<br /> GENERAL NOTES:
<br /> I. VERIFY DIMENSIONS SHOWN ON PLANS.DO NOT SCALE OFF PLAN COPY. NEW 1
<br /> EXISTING WALLS DIMENSIONED TO EDGE OF PLATE TYPICAL
<br /> 2, FRAME NEW INTERIOR/EXTERIOR WALLS®ADDITION W/2.4 STUDS(VERIFY LENGTH) SEAM SCHEDULE
<br /> ®16"O.G.TYP.(MATCH EXIST.PLATE HEIGHT)
<br /> 3. DOORS THAT ARE NOT DIMENSIONED TO HAVE 1W0 STUDS(3")BTWN.ROUGH OPNG,
<br /> DINING ROOM BEAM• SIZE 1 TYPE REMARKS
<br /> AND NEAREST PERPENDICULAR WALL. IF EXIST.BEDROOM WINDOWS REPLACED 4.4 HF"2
<br /> VERIFY EGRESS WINDOW DIMENSIONS,CLEAR OPENING 1 SILL HEIGHT COMPLY W/ ZL
<br /> IRC SECTION 310(MIN.5.1 S.F.NET CLR.OPNG.,MIN,24"OPNG.HGT.,MIN,20"OPNG,
<br /> WIDTH,MAX.44"FINISHED SILL HGT,). VERIFY SPECS.WITH WINDOW SUPPLIER AND/ Al 4x6 HF"2
<br /> OR MANUFACTURER
<br /> 3 4.10 DF-L"2
<br /> 4. INSTALL I/2"GYPSUM WALLBOARD INTERIOR SIDE OF NEW EXTERIOR WALLS a BOTH
<br /> SIDES OF NEW INTERIOR WALLS N.N.O.BY OWNER AND/OR BUILDER). INSTALL 5/8" LIVING ROOM
<br /> TYPE-X GUS®GARAGE SIDE OF GARAGE/HOUSE WALLS. INSTALL 20-MINUTE RATED
<br /> DOOR ASSEMBLY STUN.HOUSE 1 GARAGE W/SELF-CLOSING HARDWARE
<br /> i
<br /> 5. DIMENSIONAL LUMBER TO BE HEM-FIR+2 TYPICAL(U.N.O.). UNLESS NOTED OTHERWISE
<br /> USE 4x4 HF"2 HEADER IN EXTERIOR WALLS ABV,DOORS/WDWS.(NOTE:HEARTWOOD Q
<br /> BEAMS ARE NOT TO BE USED W/4x DEPTH). BEAMS AND HEADERS TO HAVE 1 1/2" 'w
<br /> MIN.BEARING TYP.U.N.O. (BMS.SHOWN ARE MIN.REQ'D OR BETTER-SIZE AND/OR V 4y
<br /> GRADE MAY BE INCREASED PER BUILDER'S DISCRETION). DESIGNER SHOULD BE 1
<br /> CONSULTED REGARDING ANY CHANGES TO PLAN MADE DURING CONSTRUCTION SINCE r\rnn i lwIII
<br /> STRUCT.MEMBERS ARE SIZED FOR THEIR SPECIFIC LOCATION/LOADS SUPPORTED ® KITCHEN v+ y
<br /> 6. COMPLIANCE DATA FOR THE 2018 WASHINGTON STATE ENERGY CODE IS AS FOLLOWS: -- 5'-1"t/- 25'!°�/-
<br /> SLAB: R-10 RIG W
<br /> ID INSULATION®SLAB PERIMETER/BELOW ENTIRE SLAB i O �
<br /> "CONDITIONED AREAS) -
<br /> EXTERIOR WALLS: R-21(SPRAY-FOAM NEW EXTERIOR WALLS a INFILLED OPNGS,o -I- R t
<br /> J�
<br /> EXIST.WALLS--MIN.R-6 PER INCH) i Vi
<br /> NEW CEILING: R-49 --- Lj
<br /> DOOR TO GARAGE: U=300 MAX.(ONE OPAQUE DOOR UP TO 24 S.F.EXEMPT) � Z WINDOWS: U=.280 MAX.(NEW a REPLACED WOWS.,ONE WDW.UP TO 15 S.F. i 0
<br /> EXEMPT)
<br /> EXISTING FLOOR: R-30 WHERE EXIST,INSUL.DISTURBED BY CONSTRUCTION ' h
<br /> EXIST.EXT.WALLS: R-11 ASSUMED
<br /> EXIST.CEILING: R-49 WHERE EXIST.INSUL.DISTURBED BY CONSTRUCTION 1
<br /> ADDITIONAL ENERGY EFFICIENCY REQ'MENTS PER WSEC SEC.R406(ADDITIONS LESS 1 J Q Q
<br /> THAN OR EQUAL TO SOO S,F,:1,5 CREDITS)ARE AS FOLLOWS: 1 y
<br /> SYSTEM TYPE 4:FOR HEATING SYSTEM BASED ON ELECTRIC RESISTANCE WITH A
<br /> DUCTLESS MINISPLIT HEAT PUMP SYSTEM IN ACCORDANCE WITH 1
<br /> SECTION R403.1.1 INCLUDING THE EXCEPTION:0.5 CREDITS « M 0 O
<br /> OPTION 1.3:VERTICAL FENESTRATION U=0,28,SLAB ON GRADE R-10 PERIMETER 1 FAMILY ROOM 1 3-O W W
<br /> UNDER ENTIRE SLAB:0.5 CREDITS
<br /> OPTION 2.11 REDUCE THE TESTED AIR LEAKAGE TO 3.0 AIR CHANGES PER HOUR 'p
<br /> MAXIMUM AT 50 PASCALS:0.5 CREDITS LAU IRY '_3 2-CAR GARAGE 2 o.
