My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
801 E CASINO RD BLDG 4 2025-01-03
>
Address Records
>
E CASINO RD
>
801
>
801 E CASINO RD BLDG 4 2025-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 2:31:29 PM
Creation date
12/8/2024 9:35:27 AM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
801
Unit
BLDG 4
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL ABBREVIATIONS HVAC ABBREVIATIONS GENERAL LEGEND HVAC DUCTWORK LEGEND HVAC PIPING LEGEND <br /> ADDN ADDITION, ADDITIONAL MAT MATERIAL AL ACOUSTIC LINED; ALUMINUM OtENiLf[SINGLE LINE DUCTWORK INDICATES VIEW �xx� PIPING IDENTIFIER, SEE ABBREVIATIONS NRS <br /> AFF ABOVE FINISHED FLOOR MAX MAXIMUM AC AIR CONDITIONING N NORTH ARROW DIMENSION LESS THAN 12 INCHES <br /> ALT ALTERNATE MBH THOUSAND BRITISH THERMAL UNITS PER HOUR AD AUTOMATIC DAMPER ELBOW DOWN Seattle//Spokane//Baltimore <br /> APPROX APPROXIMATELY MECH MECHANICAL; MECHANICAL CONTRACTOR AF AIR FOIL Copyright©FSi consulting engineers <br /> ARCH ARCHITECT MED MEDIUM AHU AIR HANDLING UNIT X DETAIL/DRAWING REFERENCE D ELBOW UP <br /> MFG MANUFACTURING X SUPPLY OR EXHAUST TAKEOFF <br /> BAL BALANCING MFR MANUFACTURER BOO BACKDRAFT DAMPER — TEE <br /> BLDG BUILDING MIN MINIMUM; MINUTE BHP BRAKE HORSEPOWER �® SUPPLY DUCT TURNING TOWARD <br /> BSMT BASEMENT MISC MISCELLANEOUS BI BACKWARD INCLINED SECTION REFERENCE TEE DIN <br /> BTU BRITISH THERMAL UNIT MTD MOUNTED BOD BOTTOM OF DUCT — �© SUPPLY DUCT TURNING AWAY T <br /> BTUH BRITISH THERMAL UNITS PER HOUR �--o—� TEE UP <br /> IN NORTH C CONDENSATE; COMMON CONSTRUCTION NOTE �� EXHAUST DUCT TURNING TOWARD 1^ <br /> CAP CAPACITY NA NOT APPLICABLE CFM CUBIC FEET PER MINUTE CAP <br /> CL CENTERLINE NC NORMALLY CLOSED CG CEILING GRILLE Z1 REVISION SYMBOL �© EXHAUST DUCT TURNING AWAY <br /> COND CONDENSATE NIC NOT IN CONTRACT COND CONDENSATE REDUCER <br /> CONN CONNECT; CONNECTION NO NORMALLY OPEN; NUMBER CV CONSTANT VOLUME 0 ROUND DUCT TURNING TOWARD <br /> CONST CONSTRUCTION NOM NOMINAL CWP CONDENSER WATER CIRC. PUMP POINT OF CONNECTION ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS SPECIFIED <br /> CONT CONTINUOUS; CONTINUATION NTS NOT TO SCALE CWR CONDENSER WATER RETURN -0 ROUND DUCT TURNING AWAY <br /> COORD COORDINATE CWS CONDENSER WATER SUPPLY �� BOLD LINE WEIGHT INDICATES NEW WORK ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS SPECIFIED <br /> OC ON CENTER <br /> �--�� E::� TRANSITION _ <br /> DEG DEGREE OD OUTSIDE DIAMETER; OVERALL DIMENSION DOC DIRECT DIGITAL CONTROLS LIGHT LINE WEIGHT INDICATES EXISTING WORK VD VD i\1 CHECK VALVE <br /> DIA DIAMETER OPP OPPOSITE DB DRY BULB TEMPERATURE('F) --F� } � VOLUME DAMPER <br /> DIFF DIFFERENTIAL SLASHED LINE INDICATES EXISTING WORK TO BBD BBD ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS SPECIFIED <br /> DIM DIMENSION PD PRESSURE DROP EA EXHAUST AIR BE DEMOLISHED --IF { BACKDRAFT DAMPER S ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS SPECIFIED z <br /> DISCH DISCHARGE PH PHASE EAT ENTERING AIR TEMPERATURE FD •�� - <br /> DIV DIVISION POC POINT OF CONNECTION EF EXHAUST FAN FIRE DAMPER ui <br /> DIN DOWN PRELIM PRELIMINARY EG EXHAUST GRILLE D� GLOBE VALVE <br /> DP DIFFERENTIAL PRESSURE PRESS PRESSURE EMS ENERGY MANAGEMENT SYSTEM �--�� FLEXIBLE CONNECTION p <br /> dd PRESSURE REDUCING VALVE <br /> DR DRAIN PROP PROPERTY; PROPOSAL EXH EXHAUST LLI <br /> G <br /> DWG DRAWING PS PRESSURE SWITCH N�� I1k TURNING VANES ! , <br /> PSI POUNDS PER SQUARE INCH FA FACE AREA """�""" FLEXIBLE DUCT BOILER MOTORIZED SHUT—OFF VALVE �J <br /> EA EACH PSIG POUNDS PER SQUARE INCH GAGE FC FAN COIL; FORWARD CURVED Q <br /> EFF EFFICIENCY PT PRESSURE/TEMPERATURE TAP FCU FAN COIL UNIT ® SUPPLY DIFFUSER PRESSURE RELIEF VALVE J <br /> ELEC ELECTRICAL ENGINEER FPM FEET PER MINUTE <br /> ENT ENTERING QTY QUANTITY FS FLOW SWITCH Z RETURN GRILLE <br /> EQ EQUAL FV FACE VELOCITY BALANCING VALVE mow z <br /> �// <br /> EQUIP EQUIPMENT REF REFERENCE ® EXHAUST GRILLE 0L O <br /> ET EXPANSION TANK REQD REQUIRED GALV GALVANIZED 1:4 - GAS PRESSURE REGULATOR o�// � <br /> EWT ENTERING WATER TEMPERATURE RET RETURN GR GRILLE Q THERMOSTAT LL <br /> EX, (E) EXISTING RM ROOM U <br /> RPM REVOLUTIONS PER MINUTE HC HEATING COIL AH U) z <br /> F FAHRENHEIT HTG HEATING 1 EQUIPMENT TAG uJ <br /> FIO FURNISHED & INSTALLED BY OWNER S SOUTH HHW HEATING WATER 2018 WASHINGTON STATE ENERGY CODE NOTES O O T_FLEX FLEXIBLE SCHED SCHEDULE HHWR HEATING WATER RETURN ® DIFFERENTIAL PRESSURE SENSOR <br /> FLR FLOOR SECT SECTION HHWS HEATING WATER SUPPLY 1. PROVIDE POST CONSTRUCTION COMMISSIONING AND COMPLETION REQUIREMENTS IN O m Q <br /> FOIC FURNISHED BY OWNER, INSTALLED BY SF SQUARE FEET HX HEAT EXCHANGER ® CARBON MONOXIDE SENSOR ACCORDANCE WITH SECTION C408 AND ACCORDING WITH THE CONTRACT DOCUMENTS. >j <br /> CONTRACTOR SHT SHEET SEE SPECIFICATION SECTIONS 23 05 00, 23 08 00 AND ALL OTHER APPLICABLE = i <br /> FP FIRE PROTECTION; FREEZE PROTECTION SIM SIMILAR IMC INTERNATIONAL MECHANICAL CODE FS FLOW SWITCH SPECIFICATION SECTIONS. U <br /> FT FEET; FOOT; FEET OF WATER(PRESS) SOL SOLENOID 2. PROVIDE CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS <br /> SPEC SPECIFICATION LAT LEAVING AIR TEMPERATURE TS TEMPERATURE SENSOR PERSONNEL FOR ALL MECHANICAL COMPONENTS IN ACCORDANCE WITH SECTION C103.6. U) <br /> GA GAGE; GAUGE SPECD SPECIFIED UPC LOW PRESSURE CONDENSATE SEE SPECIFICATIONS FOR MORE INFORMATION. //I�� LIJ <br /> GAL GALLON SQ SQUARE UPS LOW PRESSURE STEAM THERMOMETER 3. