SPECIFICATIONS: <br /> • I 1 <br /> Maximum Capacity BTU/H 36,400//36,400//36,400 <br /> Rated Capacity BTU/H 35,400//34,900//34,400 <br /> Cooling'(Non-Ducted//Mix//Ducted) Minimum Capacity BTU/H 11,700//11,500//11,300 <br /> Maximum Power Input W 3,960//3,960//3,960 <br /> Rated Power Input W 3,760//3,850//3,940 <br /> Power Factor(208V,230V) % 99.0,99.0//99.0,99.0 H 99.0,99.0 <br /> Maximum Capacity BTU/H 43,000//43,000//43,000 <br /> Rated Capacity BTU/H 36,000//35,200//34,400 <br /> Heating at 47°F'(Non-Ducted//Mix// Minimum Capacity BTU/H 18,300//18,800//19,300 <br /> Ducted) Maximum Power Input W 4,020//4,020//4,020 <br /> Rated Power Input W 3,020//3,060//3,100 <br /> Power Factor(208V,230V) % 98.7,98.7//98.8,98.8 H 98.8,98.8 <br /> Maximum Capacity BTU/H 26,600//26,600//26,600 <br /> Heating at 17°F3(Non-Ducted//Mix// Rated Capacity BTU/H 22,400//22,400 H 22,400 <br /> Ducted) Maximum Power Input W 3,440//3,490//3,540 <br /> Rated Power Input W 2,300//2,470 H 2,640 <br /> Heating at 5°F4(Non-Ducted H Mix// Maximum Capacity BTU/H 24,000 H 24,000 H 24,000 <br /> Ducted) Maximum Power Input W 3,320 H 3,280//3,240 <br /> SEER 19.2//17.6H16.0 <br /> EER' 9.41 H 9.07//8.73 <br /> HSPF(IV) 11.0 1110.4 H 9.8 <br /> Efficiency(Non-Ducted H Mix H Ducted) COP at 47°F2 3.5//3.37 H 3.25 <br /> COP at 17°F at Maximum Capacity' 2.27 H 2.24//2.2 <br /> COP at 5°F at Maximum Capacity4 2.12 H 2.14 H 2.17 <br /> ENERGY STAR®Certified No H No H No <br /> Electrical Power Requirements Voltage,Phase,Frequency 208/230,1,60 <br /> Guaranteed Voltage Range VAC 187-253 <br /> Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 <br /> Voltage:Indoor-Outdoor,S2-S3 V DC 24 <br /> Electrical Short-circuit Current Rating(SCCR) kA 5 <br /> Recommended Fuse/Breaker Size A 25 <br /> Recommended Wire Size AWG 14 <br /> Minimum Circuit Ampacity A 23.1 <br /> Maximum Overcurrent Protection A 25 <br /> Fan Motor Full Load Amperage A 2.43 <br /> Airflow Rate(Cooling/Heating) CFM 2,287/2,382 <br /> Refrigerant Control LEV <br /> Defrost Method Reverse Cycle <br /> Heat Exchanger Type Plate fin coil <br /> Sound Pressure Level,Cooling' dB(A) 54 <br /> Sound Pressure Level,Heating' dB(A) 56 <br /> Compressor Type DC INVERTER-driven Twin Rotary <br /> Compressor Model SNB220FQGMC <br /> Compressor Rated Load Amps A 12 <br /> Outdoor unit Compressor Locked Rotor Amps A 13.7 <br /> Compressor Oil Type//Charge oz. FV50S//23.7 <br /> Base Pan Heater Optional <br /> W:In.[mm] 37-13/32[950] <br /> Unit Dimensions D:In.[mm] 13[330] <br /> H:In.[mm] 31-11/32[796] <br /> W:In.[mm] 40-15/16[1,040] <br /> Package Dimensions D:In.[mm] 17-11/16[450] <br /> H:In.[mm] 40-11/16[1,033] <br /> Unit Weight Lbs.[kg] 139[63] <br /> Package Weight Lbs.[kg] 159[72] <br /> Cooling Intake Air Temp(Maximum/Minimum'") °FDB 115/14 <br /> Outdoor unit operating temperature Cooling Thermal Lock-out/Re-start Temperatures °FDB 10.4/14 <br /> range Heating Intake Air Temp(Maximum/Minimum) °FWB 65/5 <br /> Heating Thermal Lock-out/Re-start Temperatures °FDB 1.4/5 <br /> Charge Lbs,oz 6.0,13.0 <br /> Refrigerant Chargeless Piping Length Ft.[m] 98.0[30.0] <br /> Additional Refrigerant Charge Per Additional Piping Length oz./Ft.[g/m] 0.216[20] <br /> NOTES: <br /> AHRI Rated Conditions 'Cooling(Indoor H Outdoor) °F 80 DB,67 WB H 95 DB,75 WB <br /> (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor H Outdoor) °F 70 DB,60 WB//47 DB,43 WB <br /> 'Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB H 17 DB,15 WB <br /> Conditions 4Heating at 5°F(Indoor H Outdoor) °F 70 DB,60 WB H 5 DB,4 WB <br /> 'Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. <br /> I5°F DB-115°F DB when optional wind baffles are installed <br /> For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. <br /> Although the maximum connectable capacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications <br /> where it is known that all connected units will NOT be operating at the same time. <br /> Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. <br />