My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10633 EVERGREEN WAY 2025-01-10
>
Address Records
>
EVERGREEN WAY
>
10633
>
10633 EVERGREEN WAY 2025-01-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2025 9:49:30 AM
Creation date
12/10/2024 2:08:44 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10633
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br /> GENERAL STRUCTURAL NOTES <br /> (The following apply unless shown otherwise on the details.) <br /> CRITERIA <br /> 1. ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,SPECIFICATIONS,THE 2021 EDITION OF THE <br /> INTERNATIONAL BUILDING CODE(IBC). <br /> 2. DESIGN LOADING CRITERIA <br /> EARTHQUAKE: ANALYSIS PROCEDURE:IBC"SEISMIC DEMANDS ON NONSTRUCTURAL COMPONENTS' <br /> SEISMIC DESIGN CATEGORY(SDC)=D <br /> RISK CATEGORY=II <br /> SEISMIC SITE CLASS=D <br /> IMPORTANCE FACTOR le=1.0 <br /> MAPPED MCE Ss=1.393;Si=0.495 <br /> DESIGN ACCELERATION Sds=1.114 <br /> SEISMIC RESISTING SYSTEM:CANTILEVER ELEMENTS,ap=2.5,Rp=2.5 <br /> 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH TECHNICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL <br /> VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. <br /> 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS,MEMBER SIZES,AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS <br /> OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. <br /> 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES <br /> REQUIRED TO PERFORM THEIR WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT <br /> RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE <br /> CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE,NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY <br /> DEFICIENCIES OF THE OWNER,CONTRACTORS,OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. <br /> 6. CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO <br /> FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. <br /> 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF <br /> SIMILAR CHARACTER TO DETAILS SHOWN,SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW AND APPROVAL BY THE <br /> ARCHITECT AND THE STRUCTURAL ENGINEER. WHERE INFORMATION ON THE DRAWINGS IS IN CONFLICT WITH THE SPECIFICATIONS,THE MORE <br /> STRINGENT SHALL APPLY, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. DO NOT SCALE THE <br /> DRAWINGS. <br /> 8. ALL STRUCTURAL SYSTEMS WHICH ARE COMPOSED OF FIELD ERECTED COMPONENTS SHALL BE SUPERVISED BY THE SUPPLIER DURING <br /> MANUFACTURING,DELIVERY,HANDLING,STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. <br /> 9. SPECIAL INSPECTION: EXPANSION BOLTS AND EPDXY GROUTED INSTALLATIONS SHALL BE SUPERVISED IN ACCORDANCE WITH IBC SECTIONS 1704 <br /> &1705 AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER.THE TESTING AGENCY AND INSPECTOR <br /> SHALL BE REGISTERED WITH WABO AND SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND INSPECTION REPORTS DIRECTLY TO THE OWNER, <br /> ARCHITECT,STRUCTURAL ENGINEER,CONTRACTOR AND BUILDING OFFICIAL.ANY MATERIALS WHICH FAIL TO MEET PROJECT SPECIFICATIONS <br /> SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. <br /> CONCRETE <br /> 10. CONCRETE SHALL BE MIXED,PROPORTIONED,CONVEYED AND PLACED IN ACCORDANCE WITH ACI 301. CONSTRUCTION TOLERANCES SHALL NOT <br /> EXCEED THOSE LISTED IN ACI 117. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF fo=2,500 PSI.ALL CONCRETE EXPOSED TO THE WEATHER <br /> AND ALL GARAGE SLABS-ON-GRADE SHALL ATTAIN A 28-DAY STRENGTH fo OF 3,000 PSI IN ACCORDANCE WITH IBC SECTION 1904.1.AND ACI 318 <br /> TABLE 19,3,2.1 THIS INCREASE IN REQUIRED STRENGTH IS FOR DURABILITY ONLY(SPECIAL INSPECTION IS NOT REQUIRED). MIX SHALL CONTAIN <br /> NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5"OR LESS(BEFORE THE <br /> ADDITION OF ADMIXTURES). THE WATER/CEMENT RATIO SHALL NOT EXCEED 0.55 FOR FOOTINGS AND 0.45 FOR ALL SLABS AND EXPOSED <br /> CONCRETE UNLESS OTHERWISE NOTED. <br /> (CONT'D ON GN-2) <br /> RAIRDON VW OF EVERETT 6/6/2024 24196.01 <br /> Iproject date job no <br /> 1511 THIRD AVENUE VEHICLE LIFTS ELH <br /> SUITE 323 drawn by: <br /> SEATTLE,WA96101 <br /> TEL 206957.3900 RAIRDON AUTOMOTIVE GROUP GN-1 <br /> QUANTUM FAX 206.957.3901 <br /> CO sip if 6 t t i.s w.w.gtlamumco.ccm client design by: sheet no. <br />
The URL can be used to link to this page
Your browser does not support the video tag.