<br /> GLAZING TOTAL: EXISTING REMOVED/REPLACED:3.0 S.F.NET DECREASE Q m
<br /> PROPOSED:35.0 S.F,(8.1`:e OF GROSS FLR.AREA ADDED) .9 RELOCATE EXIST.ATTIC a._
<br /> VERIFY INSULATION IS INSTALLED BEHIND PARTITIONS,IN CORNERS a FITTED AROUND 1 - - ACCESS(SEE NOTE"9) O fJ O
<br /> WIRING, WHERE EXIST.INSULATION IS DISTURBED BY CONSTRUCTION REPLACE WITH
<br /> 2018 WSEC REQ'D INSUL,R-VALUES(EXIST.INSUL.NEED NOT BE UPGRADED TO 2018
<br /> SEE b, i H 2
<br /> WSEC REQUIREMENTS IF UNDISTURBED). REFER TO 2018 WSEC CHAPTER 4 RESIDENTIAL
<br /> ENERGY EFFICIENCY(CLIMATE ZONE 4C)FOR VERIFICATION OF ALL INSUL.VALUES a
<br /> 1. STRUCTURAL DESIGN2 LOADING CALCULATED AS FOLLOWS: O �' W� 20'-514" �p
<br /> ROOF: 25"PSF LIVE LOAD,35"PSF TOTAL LOAD U �ff O I, 4'-6" 0O r, �S
<br /> WALL WEIGHT: 10"PSF TOTAL O V V
<br /> p 11'2"a/ 4'2" 5-Ih" 2
<br /> FLOOR: 40+PSF LL,50"PSF TL I I q '
<br /> 8. INSTALL 6-MIL BLACK POLYETHYLINE CLASS I VAPOR RETARDER ON BARE GROUND BATH 03 BATH •I ti SEE NOTE"4 '
<br /> BEFORE POURING NEW SLAB a ON EXIST.GARAGE SLAB BEFORE INSTALLING RIGID ISTIN ,r`(j i
<br /> INSUL,a BEFORE POURING NEW SLAB . H URNAC fJ
<br /> 'n
<br /> BATH 02 3.O SHELF a ROD
<br /> 9, ATTIC ACCESS MIN.30"x 22"(VERIFY LOCATION). INSULATE ACCESS DOOR/HATCH TO 4x4 POST _9
<br /> ATTIC TO THE EQUIVALENT RATING OF THE INSULATED CEILING THROUGH WHICH IT 8n'/_ - ___
<br /> PENETRATES IF LOCATED IN CONDITIONED SPACE. MAINTAIN -HOUR CLG,RATING IF 3'-315" If-blh" ^� 4�2'rR.O.
