Laserfiche WebLink
5FA Design Group, LLC <br />STRUCTURAL I CIVIL i LAND USE PLANNING <br />Bankston Residence U <br />SUBJECT <br />SafeBase-LD (Light D <br />Capacity of 3/4" 0 GR_ B_7 (125ksi) Threaded Rod i <br />�=11 <br />D = 0.750 in <br />Ft = 125 ksi <br />At = 0.344 in' <br />Capacity = 42.960 kips _ <br />0 Block Shear at 1/4" Plate 10 <br />TBs= 0.3(58)(1/4)(4.625)+0.5(58)(1/4)(1) <br />= 27.369 kips <br />Capacity of Weld 02 <br />E70 Electrodes = 70 ksi <br />Size of Fillet = 0.188 in <br />Length of Weld = 6.000 in <br />Capacity of Per Inch of Fillet = 2.784 kli <br />Capacity of Fillet = 16.705 kips <br />Capacity of 3/8' Plate Os <br />At = 1.125 in <br />Ft = 21.600 ksi <br />T = 24.300 kips <br />I = 0.844 in <br />A = 1.125 in <br />r = 0.866 in <br />k= 1.00 <br />I = 7.387 in <br />kl/r = 9.0 <br />Fa = 20.350 ksi <br />S = 3.410 in <br />Fb = 27.000 ksi <br />RmAx = 30.857 kips <br />Fv = 14.400 ksi <br />PROJECT NO. SHEET NO. <br />MFR23-236 <br />DATE <br />3/1 /2024 <br />10/2'. <br />r <br />1'-2" <br />� <br />VALLOW = 10.800 kips .4 Limiting System Factor <br />Results i <br />Capacity of System (2 Sides)=10.800(2)=21.600kips (Bracket Only) <br />