My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3625 BROADWAY SONIS KITCHEN 2025-01-03
>
Address Records
>
BROADWAY
>
3625
>
SONIS KITCHEN
>
3625 BROADWAY SONIS KITCHEN 2025-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 2:17:52 PM
Creation date
12/8/2024 9:47:38 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3625
Tenant Name
SONIS KITCHEN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 3-SYSTEM COMPONENTS R-1 o2 Restaurant Fire Suppression Manual R-102 Restaurant Fire Slrppresskxn Manual SECTION 3-SYSTEM COMPONENTS <br /> UL EX3470 ULC EX3470 UL EX3470 ULC EX3470 <br /> PAGE 3.2 REV.11 2014-SEP-01 2014-SEP-01 REV.11 PAGE 3.3 <br /> REMOTE MECHANICAL RELEASE SINGLE TANK ENCLOSURE ASSEMBLY REGULATED ACTUATOR ASSEMBLY OEM RELEASE/BRACKET ASSEMBLY <br /> The Remote Mechanical Release(Pan No.433485)is used The Single Tank Enclosure Assembly(Part No.429870)Is used The Regulated Actuator Assembly(Part No.429850)contains the (FOR OEM IN-CABINET USE ONLY) <br /> to actuate up to five R-102 regulated actuators.The remote in double and multiple-tank systems and must be mounted to regulator,pneumatic actuator,expellant gas hose for agent tank The OEM Regulated Mechanical Release/Bracket Assembly <br /> mechanical release utilizes a 101-10 carbon dioxide cartridge a dgld surface near the regulated release or regulated actuator hookup,and enclosure knockouts to facilitate installing expellant (Part No.79493)contains the same regulated release mecha- <br /> as the actuation pressure to operate the regulated acuuamrs. assembly its expel tent gas line will be connected to. piping,This assembly is used in multiple-lank systems and must ntsm as the standard AUTOMAN Regulated Release Assembly, <br /> The release Is housed in a stainless steel enclosure. The enclosure Is designed for mounting either a 1.5 gallon(Part be mounted to a rigid surface. The OEM Regulated Electrical Release/Bracket Assembly(Part <br /> Also available is an OEM Remote ReleaselBracket Assembly No.429064)or a 3.0 gallon tank(Part No.429862)in a mini- 1'he regulator contains two outlets 13�apart.One outlet is It c ntains')f is Identical to the Mechanical VACsolversion except that <br /> g � It contains a factory installed 120 VAC solenoid and electrical <br /> (Part No,439946).The OEM Remote ReleaselBmckel contains mum amount of space. used to Interconnect the expellant gas hose to the enclosed switch.These releaselbracket assemblies must be Installed In <br /> the same release mechanism as the standard Remote Release, agent tank.The other outlet connects an expellant gas line to a sutable equipment enclosure-either hodzontally or vertically. <br /> and must be installed In a suitable equipment enclosure either ENCLOSURE ASSEMBLY an additional enclosure or bracket assembly.The regulator is <br /> horizontally or vertically.The remote release contains all the .designed to allow a constant flow of expellant gas Into each They contain all the necessary mounting and conduit holes <br /> need <br /> necessary mounting and condut holes needed to fully install �— .agent tank at 110 psi(TO bar). needed to fully n the assembly.The agent tank Is Installed <br /> NOTE:At�Nr TANK MUST separately and n need not be bracketed once it Is piped and filled. <br /> the assembly.Note:OEM Release/Bracket Assembly roust be BE ORDERED 0 The pneumatic actuator Is designed to puncture the expellant Note:OEM ReieaselBracket Assembly must be inslaited high <br /> installed high enough In cabinet so that there is suRclem room SEPARATELY. 6 <br /> [I (SEE PAGE 331 gas cartridge seat upon receiving pressure from the regulated enough in cabinet so that there is sufficient room to in <br /> to install and remove car(ri stall and <br /> S cartridge. a release assembly actuation piping.The enclosure contains a remove cartridge. <br /> 1 knockout to facilitate distribution piping hookup. .'Nona:OLM Regolntcd ElecBkal R431easelarxrkel Assembly 1Pat No.437324)N <br /> 6 -1 Inwnkd to bo osad w11U electric der.U.n. <br /> REGULATED ACTUATOR ASSEMBLY <br /> MOUNTING <br /> m o <br /> RELEASE ENCLOSURE_i NOTE:AGENT TANK <br /> MECHANISM MUST BE !0 b MOUNTING <br /> H ORDERED PNEUMATIC RELEASE BRACKET <br /> SEPARATELY ACTUATOR MECHANISM---�, <br /> (SEE PAGE 3-3) ASSEMBLY 0 <br /> SHIPPING <br /> 13 LR I5.9 1g1 i <br /> REGULATOR <br /> b I REGUtATUR <br /> FIGURE 3.5 <br /> a <br /> SHIPMNC,Wt. <br /> GI ZIPPING WExx17: 9.3 La(4.2 ka1 <br /> 14 4 LB live kill RED PAINTED BRACKET ASSEMBLY <br /> SII La 18 WT. <br /> ' s3u(es killFIGURE 3.4 <br /> The Bracket Assembly(Part No.429878)is used in double and <br /> °0045' multiple-tank systems and must be mounted to a dgid surface <br /> near the regulated release assembly or regulated actuator FIGURE 3-7 . FIGURE 3-9 <br /> orola awes <br /> assembly that Its expellent gas line will be connected to. <br /> The lank bracket is constructed of mild steel and painted red. AGENT TANK ASSEMBLY OEM REGULATED ACTUATOR ASSEMBLY <br /> N is designed for mounting the tank in a minimum amount of The agent tank slipping assembly(3 Gallon(Part No.429862) The OEM Regulated Actuator Assembly (Part No. 418691) <br /> space.The Bracket Assembly can only be utilized with 3.0 gal- and 1.5 Gallon(Part No.429864))consists of a stainless steel Includes the regulator,pneumatic actuator,expellant gas hose <br /> ion tanks(Part No.429862), tank and an adaplorllube assembly.Tire adaptor/tube assem- anti OEM bracket.Also available is an OEM Regulated Actuator <br /> bly contains a burst disc.The burst disc prevents agent leakage Assembly with all IITa above mentioned components except for <br /> BRACKET ASSEMBLY due to significant temperature fluctuations in the area where the bracket.This assembly is Part No.418522. <br /> MGNNnNG the tank Is located,Under normal conditions,the tank requires <br /> RPAcxET hydrostatic testing every twelve years.The date of manufacture <br /> is stamped on the tank nameplate. <br /> a The tank is shipped uncharged and must be tilled with only <br /> ANSULEX Low pH Liquid Fire Suppressant during installation. B <br /> TANK AnnPTaw <br /> ✓ TUBE ASSEMBLY <br /> B <br /> 0 3 GALLON <br /> SlnIPPING WT. <br /> T La o.3 ko <br /> 1.5 GALLON <br /> SHIPPING <br /> WT. <br /> o . 8LB(2.3%0 - ti 11ING Wr.4 LP(1,5 k91 <br />'E AGEN <br /> TANKT ' FIGURE 3,-10 <br /> 5HIPPING WT.a LR P.,k<j) '— 6 <br />•i FIGURES-6 FIGURE 3-6 <br /> ,A,I <br />
The URL can be used to link to this page
Your browser does not support the video tag.