For the location of your nearest distributor consult the white to the low side while the low side shell and suction line con- <br /> business pages,the yellow page section of the local telephone tains pressure, the pressurized refrigerant and oil mixture <br /> book or contact: could ignite when it escapes and contacts the brazing flame. <br /> CONSUMER AFFAIRS To prevent this occurrence , it is important to check both the <br /> GOODMAN MANUFACTURING COMPANY, L.P. high and low side with manifold gauge before unbrazing, <br /> 7401 SECURITY WAY bleed refrigerant from both the high and low side. <br /> HOUSTON, TEXAS 77040 IMPORTANT MESSAGE TO OWNER: <br /> 877-254-4729 These instructions should be carefully read and kept for <br /> NOTE: Information contained in this manual pertains only future reference. It is suggested that this booklet be saved <br /> to equipment intended for outdoor installation. For addi- for future references. It is addressed to your dealer and <br /> tional information refer to literature packaged with other serviceman, but we highly recommend you read it, paying <br /> system components. particular attention to the section titled MAINTENANCE. <br /> Pre-Installation Instructions The manufacturer assumes no responsibility for equipment <br /> Carefully read all instructions for the installation prior to in- installed in violation of any code or regulation. The manual <br /> stalling product. Make sure each step or procedure is under- will instruct you in the service and care of your unit. Have your <br /> stood and any special considerations are taken into account installer go over the manual with you so that you fully under- <br /> before starting installation. Assemble all tools, hardware and stand your air conditioner and how it is intended to function. <br /> supplies needed to complete the installation.Some items may The heat pump is a relatively simple device. It operates <br /> need to be purchased locally. Make sure everything needed exactly as a summer air conditioning unit on the cooling <br /> to install the product is on hand before starting. cycle. Always let the thermostat control system operation. <br /> Do Not try to second guess the thermostat or tamper with it. <br /> INSTALLATION AND OPERATING INFORMATION If the conditioned area temperature is not suitable, change <br /> FOR UNITS WITH SCROLL COMPRESSORS the thermostat setting one degree at a time until desired <br /> comfort level is achieved. <br /> ACAUTION A heat pump in the heating mode cannot heat a building as <br /> Use care when handling scroll compressors. Dome temp- rapidly as a furnace heats it. It may take a day or two to"pull <br /> eratures could be hot. down"a cold, moist house when the unit is initially installed <br /> The following information should be read prior to installing or after prolonged shutdowns. <br /> units with scroll compressors. MAINTENANCE <br /> 1. PUMP DOWN PROCEDURE It is recommended that the outdoor unit be inspected and, if <br /> necessary, cleaned each cooling season. Particular atten- <br /> A CAUTION tion should be given to the air inlet side of the outdoor coil to <br /> insure that leaves, grass, etc., are not being drawn into the <br /> Scroll compressors should never be used to evacuate the unit. Restriction to air flow across the coil will result in loss of <br /> air conditioning system.Vacuums this low can cause inter- system capacity, high operating pressures and excessive <br /> nal electrical arcing resulting in a damaged or failed compressor. <br /> operating costs. If the outdoor unit is installed adjacent to a <br /> 2. CRANKCASE HEATER grassy area, it is suggested that lawn mowers be routed in <br /> Heat pump models with scroll compressors may require a such a manner that the discharge of the mower will be di- <br /> crankcase heater. rected away from the unit. There must be air filters installed <br /> 3. TIME DELAY COMPONENT in the system at some point upstream to the indoor coil. Air <br /> filters should be inspected and, if necessary, replaced and/ <br /> The time delay is located in the low voltage control circuit. or cleaned AT LEAST once a month. <br /> When the compressor shuts off due to thermostat operation <br /> or a power failure,this components keeps the compressor off If disposable filters are used, an adequate supply of clean, <br /> for at least 30 seconds which allows the system pressure to unused filters of the correct size should be kept available. <br /> equalize. Equipment should never be operated without filters. <br /> 4. UNBRAZING SYSTEM COMPONENTS <br /> If the refrigerant charge is removed from a scroll equipped Permanent type filters may be vacuumed and/or washed but <br /> unit by bleeding the high side only, it is sometimes possible should not be reinstalled until thoroughly dry. Most air filters <br /> for the scrolls to seal,preventing pressure equalization through are marked to indicate the direction of airflow,and this should <br /> the compressor. This may leave the low side shell and suc- be carefully noted when they are being installed. Never turn <br /> tion line tubing pressurized. If a brazing torch is then applied a dirty filter to allow air flow in the opposite direction. <br /> 2 <br /> Downloaded from www.Manualslib.com manuals search engine <br />