MNavieN <br /> THE LEADER IN CONDENSING TECHNOLOGY <br /> NPE-2 Series Tankless Water Heaters <br /> Premium Condensing <br /> Tankless Gas Water Heater Specification Sheet <br /> Item NPE-150S2 NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 <br /> Heat Capacity Natural Gas, 18,000-120,000 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H <br /> (Input) Propane Gas BTU/H <br /> Uniform UEF(for NG&LP) 0.93 0.95 0.96 0.95 0.96 0.95 0.96 <br /> Energy Factor <br /> 35°F(19°C) 6.8 GPM 8.4 GPM(32 Um) 10.1 GPM(38 Um) 11.2 GPM(42 Um) <br /> a Temp Rise (25.8 Um) <br /> Flow Rate 45 T(25°C) 5.3 GPM 6.5 GPM(25 Um) 7.8 GPM(30 Um) 8.7 GPM(33 Um) <br /> (DHW) Temp Rise (20 Um) <br /> 67T(36°Q 3AGPM 4.3GPM 4.4GPM 5.1GPM 5.3GPM 5.6GPM 5.8GPM <br /> Temp Rise (13 Um) (16 Um) (17 Um) (19 Um) (20 Um) (21 Um) (22 Um) <br /> Dimensions 17.3 in(W)x 27A in(H)x 13.2 in(D) <br /> a Weight 62lbs 73lbs 168lbs 77lbs 73lbs 77lbs 73lbs <br /> (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) <br /> Installation Type Indoor or Outdoor Wall-Hung <br /> Overhead View Venting Type Forced Draft Direct Vent <br /> Ignition Electronic Ignition <br /> Ise°u­ 43­.) <br /> Water Pressure 15-150 PSI <br /> Natural Gas Supply Pressure <br /> �IJI (from source) 3.5 in WC-10.5 in WC <br /> m:� eamimmml T Propane Gas Supply Pressure <br /> 8 in WC-13in WC <br /> (from source) <br /> Natural Gas Manifold Pressure -0.04inWC <br /> (min-max) -0.40inWC -003inWC--0.55inWC -0.03 in WC--0.76 in WC -0.03 in WC--0.96 in WC <br /> Propane Gas Manifold Pressure -0.03inWC- _0.02 in WC--0.55 in WC -0.02 in WC--0.76 in WC -0.02inWC--0.96inWC <br /> NPE-180A2/210A2/240A2 (min-max) -0.40in WC <br /> SupplyConnections <br /> SupplyConnections Minimum Flow Rate 0.5 GPM(1.9 Um),<0.01 GPM(0.04 Um)option for"A2"models* <br /> Description diameter e © 40 Cold Water Inlet 3/4 in NPT <br /> A Airintake zin Connection Hot Water 3/4inNPT <br /> Sizes Outlet <br /> B Exhaust Gas Vent tin <br /> Gas Inlet 3/4inNPT <br /> C Hot Water Outlet V.In <br /> Main Supply 120VAC,60Hz <br /> D Gas Inlet '/.In <br /> Maximum <br /> E Recirculationlnlet =/.m " �.m O Power Supply <br /> v, -_ = Power 200 W(max 2 A),350 W(max 4 A)with external pump connected <br /> F Condensate Outlet in <br /> Consumption <br /> G Cold Water Inlet in <br /> Casing Cold Rolled Carbon Steel <br /> 173°I4 ni Materials Heat Primary Heat Exchanger:Stainless Steel <br /> NPE-1509E/18GS2/210S2/240S2 Exchangers Secondary Heat Exchanger:Stainless Steel <br /> Exhaust 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel <br /> SupplyConnections <br /> SupplyConnations 2 in or 3 in Special GasVentType BH(Class II,A/B/C) <br /> Ill Descripion diameter a Venting Intake 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel <br /> 2 in or 3 in Special GasVentType BH(Class II,A/B/C) <br /> A Air Intake tin <br /> �T Vent Clearances 0 in to combustibles <br /> B Exhaust Gas Vent tin <br /> C H°twatero°tlet V/in - outer ® High Elevation 10,100 feet for both NG or LP gas.Please refer to Installation Manual for additional details and instructions. <br /> D Gas Inlet %in <br /> v,in 0 Flame Rod,APS,Ignition Operation Detector,WaterTemperature High Limit Switch,Exhaust Temperature High Limit Sensor,E Condensate Outlet <br /> Power Surge Fuse,Burner High Limit Fuse,Vent