<br /> LOCATED IN GARAGE. VERIFY INSULATION DAMS ARE INSTALLED AROUND ATTICACCESS MAINTAIN 4x4
<br /> To
<br /> BE NO LESS THAN 30 Z_
<br /> REQ'D INSUL.DEPTH. MIN.HEADROOM ABV.ATTIC ACCESS TO POST
<br /> 10. MINIMUM EXHAUST FA CLEAR AT ANY POINT(ACCESS NOT RE NEW
<br /> TO ATTICS W/LESS VE 3b SEE NOTE"3 X z
<br /> _N
<br /> THAN 30'CLEARANCE). VERIFY OPNG.BTWN.EXIST.ATTIC 1 NEW ATTIC FOR ACCESS =___= ABOVE-SEE _________ _ W
<br /> N SIZES REQ'D TO COMPLY WITH THE WASHINGTON STATE vENTI- -------- 4.4 POST®BEARING Z O
<br /> ________ ;Vn
<br /> LATION AND INDOOR AIR QUALITY(VIAQ)CODE ARE AS FOLLOWS: SEE NOTE"12 POINTS OF NEW GIRDER
<br /> LAUNDRY ROOM: 50 CFM(80 CFM RECOMMENDED) « N TRUSS(2 LOCATIONS)
<br /> BEE NOTE"II
<br /> NOTE:ALL FANS ON 20-MINUTE TIMER TYPICAL. VERIFY PROPER INSTALLATION OF � _ � Q M O
<br /> BAFFLES TO MAINTAIN REQ'D VENT OPNGS.IN CEILING. UNDERCUT INTERIOR DOORS lQ BEDROOM •6 BEDROOM •B W m N
<br /> TO ALLOW FOR AIR MOVEMENT. SEE ELECTRICAL PLAN ON SHEET 6 FOR LOCATION 1
<br /> OF EXHAUST FAN(VERIFY ALL EXHAUST FAN VENT DUCTS TERMINATE AT EXTERIOR $DRM. •3 s, iyI lid - 0 z
<br /> OF BUILDING,TYP.) BEDROOM "I s �, 11`v LU
<br /> a N ~
<br /> II. RELOCATE EXISTING GAS METER TO EAST SIDE OF PROPOSED ADDITION(VERIFY WITH SEE NOTE"4 0 w
<br /> OWNER,BUILDER AND GAS COMPANY) ,0
<br /> 12, REMOVE EXIST.BEARING WALL AFTER EXIST.RAFTERS a TRUSSES HAVE BEEN HUNG - 102 y 2
<br /> FROM NEW GIRDER TRU55(SEE ROOF FRAMING PLAN ON SHT.5) _ yy ■i IF" `
<br /> 13. RELOCATE EXISTING DRYER VENT TO EXTERIOR m W 5- 5036 XO 5036 XO O /�'
<br /> _ W EG ESS EGRESS
<br /> > UI
<br /> N
<br /> O2'-10 �15" 3'-10" 4'-6" 4'-915" Z LU �-
<br /> 2' w
<br /> Lu
<br /> w
<br /> BEDROOM w2 BEDROOM 04 (L
<br /> OED No
<br /> I I N
<br /> I I II K —
<br /> I
<br /> (V
<br /> I I I I l(1
<br /> I I 11 1—y
<br /> I I
<br /> I I
<br /> EXISTING PROPOSED TOTALS FLOOR FLAN^N PL4N \ C ZUPL
<br /> NORTH \ ACCUPLAN CUSTOM
<br /> LIVING SPACE 1,962 S.F. +432 S.F. 2,394 S.F. SCALE: 1/4" • 1'-0" SU/LO/NG DES/ON
<br /> \ DRAWN BY
<br /> GARAGE 111 S.F. -242 5,F, 469 S.F. O EXISTING WALLS BJ
<br /> REMOVED WALLS DATE
<br /> NEW WALLS JULY 14,2023
<br /> DESIGNER HAS TAKEN CARE TO VERIFY THE ACCURACY OF THESE PLANS, IT IS
<br /> THE BUILDER'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS PRIOR TO STARTING JOB NUMBER
<br /> CONSTRUCTION AND TO VERIFY EXISTING STRUCTURAL CONDITIONS PRIOR TO 2315
<br /> STARTING ANY DEMOLITION. BUILDER TO VERIFY SHORING OF ALL STRUCTURAL
<br /> COMPONENTS WHERE AFFECTED BY REMODEL. ALL CONSTRUCTION SHALL COMPLY SWEET
<br /> WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE(/ASSOCIATED ADOPTED CODES),
<br /> 2018 WASHINGTON STATE ENERGY CODE,AND ALL APPLICABLE LOCAL,STATE AND
<br /> FEDERAL BUILDING GODES THAT HAVE BEEN LAWFULLY ADOPTED BY THE BUILDING
<br /> DEPARTMENT OF JURISDICTION. DESIGNER IS NOT RESPONSIBLE FOR ANY CHANGES
<br /> MADE TO THESE PLANS BY OTHERS OR BY THE BUILDER ON-SITE 4