Laserfiche WebLink
�Tulie"Outpuf— --- ----------------a-------------__— _—��_ <br />kl/r = <br />13.04 Slenderness OK <br />Cc = <br />116.75 <br />F'e = <br />877.41 ksi <br />Fa = <br />24.43 ksi <br />fa = <br />1.77 ksi <br />Fb = <br />27.72 ksi <br />fb = <br />1.64 ksi <br />Cm = <br />1.00 <br />fa/Fa = <br />0.07 Eq 1-11-3 may be used <br />Eq H1-1 <br />NA <br />Eq H1-2 <br />NA <br />Eq H1-3 <br />0.13 <br />Pier OK <br />Threaded Rod Properties <br />__ _ _— <br />_�- <br />Threaded Rod Dia. = <br />1.250 in <br />k = <br />1.00 <br />r = <br />0.313 in <br />A = <br />1.227 in' <br />c = <br />0.625 in <br />S = <br />0.192 in <br />1 = <br />0.120 in <br />E = <br />29000 ksi <br />Fy = <br />70 ksi <br />QThreaded Rod Output <br />i <br />kl/r = <br />9.60 <br />Slenderness OK <br />Cc = <br />90.43 <br />F'e = <br />1619.74 ksi <br />Fa = <br />40.79 ksi <br />fa = <br />2.22 ksi <br />Fb = <br />46.20 ksi <br />fb = <br />14.19 ksi <br />Cm = <br />1.00 <br />fa/Fa = <br />0.05 <br />Eq H1-3 may be used <br />Eq H1-1 <br />NA <br />Eq H1-2 <br />NA <br />Eq H1-3 <br />0.36 <br />Tube OK <br />JBearing,Capacity of Lightfoot Footing <br />Footing Length = 21 in <br />Footing Width = 21 in <br />Soil Bearing Capacity = 1500 psf <br />Capacity = 3.375 kips OK <br />MAX LOAD TO SMART JACK = 2721LB <br />3.5 IN SQUARE TUBE WITH 11 GA (0.1196 IN) THICK WALL AND MAX HEIGHT OF 1.5FT <br />1.25 IN DIAMETER SOLID THREADED ROD WITH MAX HEIGHT OF 3 IN <br />21 IN SQ BASE WITH 18 IN SQ POLY FILL <br />EMBED THREADED ROD A MINIMUM OF 3/4 IN INTO CONFINING RING AND THREADED INSERT <br />