Laserfiche WebLink
Gravity Load Calculations For: <br /> Myers / Kreger Remodel Addition <br /> 1616 126th St. SE <br /> Everett,Washington <br /> Prepared by Jeff Miller <br /> JM Consulting & Design <br /> 425-821-7518 <br /> October 20, 2017 <br /> Loads: <br /> Roof 25 LL psf <br /> 15 DL psf <br /> Floors 40 LL psf <br /> 10 DL psf <br /> Decks 60 LL psf <br /> 10 DL psf <br /> Walls 10 DL plf for every 1 ft. of vert. ht. <br /> Soil assumed compacted to 1500 psf <br /> Concrete Compressive Strength 2500 psi <br /> Steel Yield Strength 40,000 psi <br /> All beams, joists, rafters and footings are referenced on the drawings <br /> Code Editions: <br /> 2015 IRC or 2015 IBC <br /> 2015 National Design Standards (NDS) <br /> 1 �� <br />