My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
We invented the concept of flexible fire protection" <br />NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS 2016 EDITION <br />9.2.1.3.3 Flexible° Sprinkler Hose Fittings. <br />9.2.1.3.3.1 Listed flexible sprinkler hose fittings and their anchoring components intended for use in installations <br />connecting the sprinkler system piping to sprinklers shall be installed in accordance with the requirements <br />of the listing, including any installation instructions. <br />9.2.1.3.3.2 When installed and supported by suspended ceilings, the ceiling shall meet ASTM C 635, Standard <br />Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for <br />Acoustical Tile and Lay -In Panel Ceilings, and shall be installed in accordance with ASTM C 636, <br />Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and <br />Lay -In Panels. <br />9.2.1.3.3.3 When flexible sprinkler hose fittings exceed 6 ft (1.83 m) in length and are supported by a suspended <br />ceiling in accordance with 9.2.1.3.3.2, a hanger(s) attached to the structure shall be required to ensure <br />that the maximum unsupported length does not exceed 6 ft. (1.83 m). <br />9.2.1.3.3.4 Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, <br />a label limiting relocation of the sprinkler shall be provided on the anchoring component. <br />A. 9.2.1.3.3.3 The committee evaluation of flexible sprinkler hose fittings supported by suspended ceilings was based <br />on a comparison of the weight of a 6 ft, 1 in (1.8 m) diameter Schedule 40 water -filled unsupported <br />armover weighing approximately 13 lb (5.9 kg) to the weight of a 6 ft, 1 in. (1.8 m) diameter water -filled <br />flexible hose fitting weighing approximately 9 lb (4.1 kg). The information provided to the committee <br />showed that the maximum load shed to the suspended ceiling by the flexible hose fitting was <br />approximately 6 lb (2.7 kg) and that a suspended ceiling meeting ASTM C 635, Standard Specification <br />for the Manufacture, Performance, and Testing of Metal Suspension Systems of Acoustical Tile and <br />Lay -In Panel Ceilings, and installed in accordance with ASTM C 636, Standard Practice for <br />Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay -In Panels, can <br />substantially support that load. In addition, the supporting material showed that the flexible hose <br />connection can be attached to the suspended ceilings because it allow the necessary deflections under <br />seismic conditions. <br />A.9.2.1.3.3.4 An example of language for the label is as follows: <br />CAUTION: DO NOT REMOVE THIS LABEL. <br />Relocation of this device should only be performed by qualified and/or licensed individuals that are aware <br />of the original system design criteria, hydraulic criteria, sprinkler head listing parameters, and knowledge <br />of the state and local codes including NFPA 13 installation standards. Relocation of the device without <br />this knowledge could adversely affect the performance of this fire protection and life safety system. <br />Reproduced with permission from NFPA 13-2016, Standard for the Installation of Sprinkler Systems, Copyright© <br />2015, National Fire Protection Association. This reprinted material is not the complete and official position of the <br />NFPA on the referenced subject, which is represented only by the standard in its entirety. <br />FLEXHEAD <br />• I N D u S TRI ES-L.) www.flexhead.com <br />.M �.Llaikore <br />
The URL can be used to link to this page
Your browser does not support the video tag.