My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5900 36TH AVE W 2025-01-06
>
Address Records
>
36TH AVE W
>
5900
>
5900 36TH AVE W 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 3:28:40 PM
Creation date
12/18/2024 2:51:38 PM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
5900
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1780
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MSEW--Mechanically Stabilized Earth Walls Soundview Business Center <br /> Present Date/Time Thu Feb 09 14:25:34 2017 CAUsers\henry wright0ocumentsIMSEW HE Tiered,BEN <br /> 1- <br /> SOIL DATA <br /> REINFORCED SOIL <br /> Unit weight, 7 125.0 lb/ft 3 <br /> Design value of internal angle of friction, 32.00 <br /> RETAINED SOIL <br /> Unit weight, 7 125.0 lb/ft <br /> Design value of internal angle of friction, 32.00 <br /> FOUNDATION SOIL(Considered as an equivalent uniform soil) <br /> Equivalent unit weight, y equiv. 125.0 lb/ft <br /> Equivalent internal angle of friction, �equiv 32.00 <br /> Equivalent cohesion, C equiv. 0.0 lb/ft 2 <br /> Water table does not affect bearing capacity <br /> LATERAL EARTH PRESSURE COEFFICIENTS <br /> Ka(internal stability)=0.3073 (if batter is less than 10',Ka is calculated from eq. 15. Otherwise,eq.38 is utilized) <br /> Inclination of internal slip plane, W=6 1.00' (see Fig.28 in DEMO 82). <br /> Ka(external stability)=0.3073 (if batter is less than 10',Ka is calculated from eq. 16. Otherwise,eq. 17 is utilized) <br /> BEARING CAPACITY <br /> Bearing capacity coefficients(calculated by MSEW): Nc=35.49 N y=30.21 <br /> SEISMICITY <br /> Maximum ground acceleration coefficient,A=0.300 <br /> Design acceleration coefficient in Internal Stability: Kh=Am=0.345 <br /> Design acceleration coefficient in External Stability: Kh—d=0.165 => Kh=Am=0.212 <br /> (Kh in External Stability is based on allowable displacement, d=25 mm.using AASHTO 2002 equation) <br /> Kae(Kh>0)=0.4504 Kae(Kh=0) =0.3073 A Kae=0.1432 <br /> Seismic soil-geogrid friction coefficient,F*is 80.0%of its specified static value. <br /> Soundview Business Center Page 2 of 5 <br /> Copyright(0 1998-2011 ADAMA Engineering,Inc. License number MLNL-301109 <br />
The URL can be used to link to this page
Your browser does not support the video tag.