My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2121 W CASINO RD WSIPC 2024-12-30
>
Address Records
>
W CASINO RD
>
2121
>
WSIPC
>
2121 W CASINO RD WSIPC 2024-12-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2024 1:10:59 PM
Creation date
12/17/2024 11:04:44 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2121
Tenant Name
WSIPC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES <br /> 1. DEMOLISH EXISTING COOLING TOWER,SPRAY PUMP,CONTROL PANEL,DISCONNECT,AND VFD, ///...��� <br /> REMOVE FROM SITE AND DISPOSE OF. L U M IBC <br /> 2. DEMOLISH PIPING FROM COOLING TOWER UP TO POINT OF CONNECTION(POC)SYMBOL. <br /> 3. TEMPORARILY REMOVE&REPLACE CHAIN LINK FENCE SECTIONS AS NEEDED TO REMOVE <br /> COOLING TOWER. ATETn TECH COMPANY <br /> 4. PROVIDE NEW COOLING TOWER,SPRAY PUMP,FLANGED PIPE FLEX CONNECTOR,CONTROL engineers for a sustainable future- <br /> PANEL,DISCONNECT,AND VFD.PROVIDE HEAT TRACE ON ALL NEW PIPING PROVIDED. <br /> 5. EXISTING WATER TREATMENT SYSTEM TO REMAIN,INCLUDING CONTROLS,METERS&PIPING isoi Fmb—,S-22m <br /> CONNECTIONS. sease.wA 98101 <br /> 6. CONTRACTORTO PROVIDE A FUNCTIONAL TEMPORARY COOLING TOWER SYSTEM WITH w�wv.swmac.com <br /> TEMPORARY POWER FROM TIME OF THE START OF DEMOLITION UNTIL THE NEW COOLING Pr,*262.1010 <br /> Protect Manager:DeNayne Glenn <br /> TOWER CAN BE INSTALLED AND IS FULLY FUNCTIONAL.THE BID SHALL INCLUDE ALL PROVISIONS Job.No.:24U500135 <br /> To PROVIDE CONTINUOUS COOLING TO THE FACILITY DURING CONSTRUCTION INCLUDING BUT NOT <br /> LIMMIITTED TO;PLANNED LOATION FOR TEMPORARY TOWER,FLEX PIPING EXTENSIONS&POWER <br /> CONNECTION FROM EXISTING BUILDING. <br /> Client <br /> r � , <br /> 0(E)CHAIN LINK (E)CHAIN LINK I <br /> FENCE FENCE I `� <br /> r r W S I P C <br /> Inspired by education. <br /> (E)CONCRETE PAD \ (E)CONCRETE PAD Empowered by technology." <br /> I <br /> I I <br /> I I <br /> I I <br /> I I <br /> I I <br /> I I <br /> I Project <br /> I I <br /> I I <br /> WSIPC Cooling <br /> I Tower Replacement <br /> 1 ,T 6 4 'T 2121 W.Casino Road, <br /> (D) (N) I Everette,WA <br /> (E)WATER TREATMENT I 5 <br /> SYSTEM TO REMAIN <br /> I I <br /> I I <br /> I c I <br /> bb Mechanical <br /> Mechanical <br /> I I <br /> I I <br /> I I <br /> 2 <br /> E 1"C V T o9 <br /> (E)3"CWS <br /> (E)3"CWR r� I (E)3"CWR otsTe '0 <br /> NAL <br /> (E)CONDENSER WATER I (E)CONDENSER WATER <br /> &COLD WATER PIPING &COLD WATER PIPING <br /> BELOW GROUND BELOW GROUND <br /> TO/FROM MECHANICAL TO/FROM MECHANICAL <br /> ROOM ROOM Q2014-GLUMAC ALL RIGHTS RESERVED <br /> THESE DRAWINGS ARE THE PROPERTY OF <br /> GLUMAC ARE NOT TO BE <br /> USED OR REPRODUCED IN ANY MANNER, <br /> (D)VFD (D)DISCONNECT (D)CONTROL PANEL (N)VFD (N)DISCONNECT (N)CONTROL WITHOUT PRIOR WRITTEN PERMISSION <br /> O O O O ® PANEL <br /> Revisions <br /> # Description Date <br /> SHEET TITLE: <br /> ENLARGED <br /> PLANS <br /> DRAWN BY:DCG <br /> CHECKED BY:MA <br /> LEVEL 1 - ENLARGED MECHANICAL DEMOLITION PLAN - HVAC LEVEL 1 - ENLARGED MECHANICAL PLAN - HVAC SHEET <br /> SCALE:1/2"=V-0" L SCALE:112"=1'-0" NORTH M3.1 <br /> JOB NO.24US00135 <br /> Construction Documents 2/19/2024 <br />
The URL can be used to link to this page
Your browser does not support the video tag.