Laserfiche WebLink
13®SimplEX Multi-Application Peripherals <br /> UL, ULC, CSFMListed; FM Approved; IDNet and MAPNET II Communicating Devices, <br /> MEA (NYC) Acceptance* Individual Addressable Modules (IAMs) <br /> IDNet or MAPNET II addressable communications ��� �_ <br /> supply both data and power over a single wire pair USAInIplDex <br /> to provide**: 4090 90010 / <br /> SUP1nSED,AN <br /> • Supervised Class B monitoring of normally open,dry W.I R.51i 331 <br /> contacts DATE M 2. a. 4 <br /> DE <br /> • Total wiring distance from IAM to supervision a / <br /> resistor(s)of up to 500 ft(152 m) ® 9 000ppppn <br /> • Monitored connection is compatible with Simplex <br /> 2081-9044 Overvoltage Protectors for outdoor wiring or <br /> electrically noisy applications 4090-9001 Supervised AM <br /> • For use in indoor locations up to 158'F(70'C)such as (shown approximately 3/4 size) <br /> attic spaces or similar applications <br /> For use with following Simplex control panels: <br /> • Model Series 4007ES,4008,4010,4010ES,and 4100ES <br /> fire alarm control panels for IDNet communications <br /> • Model Series 4100/4100U/4100ES,4120,4020,and <br /> 2120 Communicating Device Transponders(CDTs) <br /> equipped with MAPNET II communications <br /> Model 4090-9001: <br /> • Enclosed design minimizes dust infiltration <br /> • Mounts in standard single gang electrical box u� LISTED <br /> IS�ENOG DEVICE <br /> • Screw terminals for wiring connections <br /> • Visible LED flashes to indicate communications <br /> • Optional covers are available to allow LED to be 4090-9051 Supervised AM <br /> viewed after installation(requires mounting bracket, (shown approximately 3/4 size) <br /> ordered separately) <br /> Model 4090-9051: <br /> • Encapsulated design for extended exposure to high _ • <br /> humidity(LED is not present on this model) <br /> • Color coded 18 AWG leads for wiring Individual addressable modules (IAMs)receive <br /> IDNet communications provides current limited both power and communications from a two-wire <br /> monitoring: MAPNET II or IDNet circuit.They provide location <br /> • Provides monitoring of tamper switch(supervisory) specific addressability to a single initiating device(such <br /> and waterflow switch(alarm)on same circuit using as single station smoke detector alarm contacts or heat <br /> one point detector contacts)or multiple devices at the same location <br /> by monitoring normally open dry contacts and the wiring <br /> • Available with IDNet communications only to an end-of-line resistor. <br /> Multiple operation modes are available and are Model 4090-9001 is packaged in a thermoplastic <br /> selectable at the control panel: housing and provides screw terminal connections and a <br /> • Contact closure status can be tracked status indicating LED. <br /> • Momentary contact closure conditions can be selected at <br /> the panel to be latched or tracked(not available with the Model 4090-9051 is an encapsulated package with wire <br /> 2120 CDT) leads.It does not provide a status indicating LED. <br /> UL listed to Standard 864 <br /> * These products have been approved by the California State Fire Nhishal(CSF4 pursuant <br /> to Section 13144.1 ofthe California Health and Safety Code.See CSFMListing <br /> 7300-0026:223 for allowable values and/or conditions concerning material presented in this <br /> document.Accepted for use—City ofNewYork Department of aildnigs—NEA35-93E. <br /> Additional listings may be applicable;contact your local Simplex product supplier for the <br /> latest status.listings and approvals under Simplex Tare Recorder Co.are the property of <br /> Tyco Fire Protection Products. <br /> S4090-0001-11 11/2014 <br />