My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8717 7TH AVE SE 2024-12-31
>
Address Records
>
7TH AVE SE
>
8717
>
8717 7TH AVE SE 2024-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 1:17:49 PM
Creation date
12/17/2024 10:40:30 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8717
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett Permit Review <br /> EVERETT Status: Reviewed for Permit COASTAL MECHANICAL <br /> WASHINGTON <br /> SOLUTIONS <br /> GENERAL NOTES DUCTWORK SYMBOLS PIPING SYMBOLS GENERAL SYMBOLS Mechanical Reviewer <br /> Jason Morrissey 0510212024 2.51 :19 PM 11018 VERNON RD <br /> INSTALL SEISMIC BRACING FOR ALL DUCTWORK,EQUIPMENT AND PIPING PER ® ® DUCT SECTION-SUPPLY •�I BALL VALVE ITEM TO BE DEMOLISHED LAKE STEVENS,VIA 98258 <br /> BALANCING VALVE <br /> I.B.C.REQUIREMENTS. Phone:425-210-7522 <br /> rSCh <br /> INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. El 0 DUCT SECTION-RETURN GATE VALVE EQUIPMENT IDENTIFICATION CMS.WA.ENGINEERINGOGMAIL.COM <br /> EF-1 <br /> MECHANICAL DRAWINGS ARE DIAGRAMATIC IN NATURE,AND DO NOT 20x12 RECTANGULAR DUCT(INSIDE DIMENSION) ty CHECK VALVE <br /> NECESSARILY REFLECT EVERY REQUIRED OFF-SET,FITTING OR ACCESSORY. <br /> _ 1 CONTROL VALVE -2 WAY <br /> OF COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING DEMO ITEM ER FACE SI E <br /> 20"a ROUND DUCT CEILING DIFFUSER MARK SUBJECT TO FIELD <br /> \� J. �B <br /> STRUCTURE AND ALL OTHER TRADES. 0p�9T VIASWrN <br /> THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO ( FLEX CONNECTION ��� UNION FUS Z <br /> ��TYPE(CD NEC SIZE DIFFUSER) o <br /> INSPECTION <br /> LING <br /> BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS.VERIFY --------- -/I BUTTERFLY VALVE 24-10 CD��DESIGN CFM ~ <br /> EXACT SIZE,LOCATION AND CONDITION OF ALL EXISTING SYSTEMS,DUCTS ___ 20x12 ___ LINED DUCT(INSIDE DIMENSION) 300 CFM <br /> CONTROL VALVE-3 WAY u�e ce 2A°' <br /> PIPES,UTILITIES AND BUILDING STRUCTURE. T <br /> IL <br /> 12x10 FLEX CONNECTION fs'ryONALEaG\ <br /> VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. -____ LINED DUCT(INSIDE DIMENSION) <br /> REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS OF I, �` ( 90'CONICAL SPIN-IN FITTING GAS COCK GRILLE MARK 4/15/2024 <br /> CR1 GATE VALVE 3 WAY GRILLE LENGTH <br /> MECHANICAL EQUIPMENT(VOLTAGES,ETC.) GRILLE WIDTH <br /> FLEXIBLE DUCT C�0 GLOBE VALVE <br /> ILLE <br /> D6 PRESSURE REDUCING VALVE 24x12 RG��TYPE EG=EXHAUST GRILLE <br /> ��� TURNING VANE ,q M <br /> MECHANICAL NOTES 300 CF <br /> 7 r PRESSURE RELEIF VALVE SG=SUPPLY GRILLE <br /> TG=TRANSFER GRILLE <br /> 1.THE FOLLOWING NOTES APPLY TO ALL MECHANICAL,PLUMBING AND FIRE PROTECTION DRAWINGS. CEILING DIFFUSER DESIGN CFM <br /> ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL,PLUMBING MID FIRE THERMOMETER <br /> PROTECTION DRAWING. © RETURN/EXHAUST/TRANSFER GRILLE OR REGISTER T5 TEMPERATURE SENSOR REGISTER MARK <br /> 2.MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS.REFER TO REGISTER LENGTH <br /> ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS. I VOLUME DAMPER PIPE DOWN /f GRILLE WIDTH <br /> 3.ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS,REQUIRED BY � MOTORIZED DAMPER �0 PIPE UP ��IYPE SR=SUPPLY REGISTER <br /> CODES OR RECOMMENDED BY MANUFACTURER ARE PROVIDED. 