My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5701 EVERGREEN WAY 2025-01-06
>
Address Records
>
EVERGREEN WAY
>
5701
>
5701 EVERGREEN WAY 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 8:47:38 AM
Creation date
12/8/2024 7:51:00 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5701
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s i <br /> ���I�\\\ //� NW <br /> Permit#: FA2404-016 0 \ 0 \ RODS �/U P � CKUPS Site Address: 5701 Evergreen Way <br /> Applicant: Fire Protection Inc <br /> Application Dale:0110412024 FIRE PROTECTION INC. <br /> Description: Installation of a UL Listed Wireless 17410 Ash Way,Ste 8 <br /> Fire Alarm Communicator Lynnwood,WA 98037 <br /> Review Date: 01/08/2024 425-290-9600 <br /> FPISEATTLE.COM <br /> TOELESS COMMUMCATOR NSTALLATON Everet•L Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET INDEX 04/25/2024 12:44:11 CC]. <br /> PM <br /> 000805173 <br /> SHEET # SHEET DESCRIPTION <br /> CENTRAL STATION REPORTING ZONES <br /> FA 0.0 FIRE ALARM AES INSTALLATION ROY L CATS <br /> AlQpOTECT/O <br /> CONTACT ID TO THE CENTRAL STATIONIn <br /> oQ ?p <br /> PROJECT DETAILS <br /> 111111"' 9 <br /> Y NFPA ^' <br /> b � <br /> dJ y`o <br /> 1. THE EXISTING SINGLE STORY BUILDING IS NOT SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE CFPS <br /> ALARM CONTROL PANEL(SILENT KNIGHT SK-5208) LOCATED IN THE ELECTRICAL ROOM. <br /> � #1473 <br /> 2. A NEW ILL LISTED WIRELESS CELLULAR COMMUNICATOR (TG-7FS) IS BEING INSTALLED AT THE EACH. ALL <br /> SIGNALS WILL BE TRANSMITTED BY ZONES TO THE ILL LISTED SUPERVISING STATION. <br /> O 0 0 O n e <br /> 3. THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES. �e <br /> VICINITYMAP 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. <br /> 0 0 � _a a <br /> W Z a <br /> O <br /> rrnwm Mowmxo O <br /> W=N N <br /> w® PROJECT CONTACT INFO <br /> W y ty M <br /> e Tea r <br /> Grr o 01 aE <br /> OWNER/TENANT FIRE ALARM CONTRACTOR 0 <br /> >ar�Tula lip DREAMERS RODS FIRE PROTECTION INC L)o o q <br /> Marysville 92 ® 5701 EVERGREEN WA 17410 ASH WAY, Ste 8 <br /> BATTERY EVERETT, LL y p 3 <br /> EVERETT, WA 98203 LYNNWOOD, WA 98037 = <br /> ° ° CONTACT JAMEY LECKNER CONTACT DAVID MOW m w G <br /> PHONE 425.348.9190 PHONE : 425.290.9600 3 3 l O i <br /> Lake Stevens JAM EYODREAMERSHOTRODS.COM DAVID@F7PISEATTLE.COM ww+ 0 <br /> bey ILG[7atzn rG-7FS <br /> 17 orcw�a o <br /> Ind REVISION RECORD <br /> Vse—I <br /> CODE INFO DATE DESCRIPTION <br /> Dreamers Rods <br /> 8t C tOrIIS AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> FIRE CODE INTERNATIONAL FIRE CODE, 2018 EDITION <br /> BUILDING USE AND OCCUPANCY : (B) NOT SPRINKLED <br /> STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> EMTNGCONWNHONALFALP(F7RELTTENE-5024FMEPANEL CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> REMOTE SUPERVISING STATION : SECURITAS INC. <br /> PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> 9 PARCEL NUMBERS : 00393200200800 <br /> EdmondsINSTALLATION NOTES <br /> 522 TYPICAL VMNGANDINSTALLATIONDETAIIS <br /> 1_0 <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> A. 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND <br /> THE AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 03/28/2024 <br /> 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> SYSTEM OUTPUTS PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> Reclulred Fire Safety Control INSPECTION. <br /> Central Supervising Station me <br /> 6. THE CELLULAR COMMUNICATOR REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN <br /> Control Unit Annunciation m THE FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING <br /> o1 DEDICATED POWER TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT Z <br /> m` c c SERVES THE FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED <br /> �IOHI.ygY oc A ° ome BREAKER LOCKOUT (NFPA72, SECTION 10.5.5.2). ? Q P�,yoF y w ® 6 Y G <br /> Z <br /> gr,0 DEVICE INSTALLATION REQUIREMENTS a W <br /> 57 y j GiJQ o 06 LU Q <br /> ThSTSf `� FIRE ALARM DEVICE INSTALLATION REQUIREMENTS <br /> of eo° o" aw Jn".� O � H <br /> �` = A y n o •� W <br /> NOT PERMITTED I \ LU <br /> 3� OUTDOOR Q yJ Uo�� m A SUPPORT ACT DIFFUSER HERE a• I LU W <br /> 2 HORN/STROBE ,Q Q ®_ D ro -eox GRID pppBE <br /> &BELL JD`Ja JD`y`yJQ�LG mj /�\ W O W <br /> O C ® t®lJ FA DEVICE CEILING <br /> DETECTO cVCKE Q L0 <br /> emu` aF aF aF R a•• <br /> MINIMUM 3' LU <br /> 4 4 PC PC iNC 4 4 LAWAY FROM NOT PERMITTED 12- <br /> HVAC DIFFUSERS HERE <br /> SYSTEMINPUTS B D F H H SMOKE <br /> 1 Manual Fire Alarm Pull-Station ♦ ♦ 1 <br /> 2 Smoke Detectors ♦ ♦ ♦ 2 <br /> a ♦ ♦ ♦♦ 3 J SHEET TITLE <br /> 3 Heat Detectors MAX HEIGHT 92"A,TF a <br /> FACP `i a Unused 4 MIN HEIGHT 82"AY.F <br /> 0 <br /> a� 5 Unused 5 >- FIRE ALARM <br /> r=/J 6 Unused 6 ®� = PROJECT DETAILS <br /> 7 Fire Alarm AC Power Failure ♦ 7 fifi•A.F.F fi0•A.F.F PUT' <br /> 0 m 8 Fire Alarm System Low Battery ♦ 6 <br /> s"A.F.F <br /> N I- a Open Circuit ♦ ♦ 9 SHEET NUMBER <br /> 10 Ground Fault ♦ ♦ 10 <br /> Not to Scale A B C D E F G H <br /> FA 0.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.