My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OFFICE <br />102C <br />OFFICE <br />102B <br />�� MECHANICAL PLAN <br />�tioRj� „4._11 <br />SHEET NOTES - MECHANICAL: <br />A. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES IN EXISTING <br />CONDITIONS. <br />B. THE SPACE ABOVE THE CEILING IS UTILIZED AS A RETURN AIR PLENUM. ALL MATERIALS WITHIN THE <br />PLENUM SHALL HAVE A FLAME -SPREAD INDEX NOT TO EXCEED 25 AND ASMOKE-DEVELOPED INDEX NOT <br />TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. <br />C. ALL CTWOR HALL BE ONSIDER LOW PR SSURED TWO <br />RK( PERATIN ATABTA PREBS <br />EQUAL TO OR LESS THAN 2INCHES WATER GAUGE) AND SHALL MEET LEAKAGE REQUIREMENTS OF 2021 <br />WSEC, SECTION C403.10.2.1. <br />KEYNOTES <br />1 PROVIDE NEW SUPPLY DIFFUSER, SD-#. REFER TO DIFFUSER CONNECTION DETAIL AND GIRD <br />SCHEDULE FOR MORE INFORMATION. TYPICAL. <br />2 PROVIDE NEW RETURN GRILLE, RG-#. REFER TO DIFFUSER CONNECTION DETAIL AND GRID <br />SCHEDULE FOR MORE INFORMATION. TYPICAL. <br />4 PROVIDE NEW PROGRAMMABLE THERMOSTAT FOR FAN COIL UNIT. CONTRACTOR SHALL COMPLETE <br />ALL REQUIRED CONTROL WIRING. THERMOSTAT SHALL ALLOW FOR AUTOMATIC SETBACK <br />TEMPERATURES AND SHUTDOWN PER THE SETBACK TEMPERATURES INDICATED WITHIN THE <br />MECHANICAL DESIGN CONDITIONS ON DRAWING MO AND IN ACCORDANCE WITH C403.4.2. <br />THERMOSTAT SHALL ALSO ALLOW FOR AUTOMATIC START AND STOP PER C403.4.2.3. START <br />CONTROLS SHALL BE CONFIGURED TO ADJUST THE EQUIPMENT START TIME AS REQUIRED TO <br />BRING EACH AREA TO DESIGN TEMPERATURE JUST PRIOR TO SCHEDULED OCCUPANCY. STOP <br />CONTROLS SHALL BE CONFIGURED TO REDUCE THE HEATING SETPOINT AND INCREASE THE <br />COOLING SETPOINT BY 2 DEGREES F BEFORE SCHEDULED UNOCCUPIED PERIODS. TYPICAL. <br />5 NEW ROUND DUCT TAP CONNECTION. REFER TO DETAIL FOR MORE INFORMATION. TYPICAL. <br />6 PROVIDE NEW FAN COIL UNIT, FCU-#. CONTRACTOR SHALL COMPLETE ALL REFRIGERANT PIPING <br />BETWEEN INDOOR FAN COIL UNIT AND EXISTING MULTIPORT DISTRIBUTION CONTROLLER IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REFER TO FAN COIL UNIT DETAIL AND VRF <br />FAN COIL UNIT SCHEDULE FOR MORE INFORMATION. TYPICAL. <br />7 EXISTING 10-PORT BRANCH CONTROLLER, CARRIER MODEL 48VMD01 OM-3. <br />8 UNDERCUT DOOR BY 1" FOR TRANSFER AIR. TYPICAL. <br />9 BALANCE TO 95 CFM. <br />10 BALANCE TO 155 CFM. <br />11 BALANCE TO 80 CFM. <br />12 BALANCE TO 110 CFM. <br />13 NEW 45 DEGREE TAKE -OFF FITTING. REFER TO BRANCH CONNECTIONS DETAIL FOR MORE <br />INFORMATION. TYPICAL. <br />5 <br />14 PROVIDE MOTORIZED DAMPER AT OA INLET, EA INLET AND RELIEF AIR OUTLET OF EXISTING <br />ENERGY RECOVERY VENTILATOR. DAMPERS SHALL BE A CLASS 1 OPPOSED BLADE DAMPER WITH A <br />MAXIMUM LEAKAGE RATE OF 4 CFM/FT^2 AT 1.0 INCH WATER GAUGE PER AMCA 500D. DAMPERS <br />SHALL BE INTERLOCKED WITH ERV SUCH THAT DAMPERS OPEN WHEN ERV IS ENERGIZED AND <br />CLOSE WHEN ERV IS DE -ENERGIZED. <br />LAWRENCE <br />GROUP <br />St. Louis <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />El <br />cErvT. Be Determined <br />PROITSSIONAL EIR <br />�`clx <br />.IMEG <br />MEG <br />7600 E Orchard Road, Suite 250S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />IMEG Project No: 24000280.07 <br />1' <br />q �o <br />Y�S7ONALpENO` <br />of. at.a�ay <br />hp?o7- t0•ldib <br />LU <br />m blir N.pare aawitlg�orm6 r <br />— d—gerd Mteibon itare tM1eede P.Pe dNe <br />No. Deacriptbn Data <br />1 Revision 1 Date 1 <br />2 FOR CONSTRUCTION 07/11/12024 <br />3 1 MECH PERMIT 07124/2024 <br />4 1 RETURN DUCTING OS/08/2024 <br />5 MECH REVIEW OS/21/2024 <br />MECHANICAL PLAN <br />Pq.dxa a— w <br />2024906.011 <br />Drewn By ■ ■ <br />MSK ww A <br />MARCH 27. 2024 IYIL <br />Page 24 of 49 <br />
The URL can be used to link to this page
Your browser does not support the video tag.