24x12 RG RR=RETURN REGISTER <br /> � <br /> 4.REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FIT QII HOSE DRAIN VALVE 300 CFM-DESIGN CFM <br /> fINCS,VALVES.ETC.FLOOR PLANS � BACKDRAFT DAMPER <br /> AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY.PROVIDE 0 VENT THROUGH ROOF H 0 <br /> PI THERMOSTAT PING SHOP DRAWINGS COORDINATED WITH OTHER TRADES.REFER TO SPEC.FOR ADDITTIONAL O VENT rTl <br /> SHOP DRAWING REQUIREMENTS. ------------ <br /> OS SENSOR - COLD WATER(DOMESTIC) DETAIL REFERENCE 1 <br /> HOT WATER(DOMESTIC O W <br /> ABBREVIATIONS © CO2 SENSOR ) 1 DETAIL NUMBER Z 00 <br /> W O1 <br /> --- HOT WATER RECIRC.(DOMESTIC) M2.3 (5QI <br /> DRAWING ON WHICH <br /> CONT. CONTINUATION HWS HEATING WATER SUPPLY SECTION IS LOCATED <br /> DWG DRAWING -----HWR----- HEATING WATER RETURN ✓' y✓� <br /> (E) EXISTING ITEMS CHS CHILLED WATER SUPPLY SECTION REFERENCE <br /> EER ENERGY EFFICIENCY RATING -----CHR----- CHILLED WATER RETURN <br /> EFF EFFICIENCY/ EFFICIENT G NATURAL GAS a SECTION NUMBER i-� <br /> ) �:: P4 z <br /> W <br /> ELECT. ELECTRICAL D CONDENSATE DRAIN M2.3 <br /> DRAWING ON WHICH <br /> EWT ENTERING WATER TEMPERATURE REDUCER SECTION IS LOCATED <br /> FCO FLOOR CLEANOUT 00 rT, <br /> LWT LEAVING WATER TEMPERATURE Ql REVISION IDENTIFICATION 1.4 w <br /> POC POINT OF CONNECTION W <br /> TYP TYPICAL <br /> 00 FLAG NOTE <br /> LEGAL DESCRIPTION <br /> SEC 18 TWP 28 RGE 05RT-5A)BEG NI/4 CDR TH N88.55 18W 1173.47FT TH <br /> WASHINGTON STATE ENERGY CODE NOTES ALG CA RD S 413.06FT TH E 20FT TPB TH E 561.67FT TH S 904.37 FT TO N VENTILATION CALCULATIONS <br /> MGN OF RD TH N88.50 56W 559.78FTTH ALG ELY MGN OF RD N 893.08FT TO <br /> TPBLESS FDT BEG NI/4 CDR SAID SEC TH W ALG N LN SAID SEC 1173.47FT TO <br /> CA CO RD TH S ALG SAID CA 413.06FT TH E 20FT TO TPOB TH E 150FT TH ROOM AREA, SF OCCUPANTS,PEOPLE CFM/SO FT PEOPLE CFM (AREA) CFM (OCC) REQUIRED RED PROVIDED <br /> 1. WHERE USED TO CONTROL BOTH HEATING AND COOLING,ZONE S 368FT TH E 40FTTH S TAP 120FT N OF N LN CO RD TH E 369.78FT TH S <br /> THERMOSTATIC CONTROLS SHALL PROVIDE A TEMPERATURE RANGE OR 120FT TO N LN CO RD TH N88.50 56W 559.78FT TO E LN CO RD TH N ALG CLASSROOM 110 1257 31 0.12 10 151 310 460 470 <br /> DEADBAND OF AT LEAST 5'F WITHIN WHICH THE SUPPLY OF HEATING AND SAID RD 893.08FT TO TPB EX ST OF WA 00377 170&169(SCHOOL-EVERETT PRO.I.NO: 2401 <br /> COOLING ENERGY TO THE ZONE IS CAPABLE OF BEING SHUT OFF OR MARY MAGDALEN) CLASSROOM 109 973 24 0.12 10 117 240 357 360 <br /> REDUCED TO A MINIMUM PER C403.2.4.1.2. DRAWN BY: BW <br /> CLASSROOM 108 1004 25 0.12 10 120 250 370 370 <br /> 2. EACH ZONE SHALL BE PROVIDED WITH THERMOSTATIC SETBACK CONTROLS CLASSROOM 107 1013 25 0.12 10 122 250 372 400 CHECKED BY: BW <br /> THAT ARE CONTROLLED BY EITHER AN AUTOMATIC TIME CLOCK OR p <br /> PROGRAMMABLE CONTROL SYSTEM. THERMOSTATIC SETBACK SHALL BE IN ^4,Q` V T-Hlgh school x \ w % CLASSROOM 106 1015 25 0.12 10 122 250 372 400 DATE: 4/15/2024 <br /> ACCORDANCE WITH C403.2.4.2.1 'fi+slMl Ave- i <br /> �' CLASSROOM 105 963 24 0.12 10 116 240 356 400 REVISIONS: <br /> 3. PROVIDE AUTOMATIC START CONTROLS FOR EACH HVAC SYSTEM. THE LIBRARY 141 1 35 0.06 5 85 175 260 260 <br /> CONTROLS SHALL BE CAPABLE OF AUTOMATICALLY ADJUSTING THE DAILY � Bellew A. ( ' <br /> START TIME OF THE HVAC SYSTEM IN ORDER TO BRING EACH SPACE TO READING 136 3 0.06 5 8 15 23 30 <br /> THE DESIRED OCCUPIED TEMPERATURE IMMEDIATELY PRIOR TO SCHEDULED . 