My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10902 17TH PL W 2025-01-06
>
Address Records
>
17TH PL W
>
10902
>
10902 17TH PL W 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 1:44:16 PM
Creation date
12/17/2024 11:38:06 AM
Metadata
Fields
Template:
Address Document
Street Name
17TH PL W
Street Number
10902
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SUPERHEAT <br /> Ambient Condenser Return Air Temperature( 50%RH ) <br /> Inlet Temperature Drybulb Wetbulb Drybulb Wetbulb Drybulb Wetbulb Drybulb Wetbulb Drybulb Wetbulb <br /> (°C Drybulb ) 18° 1 T 21° 14° 24° 17° 27° 19° 29° 22° <br /> 46 --- --- --- --- 3 <br /> 38 --- --- --- 3 3 <br /> 35 --- --- 3 3 5 <br /> 32 --- --- 3 6 6 <br /> 29 --- 3 3 7 9 <br /> 27 3 3 3 10 11 <br /> 24 3 3 6 11 12 <br /> 21 3 3 8 13 14 <br /> 18 3 6 11 14 16 <br /> 16 4 8 12 16 17 <br /> NOTE: * Charge 3° super heat, all other could be# 1.1°C <br /> TABLE IV -System Superheat <br /> A CAUTION 6. Turn the fan switch to the "Auto" position. The blower <br /> should stop 90 seconds later. <br /> To prevent personal injury, carefully connect and disconnect <br /> manifold gauge hoses. Escaping liquid refrigerant can cause Note: If outdoor temperature is below 12.8°C, proceed to <br /> burns. Do not vent refrigerant into the atmosphere. Recover step 9. Do not check out in the cooling mode. <br /> all refrigerant during system repair and before final unit <br /> dis osal. 7. Slowly lower the cooling temperature until the first mer- <br /> cury bulb makes contact.The compressor, indoor blower, <br /> HEAT PUMP HEATING CYCLE and outdoor fan should now be running. Make sure cool <br /> Weighing In Charge air is supplied by the unit. <br /> As in the cooling mode the proper method of insuring that the 8. Turn system switch to "Heat' and fan switch to "Auto". <br /> system is properly charged is by weight with the additional <br /> charge adjustments for line size, line length, and other system 9• Slowly raise the heating temperature setting.After the heat- <br /> components as previously indicated. ing first-stage mercury bulb (upper) makes contact, stop <br /> moving the lever.The compressor, indoor blower and out- <br /> STARTUP PROCEDURE AND CHECK LIST door fan should now be running. After giving the unit time <br /> Begin with power turned off at all disconnects. to settle out, make sure heated air is being supplied by <br /> 1. Set first-stage thermostat heat anticipator to .12 (amps) the indoor unit. <br /> and turn thermostat system switch to"Cool'and fan switch 10. If the outdoor ambient is above 21.1°C, the compressor <br /> to "Auto". may trip on internal overload. <br /> 2. Turn cooling temperature setting as high as it will go. 11. In the event that the outdoor ambient is too high to allow <br /> a thorough heating cycle check, postpone the test until <br /> 3. Inspect all registers and set them to the normal open po- another day when conditions are more suitable...but <br /> - <br /> sition. DO NOT FAIL TO TEST. <br /> 4. Turn on the unit electrical supply at the fused disconnect 12. If unit operates properly on the heating cycle, raise the <br /> switch, both for the indoor unit and the outdoor unit. heating temperature setting high enough until the heat- <br /> 5. Turn the fan switch to the"On"position.The blower should ing second-stage mercury bulb (lower) makes contact. <br /> operate 10 to 15 seconds later. <br /> 8 <br /> Downloaded from www.Manualslib.com manuals search enginc <br />
The URL can be used to link to this page
Your browser does not support the video tag.