MSEW--Mechanically Stabilized Earth Walls Soundview Technology Center
<br /> Present Datelrime: Tue Dec 13 14:07:51 2016 C:\Users\chase halsen\Desktop\Chase-Desktop Copies\Wall Designs\40t 1 05\50 67 Foot BEN
<br /> ..,,..w v. .?.wtv_ ,e,.,..,...„u,.._, ,wu,_..ose.x.....,.nu:.wv.,,.,o,�uw•,,.....w.iuw w.�.,.naL:.wv....,o.,scw v,..,o,onv,,,.bro,iu,vv.m.roascw v,.,A,o.ucw v....,uusEwv.W.,..wu.,....,w,.u,1.-,�o,w.....,.wv,�..... .........
<br /> INPUT DATA: Geogrids
<br /> (Analysis)
<br /> D A T A Geogrid Geogrid Geogrid Geogrid Geogrid
<br /> tune#1 tvae#2 type#3 tvne#4 tvne#5
<br /> Tult [Ib/ftl 4700.0 5900.0 9500.0 13705.0 20559.0
<br /> Durability reduction factor,RFd 1.10 1.10 1.10 1.10 1.10
<br /> Installation-damage reduction factor,RFid 1.10 1.10 1.10 1.10 1.05
<br /> Creep reduction factor,RFc 1.58 1.58 1.58 1.58 1.58
<br /> Fs-overall for strength N/A N/A N/A N/A N/A
<br /> Coverage ratio,Rc 1.000 1.000 1.000 1.000 1.000
<br /> Friction angle along geogrid-soil interface, p 24.00 24.00 24.00 24.00 21.33
<br /> Pullout resistance factor,F* 0.80•tarf 0.80•tanp 0.80-tanp 0.80•tanp 0.80•ta4
<br /> Scale-effect correction factor, a 0.8 0.8 0.8 0.8 0.8
<br /> Note:Z for calculating K/Ka and F*is measured from roadway surface(FHWA-NHI-10-024).
<br /> Variation of Lateral Earth Pressure Coefficient With Depth
<br /> Z K/Ka K/Ka
<br /> 0 0.0 1.0 2.0 3.0
<br /> 0 ft 1.00
<br /> 3.3 ft 1.00 Z Ift]6.6
<br /> 6.6 ft 1.00
<br /> 9.8 ft 1.00 9.8
<br /> 13.1 ft 1.00
<br /> 16.4 ft 1.00 16.4
<br /> 19.7 ft 1.00
<br /> 26.2
<br /> 32.8
<br /> Soundview Technology Center Page 3 of 5
<br /> Copyright U 1998-201 l ADAMA Engineering,Inc. License number MLNL-301109
<br /> ....r,W.a.�..Y4.�r.:,.w.,r.1W.. _...... ... �. .....-. ._.uMu,��.u1�N,..r•ems,.nalem.x�...ra11r.,...i,ri,r4foa.,�...lem.�umP•....HeR1 M...w1�n,rter.l l�..sewH.e...xw.,.....1.
<br />
|