McGraw-Ediso� GalleonGALN
<br /> Ordering Information
<br /> SAMPLE NUMBER: GALN-SA4C-740-U-T4FT-GM
<br /> Product Family 1.2 Light Engine Color Distribution Mounting Finish
<br /> Configuration Drive Current Temperature
<br /> GALN=Galleon II SA1=1 Square A=600mA 722=70CRI,2200K U=120-277V T2=Type II [Blank]=Standard Pole Mount Arm AP=Grey
<br /> BAA-GALN=Galleon II SA2=2 Squares B=800mA 727=70CRI,2700K H=347V-48OV7,30 T2R=Type II Roadway QM=Standard Pole Mount Arm BZ=Bronze
<br /> Buy American Act SA3=3 Squares C=1000mA 730=70CRI,3000K 1=120V T3=Type III with Quick Mount Adaptor BK=Black
<br /> Compliant 27 SA4=4 Squares D=1200mA 4,17 735=70CRI,3500K 2=208V T3R=Type III Roadway PA=Pole Mount,Adjustable DP=Dark Platinum
<br /> TAA-GALN=Galleon II SAS=5 Squares 740=70CRI,4000K 3=240V T4FT=Type IV Forward Throw SP=Slipfitter,Adjustable GM=Graphite Metallic
<br /> Trade Agreements Act SA6=6 Squares 750=70CRI,5000K 4=277V
<br /> g , T4W=Type IV Wide MA=Mast Arm,Fixed WH=White
<br /> Compliant 27 SA7=7 Squares 760=70CRI,6000K 8=480V ao 5NQ=Type V Narrow WM=Wall Mount,Fixed RALXX=Custom Color
<br /> SA8=8 Squares 827=80CRI,2700K 9=347V
<br /> SA9=9 Squares 830=80CRI,3000K DV=277V-480V DuraVolt 5MQ=Type V Square Medium WA=Wall Mount,Adjustable
<br /> AMB=Amber,590nm's,,, Drivers?9031 5WQ=TypeV Square Wide UP=Upswept Arm
<br /> SL2=Type II w/Spill Control
<br /> SL3=Type III w/Spill Control
<br /> SL4=Type IV w/Spill Control
<br /> SLL=90"Spill Light Eliminator Left
<br /> SLR=90"Spill Light Eliminator Right
<br /> RW=Rectangular Wide Type I
<br /> AFL=Automotive Frontline
<br /> 0, r, (Order
<br /> DIM=External 0-10V Dimming Leads'' BPC=Button Type Photocontrol' OA/RA1016=NEMA Photocontrol Multi-Tap-105-285V
<br /> F=Single Fuse(120,277 or 347V Specify Voltage) PR=NEMA 3-PIN Photocontrol Receptacle OA/RA1027=NEMA Photocontrol-480V
<br /> FF=Double Fuse(208,240 or 480V Specify Voltage) PR7=NEMA TPIN Photocontrol Receptacle 11 OA/RA1201=NEMA Photocontrol-347V
<br /> 20K=2OkV UL 1449 fused surge protective device 10 FADC=Field Adjustable Dimming Controller 32 OA/RA1013=Photocontrol Shorting Cap
<br /> 2L=Two Circuits" SPB2=Dimming Motion Sensor,9'-20'mounting R1 OA/RA1014=120V Photocontrol
<br /> HA=50°C High Ambient SPB4=Dimming Motion Sensor,21'-40'mounting E4 MA1252=10kV Surge Module Replacement
<br /> HSS=Installed House Side Shield 1° SPB2/X=Dimming Motion Sensor,limited square count,9'-20'mounting 24 MA1036-XX=Single Tenon Adapter for 2-3/8"O.D.Tenon
<br /> GRSBK=Glare Reducing Shield,Black" SPB4/X=Dimming Motion Sensor,limited square count,21'-40'mounting 2° MA1037-XX=2@180"Tenon Adapter for 2-3/8"O.D.Tenon
<br /> GRSWH=Glare Reducing Shield,White" ZW=WaveLinx Module and 4-PIN Receptacle 19 MA1197-XX=3@120"Tenon Adapter for 2-3/8"O.D.Tenon
<br /> LCF=Light Square Trim Painted to Match Housing16 ZD=WaveLinx Module with DALI driver and 4-PIN Receptacle" MA1188-XX=4@90"Tenon Adapter for 2-3/8"O.D.Tenon
<br /> TH=Tool-less Door Hardware 3 ZW-SWPD4XX=WaveLinx Sensor Only,7-15ft 11,12,13 MA1189-XX=2@90"Tenon Adapter for 2-3/8"O.D.Tenon
<br /> CC=Coastal Construction finish 3 ZW-SWPD5XX=WaveLinx Sensor Only,15-40ft",12,19 MA1190-XX=3@90"Tenon Adapter for 2-3/8"O.D.Tenon
<br /> L90=Optics Rotated 90"Left ZW-WOBXX=WaveLinx Sensor with Bluetooth,7-15ft 11,12•13 MA1191-XX=2@120°Tenon Adapter for 2-3/8"O.D.Tenon
<br /> R90=Optics Rotated 90"Right ZW-WOFXX=WaveLinx Sensor with Bluetooth,15-40ft 11,11,11 MA1038-XX=Single Tenon Adapter for 3-1/2"O.D.Tenon
<br /> AHD145=After Hours Dim,5 Hours R2 ZD-SWP04XX=WaveLinx Sensor Only,7-15ft",1R,19 MA1039-XX=2@180°Tenon Adapter for 3-1/2"O.D.Tenon
<br /> AHD245=After Hours Dim,6 Hours R2 ZD-SWP05XX=WaveLinx Sensor Only,15-40ft19,12," MA1192-XX=3@120°Tenon Adapter for 3-1/2"O.D.Tenon
<br /> AHD255=After Hours Dim,7 Hours R2 ZD-WOBXX=WaveLinx Sensor with Bluetooth,7-15ft 19,12•13 MA1193-XX=4@90"Tenon Adapter for 3-1/2"O.D.Tenon
<br /> AHD355=After Hours Dim,8 Hours R2 ZD-WOFXX=WaveLinx Sensor with Bluetooth,15-40ft 11,12,19 MA1194-XX=2@90"Tenon Adapter for 3-1/2"O.D.Tenon
<br /> DALI=DALI Drivers DIM70-MS/DIM-L20=Synapse Occupancy Sensor(9'-20'Mounting)19 MA1195-XX=3@90"Tenon Adapter for 3-1/2"O.D.Tenon
<br /> DIM10-MS/DIM-L40=Synapse Occupancy Sensor(21'-40'Mounting)19 SRA238=Adapter kit for mounting to 2-3/8"O.D.Tenon
<br /> LS/HSS=Field Installed House Side Shield'"
