My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Air Handling Unit Test Data <br />Project No. <br />2024-1113 <br />Project I.D. <br />Edward Jones Branch # 98316 <br />77 <br />Test Date <br />9/17/2024 <br />Tested By <br />Vinh Nguyen <br />Area Served <br />FCUs <br />Equipment I.D. <br />(E) ERV-2 <br />Unit Information <br />Manufacturer <br />Daikin Industries, LTD. <br />Model Number <br />VAM1200GVJU <br />Serial Number <br />F002165 <br />Unit Location <br />Hallway <br />Supply Fan Quantity <br />SF Drive Type <br />Direct Drive <br />Return/Relief Fan Quantity <br />RF Drive Type <br />Direct Drive <br />Unit Filter Information <br />Filter I.D. <br />Type <br />I Rating <br />Filter Size / Qty <br />I Filter Size / Qty <br />Filter Size / Qty <br />Pre <br />Pleated <br />I MERV 8 <br />20 x 30 x 2 / 1 (Supply) <br />1 20 x 30 x 2 / 1 (Return) <br />/ - <br />Unit Test Data <br />Total Design Airflow <br />440 CFM <br />Total Actual Airflow <br />470 CFM <br />Design Return Airflow <br />440 CFM <br />Actual Return Airflow <br />435 CFM <br />Min OSA CFM Des / Act <br />440 CFM / 470 CFM <br />Min OSA Position OSA / RA <br />N/A / N/A <br />Design ESP <br />0.56 in.wc <br />Actual ESP <br />0.63 in.wc <br />Act. Volts T1-2/ T2-3/ T1-3 <br />207.0 / / <br />Actual Amps T1 / T2 / T3 <br />4.70 <br />SF Motor Information <br />Manufacturer <br />Daikin VAM1200GVJU <br />Motor Frame / Serv. Factor <br />/ <br />HP / RPM <br />4x3/8 / - <br />Motor Phase / Hz <br />1 / 60 <br />Motor Rated Volts / FLA <br />208-230 / 7.6 <br />Motor Eff. / PF <br />/ <br />IL Return Fan Test Data <br />Total Design Airflow <br />440 CFM <br />Total Actual Airflow <br />435 CFM <br />Design ESP <br />0.56 in.wc <br />Actual ESP <br />0.84 in.wc <br />Act. Volts T1-2/ T2-3/ T1-3 <br />208.0 / / <br />Actual Amps T1 / T2 / T3 <br />4.81 <br />Fan Speed Setting <br />(1) <br />Additional Settings <br />N/A <br />JL RF Motor Information <br />HP / RPM <br />4X3/8 / - <br />Motor Phase / Hz <br />1 / 60 <br />Motor Rated Volts / FLA <br />208-230 / 7.6 <br />Motor Eff. / PF <br />/ <br />111111 General Notes <br />ERV-2, supply and return fan has the same speed mode. Speed mode was set at low speed. The motorized damper at OSA ductwork <br />Note (1) is not working (it was closed). The damper is manually open to balance the ERV airflow. This motorized damper issue needs to be <br />fixed. <br />Page 7 of 49 <br />
The URL can be used to link to this page
Your browser does not support the video tag.