0,,Simp1Ex TrueAlarm Analog Sensing <br /> UL, ULC, CSFM Listed; FM Approved, TrueAlarm Analog Sensors — Photoelectric <br /> MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories <br /> TrueAlarm analog sensing provides: <br /> • Digital transmission of analog sensor values via IDNet or <br /> MAPNET II two-wire communications <br /> For use with the following Simplex®products: <br /> • 4007ES,4010,4010ES,4100ES,and 4100U Series control <br /> panels;and 4008 Series control panels with reduced feature <br /> set(refer to data sheet S4008-0001 for details) <br /> • 4020,4100,and 4120 Series control panels,Universal <br /> Transponders,and 2120 TrueAlarm CDTs equipped for 4098-9714 TrueAlarm Photoelectric <br /> MAPNET II operation Sensor Mounted in Base <br /> Fire alarm control panel provides: <br /> • Peak value logging allowing accurate analysis of each - • • <br /> sensor for individual sensitivity selection <br /> • Sensitivity monitoring satisfying NFPA 72 sensitivity Digital Communication of Analog Sensing.TrueAlarm <br /> testing requirements;automatic individual sensor calibration analog sensors provide an analog measurement digitally <br /> check verifies sensor integrity communicated to the host control panel using Simplex <br /> addressable communications.At the control panel,the data is <br /> • Automatic environmental compensation,multi-stage alarm analyzed and an average value is determined and stored.An <br /> operation,and display of sensitivity directly in percent per alarm or other abnormal condition is determined by comparing <br /> foot the sensor's present value against its average value and time. <br /> • Ability to display and print detailed sensor information in <br /> plain English language Intelligent Data Evaluation.Monitoring each sensor's <br /> average value provides a continuously shifting reference point. <br /> Photoelectric smoke sensors provide: This software filtering process compensates for environmental <br /> • Seven levels of sensitivity from 0.2%to 3.7% factors(dust,dirt,etc.)and component aging,providing an <br /> (refer to additional information on page 3) accurate reference for evaluating new activity.With this <br /> Heat sensors provide: filtering,there is a significant reduction in the probability of <br /> • Three fixed temperature sensing thresholds: 135'F, 155'F false or nuisance alarms caused by shifts in sensitivity,either up <br /> and 190'F or down. <br /> • Rate-of-rise temperature sensing Control Panel Selection.Peak activity per sensor is stored to <br /> • Utility temperature sensing assist in evaluating specific locations.The alarm set point for <br /> each TrueAlarm sensor is determined at the host control panel, <br /> • Listed to UL 521 and ULC-5530 selectable as more or less sensitive as the individual application <br /> General features: requires. <br /> • Operation is for ceiling or wall mounting Timed/Multi-Stage Selection.Sensor alarm set points can be <br /> • Listed to UL 268 and ULC-S529 programmed for timed automatic sensitivity selection(such as <br /> • Louvered smoke sensor design enhances smoke capture by more sensitive at night,less sensitive during day).Control panel <br /> directing flow to chamber;entrance areas are minimally programming can also provide multi-stage operation per sensor. <br /> visible when ceiling mounted For example,a 0.2%level may cause a warning to prompt <br /> • Designed for EMI compatibility investigation while a 2.5%level may initiate an alarm. <br /> • Magnetic test feature is provided Sensor Alarm and Trouble LED Indication.Each sensor <br /> • Different bases are available to support a supervised or base's LED pulses to indicate communications with the panel.If <br /> unsupervised output relay,and/or a remote LED alarm the control panel determines a sensor is in alarm,or is dirty or <br /> has some other type of trouble,the details are annunciated at the <br /> indicator control panel and that sensor base's LED will be turned on <br /> Additional base reference: steadily.During a system alarm,the control panel will control <br /> • For isolator bases,refer to data sheet 54098-0025 the LEDs such that an LED indicating a trouble will return to <br /> • For sounder bases,refer to data sheet S4098-0028 pulsing to help identify the alarmed sensors. <br /> • For photo/heat sensors,refer to data sheet S4098-0024 <br /> (single address)and S4098-0033(dual address) <br /> These products have been approved by the California State Fire Marshal(CSFM)pursuant to <br /> Section 13144.1 of the California Health and Safety Code.See CSFM Listings <br /> 7272-0026:218,7271-0026:231,7270-0026:216,and 7300-0026:217 for allowable values <br /> and/or conditions conceming material presented in this document.Accepted for use—City of <br /> New York Department of Buildings—MEA35-93E.Additional listings may be applicable, <br /> contact your local Simplex product supplier for the latest status.Listings and approvals under <br /> Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. <br /> S4098-0019-23 8/2017 <br />