Laserfiche WebLink
REM POWER CABLE (SUPPLIED 6 5 3 4 WITH REM) @ w1 pOpR LEGEND <br /> 00 143- FACP BATTERY CALCULATIONS FACP FIRE ALARM CONTROL PANEL <br /> F 1:11 pKE COMPONENTS QTY. STANDBY ALARM <br /> 5M CURRENT CURRENT <br /> FAC FIRE ALARM COMMUNICATOR (CELLULAR DIALER) <br /> 'I <br /> LVNC'N UDC2000(DAC-100 T) 1 0.01600A 0.02o00A O PHOTOELECTRIC SMOKE <br /> 0 S sLc DEVICES SUPERVISORY ALARM x:xx DETECTOR, BRIGHT WHITE <br /> CURRENT CURRENT <br /> 3�3/4"C - 2#14THHN,1#14G 'Z 0 L1:10 SUBSCRIPT X:XX = DEVICE ADDRESS <br /> PAD300-PD 4 0.00030A 0.00030A 0.00120A 0.00120A <br /> TG P E M nm N�P� PAD300-HD 4 0.00030A 0.00030A 0.00120A 0.00120A H <br /> C Rg. PAD-DUCT 0 0.00030A 0.00030A o.000OOA o.000OOA Q ADDRESSABLE HEAT DETECTOR <br /> FACP EVF-FA-40-402 TG-71 S H x:xx SUBSCRIPT X:XX = DEVICE ADDRESS <br /> 51 L1:09 PAD100-PSSA/PSDA 3 O.o0024A O.o0o24A o.00OBOA O.00OOOA 0 MANUAL PULL STATION <br /> (BY FIRE ALARM VENDOR) °"" 1 4 7 PAD100-RM a 0.00024A 0.00o24A O.o00o0A o.00000A x SUBSCRIPT X:XX = DEVICE ADDRESS <br /> NF-P PAD100-MIM 1 0.00020A 0.00020A 0.00020A 0.00020A <br /> R RR' WALL MOUNT HORN STROBE <br /> H PAD1oo-DIM o 0.00024A 0.00024A o.a000aA a.00000A CD = CANDELA RAYING <br /> EATHER PROOF <br /> Y ALARM <br /> T 3 Li.�UN°N RpOM N�� CT NAc CRT 1(AUX PWR> O.o 8ABr CURRENT <br /> 0.01800A a.110o0A CEILING WMOUNT HORN/STROBE <br /> DC STC2 STC1 TRIP BAIT AC E.O.L. N. NAc CRT 2 O.00A 0.5130A o.000o0A 0.5130A CD = CANDELA RATING <br /> 2 1002 3 4 5 6 2 33 1 2 G 15CD JU 07 RpOM SM°�1_ SLC ALARM LED a.00A o.003600A o.00000A 0.003600A ®07A WALL MOUNT STROBE <br /> CD = CANDELA RATING <br /> Goo °N TOTAL 0.16520A 0.9052A <br /> TOTAL STANDBY CURRENT DRAW= 0.1652 AMPS <br /> rse° Ea��N�oE°1 15CD 06 `�� w2 0R x STANDBY TIME 48 HOURS CONSTRUCTION NOTES <br /> AN <br /> MPN OTAL AL RMM URREN DRAW= 0,90P HOUR TOTAL- 52 AMPS PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> 115CD F L1:05 x ALARM TIME 0.167 HOURS THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> L1:04 ALARM AMP HOUR TOTAL= 0.151 AH SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> (j4"C - (1) PHONE CABLE, RE R°pM STANDBY AH+ALARM AH = 8.08 AH COMPATIBLE WITH AT&T CELL SERVICE. <br /> 1 2 CONDUCTOR FPL OR N°E MONITORED BY TYCO AND <br /> APPROVED EQUAL GpNFE SIGNAL SENT TO CENTRAL x DE-RATING FAED= 1.20(20%) <br /> 5CD S pR TOTAL AH REOUIREO= A AH PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> L1:03 ®E1 0° BOEING FIRE DEPARTMENT MINIMUM BATTERY SCE NEEDED: 10 AH FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> K @ FpGP MPN BATTERY SIZE PROVIDED: 12 AH ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL M NOTE o 1sv EauALs 10 MINUTES of ALARM TIME GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> SCALE: NONE E260 E506 WP 110CD S F L1:02 BUILDING FACP. <br /> L1:01 <br /> pPGjjRgV FACP VOLTAGE DROP CALCULATION POWEPROVR EAND EARTH UGROUND IT TFROMNTHE RBU�LDIINGDFACE <br /> 15CD MIM CELLULAR aRculT SUPPLY ALARM OHMS NGT roTAL AST DEVICE VOLTAIC <br /> POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> 1:012 ANALOG PHON LINE DIALER NAME VOLTAGE CURRENT WRE TYPE 1000 FEET RESISTANCE VOLTAGE DROP% MODULE AND WIRE AS SHOWN. MAINTAIN <br /> PRIMARY TG-7FS-A NAC1(AUX) 20.4 VDC 0.110 A #14AWG SOLID 3.19 10 0.064 20.39 VDC 0.05% <br /> MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> 40-402 FACP NAC2 20.4 VDC 0.513 A #14AWG SOLID 3.19 164 1.064 �19�86 VDC 2.65% BETWEEN POWER AND COMMUNICATION WIRING. <br /> NAC2 N/A 20.4 VDC 0.000 A #14AWG SOLID 3.19 0 0 0 VDC 0% <br /> STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON N/A 20.4 v0c o.000 A #14Awc soup 3.1s o 0 o VDc o% ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. BACKGROUND, THAT READS: <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS ANA 00 PHONE LINE "FIRE ALARM CELLULAR DIALER" <br /> TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. SECONDARY) SEQUENCE OF OPERATIONS <br /> COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR EVF-FA-40-402 *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE,AS SHOWN. PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. OUTPUT FUNCTIONS STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR7 SYSTEM ADDITIONAL CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE 120VAC ANNUNCIATION& SYSTEM IS NOT SUITABLE AT FACP LOCATION. UPDATE DOM <br /> WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. TRANSMISSION ACTIONS WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE BUILDING FIRE ALARM SYSTEM RISER TO BOEING ENGINEER. <br /> FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED <br /> WITHIN 20FT OF EACH OTHER. SCALE: NONE E506 FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM �Z� C7 WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> BUILDING FACE. JO V "FIRE ALARM CELLULAR ANTENNA" <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER Q <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A ��u' V bz INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> SOLE PATH FOR FIRE COMMUNICATIONS. =Q Q Q� 1 = Q SETTINGS AND CELLUAR PHONE NUMBER. PROVIDE <br /> Z = PRINTED LABEL, HANDWRITTEN INFORMATION IS NOT <br /> J� 0 �QQ �� �0 o ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ J Q w Q INFORMATION TO BOEING ENGINEER. <br /> ORDINANCES. S TO go o z <br /> CALE:Lvo EAR COMMUNICATOR INSTALLATION SEQUENCE E26o E5o6 �`Z ��v� V�� �44i 20 <br /> Q <br /> Q. Jm <br /> 40402 BUILDING SYSTEM FACP POINTS <br /> _ 0 <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. btu ��J�tQ���Jm t���Jm t� O O <br /> L1:01 1 SMOKE @ FACP FACP SMOKE DETECTOR - 1E260 S J J J <br /> INPUT CONDITION Q Q BILL OF MATERIALS <br /> L1:02 2 MAN PULL @ E1 DOOR EAST DOOR 1 MANUAL PULL STATION - 1E260 TANDBY CONDITION(NORMAL) ! • ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> U:03 3 CONFERENCE ROOM SMOKE CONFERENCE ROOM SMOKE DETECTOR - 1E260 <br /> U:04 4 S. LUNCH ROOM HEAT SOUTH LUNCH ROOM HEAT DETECTOR - 1E260 C POWER FAILURE i i i i 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> L1:05 5 MAN PULL @ W2 DOOR WEST DOOR 2 MANUAL PULL STATION - 1E260 NY CIRCUIT-OPEN,SHORT,GROUND • • • • 2 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:06 6 S. LUNCH ROOM SMOKE SOUTH LUNCH ROOM SMOKE DETECTOR - 1E260 m LC DEVICE MISSING ! ! ! ! 3 8 3992782 POTTER PAD300 6" BASE <br /> L1:07 7 N. LUNCH ROOM HEAT NORTH LUNCH ROOM HEAT DETECTOR - 1E260 OMM.FAULT/TELGAURD TROUBLE ! ! ! ! 4 4 3992775 POTTER PAD300 PHOTO DETECTOR <br /> L1:08 8 R.R. HEAT RESTROOM HEAT DETECTOR - 1E260 OfBATTERYFAULT-LOW/HIGH VOLTAGE i ! ! ! 5 4 3992776 POTTER PAD300 HEAT DETECTOR <br /> L1:09 9 R.R. HEAT RESTROOM HEAT DETECTOR - 1E260 6 3 3992720 POTTER PAD100 PULL STATION <br /> L1:10 10 N. LUNCH ROOM SMOKE NORTH LUNCH ROOM SMOKE DETECTOR - 1E260 � =IRE ALARM PULL STATION • • • • 7 1 3992700 POTTER PAD100 MICO INPUT MODULE <br /> L1:10 11 MAN PULL @ Wi DOOR WEST DOOR 1 MANUAL PULL STATION - 1E260 MOKEDETECTOR i ! • • 8 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> 1 u:10 12 CELL DIALER FAULT CELL DIALER TROUBLE - 1E260 g 9 1 BK-P2RLED SYSTEM SENSOR HORN/STROBES (WALL MOUNT) <br /> w HEAT DETECTOR i ! ! ! <br /> Lu i i i i 10 2 BK-PC2RLED SYSTEM SENSOR HORN/STROBES CEILING MOUNT <br /> BUILDING FACP POINTS LIST u- 11 2 BK-SRLED SYSTEM SENSOR STROBES (WALL MOUNT) <br /> 12 1 BK-P2RK SYSTEM SENSOR WEATHER PROOF HORN/STROBES <br /> SCALE: NONE E�O6 13 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> 14 1 ISSU00689 SPACEAGE IFIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION By APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE n ACCEPTABILITY J.SHELDON 05 0s 2a FIRE ALARM SYSTEM DETAILS A 05/09/24 <br /> A FIRE ALARM PANEL INSTALLATION 34558629 J.SHELDON K.MULLEN 05 09 24 THIS DESIGN AND/oR CHECKED <br /> / / m SPECIFICATION IS APPROVED K. MULLEN 05 10 24 SHEET <br /> BOE//VG® IN <br /> APPROVED BY DEPT. DATE K. MULLEN DS 10 24 TITLE E506 \ <br /> �T,w Muu.EN CHECKED <br /> APPROVED 34558629 <br /> BUILDING 40-402 NO.JOB COMP NO. <br /> APPROVED MDK EVERETT, WA DWG NO. 40-402-E506 <br />