Laserfiche WebLink
REVISIONS BY <br /> GENERAL NOTES: <br /> I. VERIFY DIMENSIONS SHOWN ON PLANS.DO NOT SCALE OFF PLAN COPY. NEW 1 <br /> EXISTING WALLS DIMENSIONED TO EDGE OF PLATE TYPICAL <br /> 2, FRAME NEW INTERIOR/EXTERIOR WALLS®ADDITION W/2.4 STUDS(VERIFY LENGTH) SEAM SCHEDULE <br /> ®16"O.G.TYP.(MATCH EXIST.PLATE HEIGHT) <br /> 3. DOORS THAT ARE NOT DIMENSIONED TO HAVE 1W0 STUDS(3")BTWN.ROUGH OPNG, <br /> DINING ROOM BEAM• SIZE 1 TYPE REMARKS <br /> AND NEAREST PERPENDICULAR WALL. IF EXIST.BEDROOM WINDOWS REPLACED 4.4 HF"2 <br /> VERIFY EGRESS WINDOW DIMENSIONS,CLEAR OPENING 1 SILL HEIGHT COMPLY W/ ZL <br /> IRC SECTION 310(MIN.5.1 S.F.NET CLR.OPNG.,MIN,24"OPNG.HGT.,MIN,20"OPNG, <br /> WIDTH,MAX.44"FINISHED SILL HGT,). VERIFY SPECS.WITH WINDOW SUPPLIER AND/ Al 4x6 HF"2 <br /> OR MANUFACTURER <br /> 3 4.10 DF-L"2 <br /> 4. INSTALL I/2"GYPSUM WALLBOARD INTERIOR SIDE OF NEW EXTERIOR WALLS a BOTH <br /> SIDES OF NEW INTERIOR WALLS N.N.O.BY OWNER AND/OR BUILDER). INSTALL 5/8" LIVING ROOM <br /> TYPE-X GUS®GARAGE SIDE OF GARAGE/HOUSE WALLS. INSTALL 20-MINUTE RATED <br /> DOOR ASSEMBLY STUN.HOUSE 1 GARAGE W/SELF-CLOSING HARDWARE <br /> i <br /> 5. DIMENSIONAL LUMBER TO BE HEM-FIR+2 TYPICAL(U.N.O.). UNLESS NOTED OTHERWISE <br /> USE 4x4 HF"2 HEADER IN EXTERIOR WALLS ABV,DOORS/WDWS.(NOTE:HEARTWOOD Q <br /> BEAMS ARE NOT TO BE USED W/4x DEPTH). BEAMS AND HEADERS TO HAVE 1 1/2" 'w <br /> MIN.BEARING TYP.U.N.O. (BMS.SHOWN ARE MIN.REQ'D OR BETTER-SIZE AND/OR V 4y <br /> GRADE MAY BE INCREASED PER BUILDER'S DISCRETION). DESIGNER SHOULD BE 1 <br /> CONSULTED REGARDING ANY CHANGES TO PLAN MADE DURING CONSTRUCTION SINCE r\rnn i lwIII <br /> STRUCT.MEMBERS ARE SIZED FOR THEIR SPECIFIC LOCATION/LOADS SUPPORTED ® KITCHEN v+ y <br /> 6. COMPLIANCE DATA FOR THE 2018 WASHINGTON STATE ENERGY CODE IS AS FOLLOWS: -- 5'-1"t/- 25'!°�/- <br /> SLAB: R-10 RIG W <br /> ID INSULATION®SLAB PERIMETER/BELOW ENTIRE SLAB i O � <br /> "CONDITIONED AREAS) - <br /> EXTERIOR WALLS: R-21(SPRAY-FOAM NEW EXTERIOR WALLS a INFILLED OPNGS,o -I- R t <br /> J� <br /> EXIST.WALLS--MIN.R-6 PER INCH) i Vi <br /> NEW CEILING: R-49 --- Lj <br /> DOOR TO GARAGE: U=300 MAX.(ONE OPAQUE DOOR UP TO 24 S.F.EXEMPT) � Z WINDOWS: U=.280 MAX.