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH SECTION C408.2.2, GENERALLY U V <br /> GC GENERAL CONTRACTOR STD STANDARD 4 ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT J z W <br /> GPM GALLONS PER MINUTE STRUCT STRUCTURAL ENGINEER NPSH NET POSITIVE SUCTION HEAD DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL OTHER APPLICABLE _ <br /> GWB GYPSUM WALLBOARD SPECIFICATION SECTIONS. m W <br /> TBD TO BE DETERMINED OA OUTSIDE AIR 4. ALL PIPING SERVING AS PART OF A HEATING SYSTEM SHALL BE THERMALLY INSULATED IN <br /> H HEIGHT; HIGH TD TEMPERATURE DIFFERENTIAL OAT OUTSIDE AIR TEMPERATURE ACCORDANCE WITH TABLE C403.10.3. SEE SPECIFICATIONS FOR MORE INFORMATION. <br /> HOA HAND OFF AUTOMATIC TEMP TEMPERATURE OSA OUTSIDE AIR 5. PROVIDE CONTROLS IN ACCORDANCE WITH SECTION C403.4 AND IN ACCORDANCE WITH <br /> HOR HORIZONTAL TH TOTAL HEAD OV OUTLET VELOCITY THE CONTRACT DOCUMENTS. Q <br /> HP HORSE POWER THRU THROUGH m 0 HR HOUR TYP TYPICAL PF PREFILTER <br /> HZ HERTZ <br /> UBC UNIFORM BUILDING CODE PHC PREHEAT COIL EXPANSION TANK SCHEDULE UJ J <br /> 0 <br /> IBC INTERNATIONAL BUILDING CODE UL UNDERWRITER'S LABORATORY S SUPPLY CALLOUT BASIS OF DESIGN w O z <br /> ID INSIDE DIAMETER UTIL UTILITY SIP STATIC PRESSURE MAX MAX SYSTEM TANK <br /> IFC INTERNATIONAL FIRE CODE SA SUPPLY AIR; SOUND ATTENUATOR SYSTEM TEMP PRESSURE VOLUME VOLUME U)1: <br /> IMC INTERNATIONAL MECHANICAL CODE V VOLT TYPE MARK LOCATION SERVED TYPE (F) (PSI) (GAL) (GAL) FLUID TYPE MANUFACTURER MODEL <br /> IN INCH VAR VARIABLE T, TSTAT THERMOSTAT U J U U <br /> INFO INFORMATION VEL VELOCITY TEFC TOTALLY ENCLOSED, FAN COOLED ET 401 MECH ROOM BUILDING #4 BLADDER 95 125 1100 13 WATER BELL & GOSSETT B50 W <br /> INSUL INSULATE; INSULATION VERT VERTICAL TG TRANSFER GRILLE <br /> VOL VOLUME <br /> KW KILOWATT UH UNIT HEATER = O <br /> KWH KILOWATT HOUR W WATER; WIDE(DIM); WATT UV UNIT VENTILATOR 00 <br /> W/ WITH EXISTING FLUID COOLER SCHEDULE FOR REFERENCE (TO REMAIN AS-IS) <br /> L LENGTH; LONG (DIM) W WITHOUT VFD VARIABLE FREQUENCY DRIVE LJ J LB POUND WT VAV VARIABLE AIR VOLUME <br /> WEIGHT CALLOUT SYSTEM <br /> LBS/HR POUNDS PER HOUR VENT VENTILATE; VENTILATION TYPE MARK SERVED DESCRIPTION <br /> LF LINEAL FEET YD YARD VD VOLUME DAMPER Q <br /> BAC CLOSED CIRCUIT FLUID COOLER, VFL-363—L, LOW PROFILE, TO COOL 210 GPM <br /> LO LOW YR YEAR <br /> LVG LEAVING WG WALL GRILLE; WATER GAGE OF WATER FROM 97.4 TO 85 F WITH 68 F OUTSIDE WET BULB, PRIMARY FAN MOTOR, <br /> LWT LEAVING WATER TEMPERATURE WSEC WASHINGTON STATE ENERGY CODE FC 401 BUILDING #4 PONY FAN MOTOR, SPRAY PUMP, SUMP HEATER, UNIT SIZE = 15'X4'X12'H. PROVIDE <br /> WB WET BULB TEMPERATURE('F) WITH DISCHARGE HOOD AND DAMPER, MOTOR ENCLOSURE ATTENUATOR, U <br /> BALTIBOND