Installation Detector(VID) <br /> F Cold Waterinlet V.in - S <br /> -Available for"A2"models configured in an optional ComfortFlow recirculation mode.Energy consumption will increase when the system is <br /> configured for recirculation. <br /> Gas-fired,tankless,condensing,wall-mounted water heater(s)shall be direct vent NPE-2 Series models as manufactured by Navien,Inc.and are certified by CSA International to <br /> the latest edition ofANSI standard Z21.10.3/CSA 4.3.Water heater(s)shall have a 15(5)year limited Heat Exchanger warranty and 5(3)year limited Parts warranty(8(5)year Heat <br /> Exchanger and 5(3)year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is <br /> installed. (qty)NPE water heater(s)shall have a nominal flow rate capacity of GPM/GPH at-'F rise with rated input of BTU/hr.Water heater(s)shall be <br /> vented with 2"Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at a distance not to exceed 75'(or equivalent)with each elbow equal to 8'of pipe length or 3" <br /> Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at a distance of 150'(or equivalent)with each elbow equal to 5'of pipe length.Water heater(s)is rated for <br /> 150 PSI working water pressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WC for natural gas and 8.0"to 13.0"WCfor propane.Unit(s)shall have a steel case,dual <br /> stainless steel heat exchangers,eco premixed burner,negative pressure gas valve,dual venturi,3/4"inlet gas connection,3/4"brass inlet/outlet water connections,water holding capacity of <br /> 0.6 gallon for the NPE-150S2,1.0 gallon for the NPE-180A2 model(0.7gallonsfor NPE-180S2 model),1.2 gallons for the NPE-21OA2/NPE-24OA2 models(0.7 and 0.9 gallons for NPE-21OS2 <br /> and NPE-240S2 models respectively),and a condensate collector.The NPE-180A2 model weighs 73 lbs(NPE-I8OS2 weighs 68lbs),and the NPE-21OA2/NPE-24OA2 models weigh 771bs(NPE- <br /> 210S2 and NPE-240S2 weigh 731bs)and The NPE-150S2 weigh 62lbs.Unit(s)shall include features such as an adjustment for installations at high elevation,temperature lockout,and <br /> temperature options from 97-120°Fin 1°F intervals and 120-140°F in 1°F intervals.The unit(s)shall include additional temperature options of 140-I85°F in 1°Fintervals,for high <br /> temperature commercial applications.All NPE'A2"models shall include an internal circulation pump and 0.5-gallon buffer tank.The water heater(s)shall be controlled by an internal circuit <br /> board that monitors the inlet and outlet temperatures with installed thermistors,sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain <br /> thermal combustion efficiency.Unit(s)shall include safety featuressuch as flame sensor system,high limitsensors,overheat prevention device,freeze protection mode,and fan motor rotation <br /> detector.Multi-system(cascade)applications that require 2 to 32 units shall be installed by connecting the units using cable only connections(Ready Link).The water heater(s)exceeds the <br /> energy efficiency requirements of ASHRAE 90.1-2010 and is listed by SCAQMD rule 1146.2(Type 1)for Low NOx that complies with 14 ng/)or 20 ppm NOx requirements @ 3%02. <br /> *Navien reserves the right to change specifications at any time without prior notice <br /> Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.NavienInc.com 1-NPE2-SS-001-1.1 <br />