(NEW a REPLACED WOWS.,ONE WDW.UP TO 15 S.F. i 0 <br /> EXEMPT) <br /> EXISTING FLOOR: R-30 WHERE EXIST,INSUL.DISTURBED BY CONSTRUCTION ' h <br /> EXIST.EXT.WALLS: R-11 ASSUMED <br /> EXIST.CEILING: R-49 WHERE EXIST.INSUL.DISTURBED BY CONSTRUCTION 1 <br /> ADDITIONAL ENERGY EFFICIENCY REQ'MENTS PER WSEC SEC.R406(ADDITIONS LESS 1 J Q Q <br /> THAN OR EQUAL TO SOO S,F,:1,5 CREDITS)ARE AS FOLLOWS: 1 y <br /> SYSTEM TYPE 4:FOR HEATING SYSTEM BASED ON ELECTRIC RESISTANCE WITH A <br /> DUCTLESS MINISPLIT HEAT PUMP SYSTEM IN ACCORDANCE WITH 1 <br /> SECTION R403.1.1 INCLUDING THE EXCEPTION:0.5 CREDITS « M 0 O <br /> OPTION 1.3:VERTICAL FENESTRATION U=0,28,SLAB ON GRADE R-10 PERIMETER 1 FAMILY ROOM 1 3-O W W <br /> UNDER ENTIRE SLAB:0.5 CREDITS <br /> OPTION 2.11 REDUCE THE TESTED AIR LEAKAGE TO 3.0 AIR CHANGES PER HOUR 'p <br /> MAXIMUM AT 50 PASCALS:0.5 CREDITS LAU IRY '_3 2-CAR GARAGE 2 o. <br /> GLAZING TOTAL: EXISTING REMOVED/REPLACED:3.0 S.F.NET DECREASE Q m <br /> PROPOSED:35.0 S.F,(8.1`:e OF GROSS FLR.AREA ADDED) .9 RELOCATE EXIST.ATTIC a._ <br /> VERIFY INSULATION IS INSTALLED BEHIND PARTITIONS,IN CORNERS a FITTED AROUND 1 - - ACCESS(SEE NOTE"9) O fJ O <br /> WIRING, WHERE EXIST.INSULATION IS DISTURBED BY CONSTRUCTION REPLACE WITH <br /> 2018 WSEC REQ'D INSUL,R-VALUES(EXIST.INSUL.NEED NOT BE UPGRADED TO 2018 <br /> SEE b, i H 2 <br /> WSEC REQUIREMENTS IF UNDISTURBED). REFER TO 2018 WSEC CHAPTER 4 RESIDENTIAL <br /> ENERGY EFFICIENCY(CLIMATE ZONE 4C)FOR VERIFICATION OF ALL INSUL.VALUES a <br /> 1. STRUCTURAL DESIGN2 LOADING CALCULATED AS FOLLOWS: O �' W� 20'-514" �p <br /> ROOF: 25"PSF LIVE LOAD,35"PSF TOTAL LOAD U �ff O I, 4'-6" 0O r, �S <br /> WALL WEIGHT: 10"PSF TOTAL O V V <br /> p 11'2"a/ 4'2" 5-Ih" 2 <br /> FLOOR: 40+PSF LL,50"PSF TL I I q ' <br /> 8. INSTALL 6-MIL BLACK POLYETHYLINE CLASS I VAPOR RETARDER ON BARE GROUND BATH 03 BATH •I ti SEE NOTE"4 ' <br /> BEFORE POURING NEW SLAB a ON EXIST.GARAGE SLAB BEFORE INSTALLING RIGID ISTIN ,r`(j i <br /> INSUL,a BEFORE POURING NEW SLAB . H URNAC fJ <br /> 'n <br /> BATH 02 3.O SHELF a ROD <br /> 9, ATTIC ACCESS MIN.30"x 22"(VERIFY LOCATION). INSULATE ACCESS DOOR/HATCH TO 4x4 POST _9 <br /> ATTIC TO THE EQUIVALENT RATING OF THE INSULATED CEILING THROUGH WHICH IT 8n'/_ - ___ <br /> PENETRATES IF LOCATED IN CONDITIONED SPACE. MAINTAIN -HOUR CLG,RATING IF 3'-315" If-blh" ^� 4�2'rR.O. <br /> LOCATED IN GARAGE. VERIFY INSULATION DAMS ARE INSTALLED AROUND ATTICACCESS MAINTAIN 4x4 <br /> To <br /> BE NO LESS THAN 30 Z_ <br /> REQ'D INSUL.DEPTH. MIN.HEADROOM ABV.ATTIC ACCESS TO POST <br /> 10. MINIMUM EXHAUST FA CLEAR AT ANY POINT(ACCESS NOT RE NEW <br /> TO ATTICS W/LESS VE 3b SEE NOTE"3 X z <br /> _N <br /> THAN 30'CLEARANCE). VERIFY OPNG.BTWN.EXIST.ATTIC 1 NEW ATTIC FOR ACCESS =___= ABOVE-SEE _________ _ W <br /> N SIZES REQ'D TO COMPLY WITH