<br /> LS/GRSBK=Glare Reducing Shield,Black9.29
<br /> LS/GRSWH=Glare Reducing Shield,White9.29
<br /> LS/PFS=Perimeter Shield,Black"
<br /> WOLC-7P-10A=WaveLinx Outdoor Control Module 119
<br /> WOA-XX=WaveLinx Wireless Sensor,T-1 5'Mounting Height"1914,'9
<br /> WOE-XX=WaveLinx Wireless Sensor,15'-40'Mounting Height 121314"
<br /> NOTES:
<br /> 1.Customer is responsible for engineering analysis to confirm pole and fixture compatibility for all applications.Refer to our 17.Not available with HA option.
<br /> white paper WP513001 EN for additional support information. 18.Not for use with 5NQ,5MQ,5WQ or RW optics.A black trim plate is used when HISS is selected.
<br /> 2.DesignLights Consortium®Qualified.Refer to www.designlights.org Qualified Products List under Family Models for details. 19.Cannot be used with other control options.
<br /> 3.Coastal construction finish salt spray tested to over 5,000-hours per ASTM B117,with a scribe rating of 9 per ASTM D1654. 20.Low voltage control lead brought out 1 B"outside fixture.Not available with DALI or integrated controls options
<br /> Not available with TH option. 21.Not available if any SPB,LWR,or WaveLinx sensor is selected.Motion sensor has an integral photocell.
<br /> 4.Drive current 1200mA not available with color temperatures 722,727 or 830 when either HA or HSS options are selected. 22.Requires the use of BPC photocontrol or the PR7 or PR photocontrol receptacle with photocontrol accessory.
<br /> 5.TH option not 3G rated.Not available with Coastal Construction(CC)option. 23.Not for use with T4FT,T4W or SL4 optics.See IES files for details.
<br /> 6.Not available with voltage options H,8 or 9. 24.Sensor configuration mobile application required for configuration.See controls page for details.
<br /> 7.Requires the use of an internal step down transformer when combined with sensor options.Not available in combination with 25.Replace X with number of Light Squares controlled by the SPB,referencing the"SPB/X Availability Table"on the controls page.
<br /> the HA high ambient and sensor options at 1A. 26.Not available with HSS,GRSWH or GRSBK.
<br /> 8.Adjustable Slipfitter arm limited to vertical 3"tenon.For mounting to 2-3/8"O.D.tenons,order accessory SRA238. 27.Only product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933(BAA)or
<br /> 9.One required for each Light Square. Trade Agreements Act of 1979(TAA),respectively.Please refer to DOMESTIC PREFERENCES websile for more information.
<br /> 10.2L is not available with SPB at 347V or 480V Not available with WaveLinx or Enlighted sensors,or 20kV surge option. Components shipped separately may be separately analyzed under domestic preference requirements.
<br /> 11.Requires PR7. 28.For BAA or TAA requirements,Accessories sold separately will be separately analyzed under domestic preference requirements.
<br /> 12.Replace XX with sensor color(WH,BZ or BK.) Consult factory for further information.
<br /> 13.WAC Gateway required to enable field-configurability:Order WAC-PoE and WPOE-120(1 OV to PoE injector)power supply if 29.DuraVolt drivers feature added protection from power quality issues such as loss of neutral,transients and voltage Fluctuations.Visit
<br /> needed.WAC not required for LC Bluetooth sensors. www sian fycom/duravolt for more information.
<br /> 14.Requires ZW or ZD receptacle. 30.480V not to be used with ungrounded or impedance grounded systems.
<br /> 15.Narrow-band 590nm+/-5nm for wildlife and observatory use.Choose drive current A;supplied at 500mA drive current only. 31.Not available in 1 square configuration at 800mA or below.Not available with any control option except SPB.
<br /> Exact luminaire wattage available in IES files.Available with 5WQ,5MQ,SL2,SL3 and SL4 distributions.Can be used with HSS 32.Cannot be used with PR7 or other motion response control options.
<br /> option.
<br /> 16.Set of 4 pcs.One set required per Light Square.
<br /> umenSafe Integrated Network Security Camera Technology Options(Add as Suffix)
<br /> Product Family Camera Type Data
<br /> L=LumenSafe Technology r�11 D=Standard Dome Camera C=Cellular,No SIM R=Cellular,Rogers
<br /> lj H=Hi-Res Dome Camera A=Cellular,AT&T W=Wi-Fi Networking w/Omni-Directional Antenna
<br /> Z=Remote PTZ Camera V=Cellular,Verizon E=Ethernet Networking
<br /> me sore a=n��ev S=Cellular,Sprint
<br /> (jO CLOtOP EoR PS5000 2 EN p g e 2