536I ,i ,q I Br edw free <br /> OCCUPANCY IN ACCORDANCE WITH WSEC,C403.2.4.2.3 __ %I ._JI t I- ompa A/V WORKROOM 158 4 0.06 5 9 20 29 40 <br /> t EKteindad / CHECKOUT 144 4 0.06 5 9 20 29 40 <br /> 4. OUTDOOR AIR SUPPLY,EXHAUST OPENINGS AND RELIEF OUTLETS SHALL BE ECo sin.Rd 'j Stay Americp t� <br /> EQUIPPED WITH NOT LESS THAN CLASS 1 MOTORIZED DAMPERS IN R4M st 3f - eattle-... CONFERENCE 1 160 8 1 0.06 5 10 40 50 60 <br /> ACCORDANCE WITH WSEC,C403.2.4.3,AND SHALL BE INSTALLED WITH Fred Me er CORRIDOR 2 1153 --- 0.06 --- 69 --- 69 70 <br /> AUTOMATIC CONTROLS CONFIGURED TO CLOSE ALL OUTSIDE AIR,RELIEF Y Sunns, <br /> AND EXHAUST DAMPERS WHEN EQUIPMENT IS NOT RUNNING. 41nn.Lveren 4 Road <br /> ae. RECEPTION 226 6 0.06 5 14 30 44 50 <br /> iNER St Ma Magdalen 5. PROVIDE COMMISSIONING M THE MECHANICAL SYSTEM IN ACCORDANCE nt MOBILE \� d STORAGE 110 --- 0.06 --- --- --- --- --- <br /> pin A <br /> WITH C408. PROVIDE COMMISSIONING PLAN IN ACCORDANCE WITH Elementary School cypress WAITING 145 4 0.06 5 9 20 29 40 <br /> COUNTRY CLUB <br /> C408.1.2. PROVIDE FUNCTIONAL TESTING CRITERIA INCLUDING SEQUENCE Il Lewn w '� <br /> OF OPERATION,NEW AND EXISTING TO REMAIN INTERFACE AND TEST X1 Red G Cemetery. J i WORKROOM 177 4 0.06 5 11 20 31 40 <br /> PROCEDURES PER WASHINGTON STATE ENERGY CODE. ITEMS TO BE +Non,Nom o� 1 «d1f11$ <br /> COMMISSIONED ARE:ERV'S CABINET HEATERS,INDOOR AIR HANDLING UNITS, ✓TeriY ANDyaki N More - 1 FOYER 89 --- --- --- --- --- --- --- <br /> CONDENSING NITS AND BC Ul <br /> FINAL COMMISSIONING REPORTS.MSUBMT FIGURE C408ROLLER. PROVIDE R1.2.1I OMPLIANCE e9mstsL Readl ` - CORRIDOR 3 183 --- 0.06 --- 11 --- 11 20 SHEET TITLE <br /> CHECKLIST TO AUTHORITY HAVING JURISDICTION UPON COMPLETION OF FACULTY 282 7 0.06 5 17 35 52 60 <br /> PRELIMINARY COMMISSIONING REPORT. PROVIDE CLOSEOUT DOCUMENTS IN 8Cq MECHANICAL SYMBOLS, <br /> COMPLIANCE WITH C103.6. ALL COMMISSIONING REPORTS SHALL BE ! n HEALTH 114 3 0.06 5 7 15 22 30 NOTES AND LEGEND <br /> COMPLETED BY A COMMISSIONING PROFESSIONAL AND SHALL BE Auto 91atP -> OFFICE 208 5 0.06 5 12 25 37 40 <br /> COMPLETED PRIOR TO FINAL MECHANICAL INSPECTION. slay ^Walmart __ <br /> CASCADE VIEW 92nd st SE /'� .f. p RESTROOMS 693 --- - --- --- --- --- - <br /> 6. PURSUANT TO SECTION C408.2.3,FUNCTIONAL TESTING PERFORMANCE 4,� Y Supercenter 3 <br /> TESTING,THE HVAC SYSTEM SHALL BE TESTED TO ENSURE THAT THE sgeA CORRIDOR 1 1329 --- 0.06 --- 80 --- 80 80 <br /> Michaels Stereo snm Ai, <br /> SHEET NUMBER <br /> CONTROL DEVICES,EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED, '-° a s w.M10, vr,i _ <br /> AND OPERATE IN ACCORDANCE WITH THE APPROVED PLANS AND <br /> SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY <br /> TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THE APPROVED SITE PLAN <br /> PLANS AND SPECIFICATIONS. M <br /> curxr vwarcr xv <br />
The URL can be used to link to this page
Your browser does not support the video tag.