THE WASHINGTON STATE vENTI- -------- 4.4 POST®BEARING Z O <br /> ________ ;Vn <br /> LATION AND INDOOR AIR QUALITY(VIAQ)CODE ARE AS FOLLOWS: SEE NOTE"12 POINTS OF NEW GIRDER <br /> LAUNDRY ROOM: 50 CFM(80 CFM RECOMMENDED) « N TRUSS(2 LOCATIONS) <br /> BEE NOTE"II <br /> NOTE:ALL FANS ON 20-MINUTE TIMER TYPICAL. VERIFY PROPER INSTALLATION OF � _ � Q M O <br /> BAFFLES TO MAINTAIN REQ'D VENT OPNGS.IN CEILING. UNDERCUT INTERIOR DOORS lQ BEDROOM •6 BEDROOM •B W m N <br /> TO ALLOW FOR AIR MOVEMENT. SEE ELECTRICAL PLAN ON SHEET 6 FOR LOCATION 1 <br /> OF EXHAUST FAN(VERIFY ALL EXHAUST FAN VENT DUCTS TERMINATE AT EXTERIOR $DRM. •3 s, iyI lid - 0 z <br /> OF BUILDING,TYP.) BEDROOM "I s �, 11`v LU <br /> a N ~ <br /> II. RELOCATE EXISTING GAS METER TO EAST SIDE OF PROPOSED ADDITION(VERIFY WITH SEE NOTE"4 0 w <br /> OWNER,BUILDER AND GAS COMPANY) ,0 <br /> 12, REMOVE EXIST.BEARING WALL AFTER EXIST.RAFTERS a TRUSSES HAVE BEEN HUNG - 102 y 2 <br /> FROM NEW GIRDER TRU55(SEE ROOF FRAMING PLAN ON SHT.5) _ yy ■i IF" ` <br /> 13. RELOCATE EXISTING DRYER VENT TO EXTERIOR m W 5- 5036 XO 5036 XO O /�' <br /> _ W EG ESS EGRESS <br /> > UI <br /> N <br /> O2'-10 �15" 3'-10" 4'-6" 4'-915" Z LU �- <br /> 2' w <br /> Lu <br /> w <br /> BEDROOM w2 BEDROOM 04 (L <br /> OED No <br /> I I N <br /> I I II K — <br /> I <br /> (V <br /> I I I I l(1 <br /> I I 11 1—y <br /> I I <br /> I I <br /> EXISTING PROPOSED TOTALS FLOOR FLAN^N PL4N \ C ZUPL <br /> NORTH \ ACCUPLAN CUSTOM <br /> LIVING SPACE 1,962 S.F. +432 S.F. 2,394 S.F. SCALE: 1/4" • 1'-0" SU/LO/NG DES/ON <br /> \ DRAWN BY <br /> GARAGE 111 S.F. -242 5,F, 469 S.F. O EXISTING WALLS BJ <br /> REMOVED WALLS DATE <br /> NEW WALLS JULY 14,2023 <br /> DESIGNER HAS TAKEN CARE TO VERIFY THE ACCURACY OF THESE PLANS, IT IS <br /> THE BUILDER'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS PRIOR TO STARTING JOB NUMBER <br /> CONSTRUCTION AND TO VERIFY EXISTING STRUCTURAL CONDITIONS PRIOR TO 2315 <br /> STARTING ANY DEMOLITION. BUILDER TO VERIFY SHORING OF ALL STRUCTURAL <br /> COMPONENTS WHERE AFFECTED BY REMODEL. ALL CONSTRUCTION SHALL COMPLY SWEET <br /> WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE(/ASSOCIATED ADOPTED CODES), <br /> 2018 WASHINGTON STATE ENERGY CODE,AND ALL APPLICABLE LOCAL,STATE AND <br /> FEDERAL BUILDING GODES THAT HAVE BEEN LAWFULLY ADOPTED BY THE BUILDING <br /> DEPARTMENT OF JURISDICTION. DESIGNER IS NOT RESPONSIBLE FOR ANY CHANGES <br /> MADE TO THESE PLANS BY OTHERS OR BY THE BUILDER ON-SITE 4 <br /> OF SEVEN SHEETS <br />