Laserfiche WebLink
BeamChek v2017 licensed to:DESIGN LINES Reg#2999-68383 <br /> Buchanan Addition Crawl Space Post <br /> CP-01 Prepared by: RJB Date: 1/03/19 <br /> Selection 6x 6 DF-L Select Solid Wood Column <br /> Conditions NDS 2015, Using values for 5x+solid sawn, Posts and Timbers. <br /> Wet Use <br /> Data Load 3985# Column Area 30.25 in2 Kf 1.00 <br /> Actual Height 2.0 ft le d1 Effective Ht 24 in c 0.80 <br /> Unbraced L1 2.0 ft le d2 Effective Ht 24 in KcE 0.30 <br /> Unbraced L2 2.0 ft Ke Buckling Mode 1.0 FcE 25232 <br /> Fc II (psi) E(psi x mil) <br /> Attributes and Values Controlling d is 5.5 inches <br /> Reference Values 1150 1.6 <br /> le/d psi Area(in2) Adjusted Values 1038 1.6 <br /> Actual 4 132 30.25 CF Size Factor 1.00 <br /> Critical 50 1038 3.84 Cd Duration 1.00 <br /> Status OK OK OK Cm Wet Use 0.91 1.00 <br /> Ratio 8% 13% 13% Cp Stability 0.99 <br /> Note.A wood plate under this column must have an Fc value, perpendicular to the grain,greater than 132 psi. <br /> /'f'' <br />