My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5009 SEAHURST AVE 2025-04-17
>
Address Records
>
SEAHURST AVE
>
5009
>
5009 SEAHURST AVE 2025-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 1:32:59 PM
Creation date
12/18/2024 1:08:26 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAHURST AVE
Street Number
5009
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R330.8.3.1 Fixed position grab bars.Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from <br /> the rear wall. <br /> R330.8.3.2 Swing-up grab bars.Swing-up grab bars shall be a minimum of 28 inches in length from the rear wall. <br /> R330.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R330.8. <br /> R330.8.4.1 Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and <br /> head end wall.Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub.The <br /> bottom end of the bar shall start between 36 inches and 42 inches above floor grade. <br /> EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the <br /> requirements of R330.8 at the control end and head end entry points. <br /> R330.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end,and the back wall within the <br /> bathtub area.Grab bars shall be mounted between 33 inches and 36 inches above floor grade.Control end and head end grab bars <br /> shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. <br /> R330.8.5 Grab bars at shower stalls.Where shower stalls are provided to meet the requirements for bathing facilities,grab bars <br /> shall meet the requirements of R330.8. <br /> EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab <br /> bars at the seat end wall.A vertical floor to ceiling grab bar shall be installed within 4 inches of <br /> the exterior of the shower aligned with the nose of the built-in seat. <br /> R330.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and <br /> head end wall.Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower <br /> stall.The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. <br /> R330.8.5.2 Horizontal grab bars.Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 <br /> inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal <br /> grab bars shall not interfere with shower control valves. <br /> R330.9 Ramps.All interior and exterior ramps,when provided,shall be constructed in accordance with Section R311.8 with a <br /> maximum slope of 1 vertical to 12 horizontal.The exception to R311.8.1 is not allowed for adult family homes.Handrails shall be <br /> installed in accordance with R330.9.1. <br /> R330.9.1 Handrails for ramps.Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal <br /> and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. <br /> R330.10 Stair treads and risers.Stair treads and risers shall be constructed in accordance with R311.7.5.Handrails shall be <br /> installed in accordance with R330.10.1. <br /> R330.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser <br /> to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4 <br /> R330.11 Shower stalls.Where provided to meet the requirements for bathing facilities,the minimum size of shower stalls for an <br /> adult family home shall be 30 inches deep by 48 inches long. <br /> [Statutory Authority:RCW 19.27.031 and chapters 19.27 and 34.05 RCW.13-04-068,§51-51-0325,filed 2/1/13,effective 7/MI Statutory <br /> Authority:Chapter 19.27 RCW. 10-18-036,§51-51-0325,filed 8/25/10,effective 9/25110.Statutory Authority:RCW 19,27.190,19.27.020,and <br /> chapters 19.27 and 34,05 RCW.09-04-023,§51-51-0325,filed 1127109,effective 7/1I10.Statutory Authority:RCW 79.27.074,i9.27 020,and <br /> chapters 19.27 and 34.05 RCW.07-01-090,§51-51-0325,filed 12119/06.effective 7/1/07.Statutory Authority:RCW 19.27.031 and 19.27.074.04- <br /> 01-109,§51-51-0325,fled 12/17103,effective 7/1/04.1[Statutory Authority:RCW 19,27.031 and 19,27.074.WSR 20-03- 223,§51-51-0330,filed <br /> 116120,effective 7/1/20.1 <br /> E <br /> E <br /> i <br /> I <br /> Implementation Date: 2021 February 01 <br /> Updated:2021 February <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.