SUBMITTAL AR18CSFCMWKNCV/AR18CSFCMWKXCV Page 1 of4 <br /> S n M S u N G <br /> Samsung WindFreeTM* 3.0e, wall mounted evaporator, split system <br /> Job Name Location <br /> Purchaser Engineer <br /> Submitted to Reference Approval 0 Construction 0 <br /> Unit Designation Schedule# <br /> Specifications <br /> Model Indoor Unit Model Number(US Code) AR18CSFCMWKNCV(RNSI8CMC) <br /> Outdoor Unit Model Number(US Code) AR18CSFCMWKXCV(RXSI8CMC) <br /> Nominal Capacity Cooling/Heating(Btu/h) 18,000/21,000 _`\\� S A M S tl P.! <br /> Capacity Range <br /> Cooling(Btu/h) 5,500-22,000 �� ����\ <br /> �\\w� <br /> Performance Heating(Btu/h) 4,000-26,000 i' w? \1INU, <br /> SEER2/EER2 18.7/ <br /> HSPF2 8.0 I i� <br /> Voltage e/V/Hz 1/208-230/60 <br /> Working Voltage Range(VAC) 187-253 <br /> Power Operating Current Cooling(A) 2.0/7.4/9.2 m <br /> (min./std./max.) Heating(A) 2.2/8.2/10.1 (actual equipment appearance may vary) <br /> Max.Breaker Amps 25 <br /> General Information <br /> Min.Circuit Ampacity(A) 16 The indoor unit shall feature WindFree-*mode.In cooling mode,as room temperature nears <br /> Indoor Unit 41-9/16 x 11-3/4 x 8-7/16 set temperature,the unit will close its louver and will disperse air into the space through <br /> W X H X D(in.) Outdoor Unit 34-5/8 x 25-1/8 x 12-3/16 thousands of micro-holes on the front of the indoor unit preventing cold air drafts on occupants. <br /> Dimensions •Indoor Unit 25.4 The indoor unit shall have Wi-Fi capability as standard. <br /> Weight(Ibs.) • Outdoor unit shall provide 208/230V power to indoor unit via 14 AWG X 3 interconnect power <br /> Outdoor Unit 87.1 cable. <br /> Indoor Unit dB(A) H/Silent 41/27 <br /> Sound Pressure Level Construction <br /> Outdoor Unit dB(A) High 51 Indoor unit chassis shall be UL94 VO with a galvanized steel mounting bracket <br /> Outdoor Cooling 14-115°F(A0-46°C) The indoor unit shall have easy-access to wire,pipe,and drain connections via access panel <br /> Heating -5-75°F(-20.5-24°C) on the bottom of the unit for simple installation and service <br /> Operating Temperatures • The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability <br /> Indoor Cooling 61-90°F(16-32°C) 9 <br /> Heating 50-86°F(27-30°C) Heat Exchanger <br /> Indoor&Outdoor High side(flare) 1/4" . The heat exchangers shall be mechanically bonded fin to copper tube <br /> Low side(flare) 1/2" <br /> Pipe Connections Maximum(ft.) 98 Refrigerant System <br /> The compressor shall be hermetically sealed,inverter controlled,BLDC Rotary <br /> Maximum Vertical Separation(ft.) 66 Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit <br /> Condensate Connection 11/16"OD <br /> Type R410A Indoor Fan <br /> Control Method Electronic Expansion Valve • The indoor fan shall be a single,antibacterial cross-flow type <br /> • Three fan speed settings and auto setting <br /> Refrigerant Factory Charge lbs. 2.87 . Automatic(motorized)vertical swing(up/down)and horizontal swing(left/right)louvers <br /> Charge for 25 ft. <br /> Additional Refrigerant Charge 0.16 oz./ft.over 25 ft. Controls <br /> • The system shall have a built in Wi-Fi adapter as standard to allow control and monitoring using <br /> Manufacturer Samsung the Samsung SmartThings app(Android,iOS) <br /> Compressor Type BLDC Rotary • Dual set temperature support when connected to MWR-WGOOUN Advanced Wired Controller. <br /> RLA Amps 15.2 The indoor unit shall have a simple connection for overflow detection devices or any other <br /> normally closed contact for simple unit shutdown <br /> Type BLDC motor with cross-flow fan The indoor unit shall ship with a wireless controller,holder,and batteries <br /> Air Volume Cooling(CFM) 445/494/540/586 • Wired controller options available <br /> Evaporator Fan • Samsung central control compatible(MIM-R10UN accessory required) <br /> (UM/H/Turbo) Heating(CFM) 4451494/540/586 Interconnect control wire between outdoor and indoor unit shall be 16AWG X 2 <br /> Output Watts 27 <br /> FLA Watts 0.12 Convenience <br /> . System energy consumption can be viewed using the Samsung SmartThings mobile app or on <br /> Motor BLDC With Axial Type Fan(1) the indoor unit display using the included wireless controller** <br /> Output Watts 40 . Al(artificial intelligence)Auto Mode technology monitors factors such as indoor temperature, <br /> Condenser Fan outdoor temperature,set temperature,and operating time to learn the patterns within our <br /> FLA Amps 0.48 P P P 9 P Y <br /> Air Volume CFM(max.) 1766 home to automatically adjust system operation to maximize occupant comfort and efficiency <br /> (Wi-Fi connection required) <br /> Certifications UL 60335-2-40 . Eco Mode to reduce energy consumption during low demand operation <br /> PCB fuses,indoor unit terminal block thermal fuse,current • Smart install mode-startup system diagnostics operation to ensure system readiness during <br /> Safety operation <br /> Devices transformer,over-voltage protection,crankcase heating, initial o P <br /> temperature limit protection logic,compressor overload sensing • Auto restart <br /> . Auto Clean Function <br /> 'Certified in accordance with the AHRI Unitary Small Air-Source Heat Pumps(USHP)Certification Program which is . Freeze Wash Function <br /> based on the latest edition of AHRI Standard 210/240. • 7-segment digital display on front of unit to display temperature and unit status <br /> • "Fast"mode to quickly reach set temperature <br /> *The WindFreeM unit delivers an air current that is under 0.15 m/s while in WindFreeM mode. Air velocity that is . Auto changeover <br /> below 0.15 m/s is considered"still air'as defined by ASHRAE(American Society of Heating,Refrigeranting,and Air Good sleep mode <br /> Conditioning Engineers). • Quiet mode <br /> Samsung HVAC maintains a policy of ongoing development. Specifications are subject to change without notice. • Dry mode <br /> Refer to www.AHRldirectorv.org for current reference numbers. Simple ON/OFF time function-Using the wireless controller specify the ON and/or OFF times <br /> • Electro-static,washable,main filter as standard accessible from the top of unit <br /> • Filter cleaning reminder <br /> ftlaySmdAC. 1;0%, us <br /> ©2023 Samsung HVAC <br /> Intertek www.SamsungHVAC.com SHA-RAC-RXS18CMCRNS18CMC-2301A <br />