CORROSION PROTECT. SYSTEM, ASME RATED COIL (WITH 1.6 PSI DELTA P), W <br /> ELECTRONIC WATER LEVEL CONTROL. Q <br /> U <br /> PUMP SCHEDULE <br /> ELECTRICAL <br /> CALLOUT PUMP FLUID MOTOR OPNGGATI BASIS OF DESIGN <br /> IMPELLER TOTAL HEAD TYPE TEMP WEIGHT <br /> TYPE MARK LOCATION SERVICE TYPE DIAMETER (IN) RPM FLOW (GPM) (FT) [1] (DEG F) SPEED HP BHP (LBS) V HZ 0 MANUFACTURER MODEL NOTES <br /> W. <br /> CWP 402 MECH ROOM BUILDING #4 CLOSED COUPLED IN—LINE CENTRIFUGAL 9.375 1750 210 85 0% 85 1,800 7.5 6.35 300 460 60 3 BELL AND GOSSETT BG—E80-3X3X9.5C [2][3][4][5] =o�y oFN o <br /> CWP 403 MECH ROOM BUILDING #4 CLOSED COUPLED IN—LINE CENTRIFUGAL 9.375 1750 210 85 0% 85 1,800 7.5 6.35 300 460 60 3 BELL AND GOSSETT BG—E80-3X3X9.5C [2][3][4][5] Z <br /> SCHEDULE NOTES: �� '°'° <br /> [1] FLUID SHALL BE WATER WITH PERCENTAGE PROPYLENE GLYCOL INDICATED Ssioeni¢a�`� <br /> [2] PROVIDE WITH INITIAL IMPELLER AS SCHEDULED. FOLLOWING INSTALLATION AND BALANCING, PROVIDE REPLACEMENT OR TRIMMED IMPELLER FOR ACTUAL CONDITIONS. <br /> [3] PROVIDE WITH VFD, BELL & GOSSETT MODEL TECHNOLOGIC WITH NEMA 1 ENCLOSURE AND BACNET CONNECTION. s� <br /> [4] PROVIDE WITH SUCTION DIFFUSER BELL & GOSSETT MODEL ED-3X <br /> [5] PROVIDE WITH PREMIUM EFFICIENCY MOTORS Project No. <br /> 23032 <br /> Date <br /> BOILER SCHEDULE 09.11.2023 <br /> CALLOUT BOILER GAS BURNER [3] ELECTRICAL BASIS OF DESIGN <br /> NOMINAL MINIMUM EFFICIENCY AT PRESSURE MIN INLET Date Revision <br /> SYSTEM CAPACITY TYPE FLUID TYPE FLOW MIN. FLOW EFFICIENCY DESIGN WATER PD RATING INPUT PRESSURE OPERATING . . . . . . . . . . . <br /> TYPE MARK LOCATION SERVED (BTU/H) [3] [1] [5] (GPM) (GPM) ENT UWT (AHRI) [2] CONDITIONS (FT) (PSIG) FUEL (BTU/H) (IN WG) WEIGHT (LBS) V HZ 0 FLA MANUFACTURER MODEL NOTES <br /> B 402 MECH ROOM BUILDING #4 982,000 FT 0% 98 30 65 85 98.3% 90.8% 4.5 160 NAT. GAS 999,000 4.0 750 120 60 1 12 LOCHINVAR FTXL1000 [4][6][7] <br /> B 403 MECH ROOM BUILDING #4 982,000 FT 0% 98 30 65 85 98.3% 90.8% 4.5 160 NAT. GAS 999,000 4.0 750 120 60 1 12 LOCHINVAR FTXL1000 [4][6][7] Sheet Title <br /> SCHEDULE NOTES: <br /> 1 WT = WATER TUBE; FT = FIRETUBE ABBREVIATIONS, <br /> 2 MINIMUM EFFICIENCY AS SCHEDULED AND AS REQUIRED BY THE WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS. LEGENDS, <br /> 3 NOMINAL BOILER CAPACITY INCLUDED FOR REFERENCE ONLY — DO NOT USE FOR FINAL SIZING OF EQUIPMENT. <br /> 47 PROVIDE WITH CONDENSATE NEUTRALIZATION KIT <br /> 5 FLUID SHALL BE WATER WITH PERCENTAGE PROPYLENE GLYCOL INDICATED NOTES&SCHEDULES <br /> 6 PROVIDE WITH 75 PSI ASME RELIEF VALVE <br /> 7 PROVIDE WITH 2—WAY MOTORIZED ISOLATION VALVE, LOCHINVAR MODEL 100157681 Sheet <br /> PERMIT SET Mo . 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.