WIRING AND INSTALLATION DETAffS 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 03/18/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safety Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL INSPECTION. <br /> Central Supervising Station m'^ <br /> Control Unit Annunciation ,� 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACE SHALL <br /> c �0 DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> Qi oc TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> E CASINO RD oc '0 to me ®° ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT <br /> m cm S y ova 1 <br /> (NFPA72, SECTION 10.5.5.2). <br /> wZy,�oq°o®t�E QCD 7 CD <br /> c' 2Ao co N <br /> ° J e ° c DEVICE INSTALLATION REQUIREMENTS Q Z 00 <br /> 0 o J ®wL°Qa` � WQ <br /> 10 <br /> 8 � FIRE ALARM DEVICE INSTALLATION REQUIREMENTS � 0 <br /> ��J¢ O�.,43 l NOT PERMITTED O W <br /> 0 <br /> P 0 0`�w 0 O Q y SUPPORT DIFFUSER coERE 4• M ED W <br /> 2 O C O BRACKET W LU <br /> $ D D t�JQ O ip D yZ J-BOX GR W <br /> ID �nt <br /> LU <br /> Q- FACE in ;� ,� ,� e8 qF wF wF`�`� FA DEVICE CEILING 4&, <br /> DETECTOR SMOKE <br /> SERVER RM �P �m�L°c�L°cQ Q AWAIM FROM NOT PERMITTED 4 12" <br /> SYSTEM INPUTS B D F G H I Hvnc DIFFUSERS HERE <br /> Ok7TDOOR 1 Manual Fire Alarm Pull-Station ♦ ♦ ♦♦ 1 H SMOKE <br /> 7ORN <br /> /STROBE 2 Smoke&Heat Detectors ♦ ♦ ♦♦ 2 <br /> 5e� a 3 Wet Waterflow, ♦ ♦ ♦♦♦ 3 SHEET TITLE <br /> ^O[� MAX HEIGHT 92"A.F.F <br /> 4 4 C`. Unused ♦ ♦ ♦♦ MIN HEIGHT 82"AYY V 3 <br /> a 5 Sprinkler Tamper/PIV ♦ ♦ 5 <br /> :5 7N 6 Duct Detectors ♦ ♦ 6 = FIRE ALARM <br /> PROJECT DETAILS <br /> 7 Fire Alarm AC Power Failure ♦ ♦ 7 <br /> 6 Fire Alarm System Low Battery ♦ ♦ $ fifi•A.F.F fio•A.F.F puLL <br /> 9 Open Circuit ♦ ♦ 9 48"A.F.F <br /> N10 Ground Fault ♦ ♦ 10 SHEET NUMBER <br /> A B C D E F G H I <br /> K <br /> Not to Scale FA <br /> O.O <br />
The URL can be used to link to this page
Your browser does not support the video tag.