RG-1 <br />0 <br />OFFICE <br />102D <br />SD-, <br />6/55 <br />SD-1 <br />121360 <br />®111 <br />Ox16 <br />FCU-11 <br />BREAK ILJ`I//j <br />107 <br />SD-1 <br />12/280 <br />SD-1 <br />8/155 <br />�n <br />RG-1 <br />OFFICE <br />102C <br />RG-1 <br />ink <br />S <br />} <br />v <br />6/55 <br />1 <br />3 <br />(E) ERV-2 <br />RG 1 <br />OFFICE <br />102E <br />L <br />SD-1 <br />8/115 <br />SD-1 <br />6155 <br />° <br />m <br />1 <br />SDA SDA <br />14/420 141420 <br />20x16 SD-1 <br />8/180 <br />,111l�l � III <br />RG-1 SD-1 RG-1 <br />SMALL CONFERENCE 8/140 SMALL CONFERENCE <br />106D 106C <br />RG-1 <br />LARGECONFERENCE SD-1 SD-1 <br />106E 1 8/180 10/250 <br />BRANCH SUPPORT w <br />,a,e <br />© RG-1 <br />FCU-4 <br />5 <br />32x8 10x12 <br />EQIP/SUPPLY <br />104 <br />32x8 <br />8112 SD-1 <br />/120 __15U 16/70 <br />OFFICE SD_1 SD-1 <br />102E 6155 6/55 RG-1 <br />LOUNGE / <br />9111 109 <br />OFFICE -- <br />102A <br />SD-1` — <br />6/55 ZZ <br />PASSAGE <br />03 <br />F1 U� <br />II <br />FA DUCT UP <br />THROUGH RC,_1 <br />ROOF <br />CA DUCT UP <br />THROUGH <br />ROOF MEDIUM CONFERENCE <br />106A <br />SD-1 <br />12/350 <br />RG-1 <br />u(---L) <br />I I �7ji/ <br />OFFICE SD 1 <br />1 <br />SD-1 <br />6/85 <br />102E 6/55 <br />STORAGE <br />108 <br />BRANCH SUPPORT <br />SD-1 <br />6/50 <br />101A <br />�\ MECHANICAL PLAN <br />,VQ R, <br />SD-1 O <br />6/90/90 <br />RG-1 <br />32x8 <br />FCU-3 WELCOME <br />100 <br />N RG-1 <br />SO/240 I 1110/240 I 11. <br />SHEET NOTES - MECHANICAL: <br />A. CONTRACTOR SHALL NOTIFY ENGINEER OFANY DISCREPANCIES IN EXISTING <br />CONDITIONS. <br />B. THE SPACE ABOVE THE CEILING IS UTILIZED AS A RETURN AIR PLENUM. ALL MATERIALS WITHIN THE <br />PLENUM SHALL HAVE A FLAME -SPREAD INDEX NOT TO EXCEED 25 AND A SMOKE -DEVELOPED INDEX NOT <br />TO EXCEED 50, WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. <br />C. ALL DUCTWORK SHALL BE CONSIDERED LOW PRESSURE DUCTWORK AND SHALL MEET LEAKAGE <br />REQUIREMENTS OF 2018 WSEC, SECTION C402.5. <br />KEYNOTES <br />1 PROVIDE NEW SUPPLY DIFFUSER, SD-#. REFER TO DIFFUSER CONNECTION DETAIL AND GIRD <br />SCHEDULE FOR MORE INFORMATION. TYPICAL. <br />2 PROVIDE NEW RETURN GRILLE, RG-#. REFER TO GIRD SCHEDULE FOR MORE INFORMATION. <br />TYPICAL. <br />3 PROVIDE NEW VENTILATION DUCTWORK FROM EXISTING ENERGY RECOVERY VENTILATOR. <br />4 PROVIDE NEW PROGRAMMABLE THERMOSTAT FOR FAN COIL UNIT. CONTRACTOR SHALL COMPLETE <br />ALL REQUIRED CONTROL WIRING. TYPICAL. <br />5 NEW ROUND DUCT TAP CONNECTION. REFER TO DETAIL FOR MORE INFORMATION. TYPICAL. <br />6 PROVIDE NEW FAN COIL UNIT, FCU-#. CONTRACTOR SHALL COMPLETE ALL REFRIGERANT PIPING <br />BETWEEN INDOOR FAN COIL UNIT AND EXISTING MULTIPORT DISTRIBUTION CONTROLLER IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REFER TO FAN COIL UNIT DETAIL AND VRF <br />FAN COIL UNIT SCHEDULE FOR MORE INFORMATION. TYPICAL. <br />7 PROVIDE NEW RETURN DUCTWORK AT INLET OF FAN COIL UNIT. COVER OPEN END OF RETURN <br />DUCT WITH 112" WIRE MESH. TYPICAL. <br />8 EXISTING 10-PORT BRANCH CONTROLLER, CARRIER MODEL 48VMD01 OM-3. <br />LAWRENCE <br />GROUP <br />St. Louis <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />Pmje .. <br />GENERAL CONTRACTOR: <br />To Be Determined <br />PROFESSIONAL ENGINEER: <br /><>IMEG <br />IMEG <br />7600 E Orchard Road, Suite 250-S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />IMEG Project No: 24000280.07 <br />E <br />ow p <br />6'hf �taT 1l <br />•t�G <br />7oNnt F-� <br />Af 97, 10. 2 od 6 <br />TOE <br />/`) <br />(^V' <br />W <br />O <br />O-) <br />i <br />W <br />Q <br />N <br />ILL <br />Q <br />U <br />Q <br />0 <br />�2 �O <br />LL1The <br />C N <br />m W <br />(2) <br />Professional ArchitecCs seal affbced ro this sneer <br />applies only to the material and items she on this <br />sheet All drewings, inatrumentsorothardocumenta rot <br />.Aibilirg this seal shall not be considered prepared by <br />this arohiteat and this architect is pnewly disclaims any <br />and all resporeibility for such plans, drawing, or <br />dowments not exhibiting this seal. <br />This drawing and detail, on it are the wle property of the <br />architect and may be uwd for this specific project only. <br />it,hall not be maned, copied or reproduced, in whole or <br />part, or fher or any otpurpose or project with- the <br />written consent of the erchXect. <br />No. Description Date <br />1 Revision 1 Dale 1 <br />2 <br />FOR CONSTRUCTION <br />07/11/2024 <br />3 <br />1 MECH PERMIT <br />07/24/2024 <br />Sheet - <br />MECHANICAL PLAN <br />Prged Number Sheet Number. <br />2024906.011 <br />D.- Sy <br />MSK A <br />I... Dace: L <br />MARCH 27, 2024 <br />