My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
512 94TH ST SW 2025-01-14
>
Address Records
>
94TH ST SW
>
512
>
512 94TH ST SW 2025-01-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2025 8:54:38 AM
Creation date
12/10/2024 11:11:00 AM
Metadata
Fields
Template:
Address Document
Street Name
94TH ST SW
Street Number
512
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION S MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE <br /> RESIDENT BEDROOM DESIGNATIONS OF A B C D E AND F AND CLASSIFICATION CODE S,NSl OR NS2. <br /> R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. <br /> Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R330.9 is provided to evacuate <br /> residents to public area. <br /> Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R330.9 are provided to <br /> evacuate residents to public area. <br /> SLEEPING ROOM A ®Type S Type NS1 10Type NS2 YES NO <br /> Closet door/s are readily openable from the inside IM Yes JE3No N/A I Smoke alarm is installed in the bedroom M 13 <br /> Bedroom door opens easily and quickly from the outside when locked M 13 <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high;at least 20"wide) M 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping roorn window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed 10 13 <br /> SLEEPING ROOM 8 ®Type S Type NSi 13 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside Yes ®No ®N/A Smoke alarm is installed in the bedroom In <br /> Bedroom door opens easily and quickly from the outside when locked M 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) M 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping roorn window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed <br /> SLEEPING ROOM C 10 Type S IMTypeNS1 ®Type NS2 YES NO <br /> Closet door/s are readily openable from the inside Yes ®No ®N/A Smoke alarm Is installed in the bedroomM 13 <br /> Bedroom door opens easily and quickly from the outside when locked M Q <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"hlgh;at least 20"wide) M 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed 0 13 <br /> SLEEPING ROOM D 10 Type S M Type NSl 13 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside jig Yes ®No ®N/A Smoke alarm Is installed in the bedroom M 13 <br /> Bedroom door opens easily and quickly from the outside when locked 1W Q <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed <br /> SLEEPING ROOM E E3 Types JBType NS1 113 Type NS2 YES NO <br /> Closet door/s are readily openable from the insic I Smoke alarm Is installed in the bedroom 12 13 <br /> Bedroom door opens easily and quickly from the outside when locked <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping roorn window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed 0 13 <br /> SLEEPING ROOM F ®Type S 14IType NS1 113Type NS2 YES NO <br /> Closet door/s are readily openable from the insic I Smoke alarm is installed in the bedroom 0 13 <br /> Bedroom door opens easily and quickly from the outside when locked N 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) IN 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping roorn window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.