My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5900 36TH AVE W 2025-01-06
>
Address Records
>
36TH AVE W
>
5900
>
5900 36TH AVE W 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 3:28:40 PM
Creation date
12/18/2024 2:51:38 PM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
5900
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1780
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\\nov-beI-file.pIb.corp\projects\wa shin gton\Everett\soundview\2drowings\EVSV-131J.dwg Nov 17, 2023 - 2:58pm <br /> NE AND SE 1/4, NE 1/4, SECTION 03, TOWNSHIP 28 NORTH, RANGE 4 EAST, W.M. NOTES <br /> _ SEE SHEET C-3.5 FOR CONTINUATION _ <br /> 1. OFF-SITE WATER IMPROVEMENTS c <br /> SHALL BE IN ACCORDANCE WITH 0. <br /> 77N:348667.74 16 COE STANDARD DWG. CONSTRUCT <br /> E:1285241.50 NEW 8" WM 4' (OUT TO OUT) U <br /> I COE 15' WATER LINE EASEMENT W <br /> I I � � FROM EXISTING 6" WM. � I <br /> 15.5' CONTRACTOR SHALL REMOVE Q <br /> 3 I� AND REPLACE ALL REMOVED C <br /> H <br /> MATERIALS IN-KIND. W 2. CONTRACTOR TO VERIFY NEW 0 15 30 60 •g <br /> WATER MAIN SEPARATION FROM SCALE: 1 INCH=30 FEET <br /> B N <br /> UILDI G A M THE EXISTING SEWER MAIN IS <br /> I I O � 1 TEN FEET MINIMUM. <br /> FFE=346 9$ LF 6" DI t <br /> 663 LF 12" CPEP TIGHTLINE (A SOUTH) I "' O <br /> CONNECT TO ROOF DRAINS I \ LEGEND <br /> ADD SDCO AT CORNERS G -W- WATER MAIN PIPE <br /> RIM TO GRADE <br /> ^? / m _ DOMESTIC WATER PIPE <br /> Po/i Z B WATER METER <br /> I 612 LF 12" CRIER TIGHTLINE A EAST <br /> WATER TEE <br /> CONNECT TO ROOF DRAINS----] GATE VALVE <br /> ADD SDCO AT CORNERS JR FIRE HYDRANT <br /> RIM TO GRADE O N:348472.01 I FIRE DEPARTMENT CONNECTION <br /> E:1285171.13 ^ 90'BEND pp <br /> I 7 LF 6" DI 45°BEND m ^ Z <br /> k -A, 22.5° BEND 0 <br /> 1 may/ '� 11.25°BEND o <br /> w <br /> C/ _7 <br /> ------ N:348472.18 " DCDA- ------------------ E:1285164.15 �342DCVA <br /> � PRESSURE REDUCING VALVE <br /> 77 LF 8" DI ^IX I 370 LF 8" DI <br /> I I / 77 LF 8" DI <br /> COE 15' WATER LINE EASEMENT - <br /> ;! <br /> M O N:348464.80 <br /> 517 LF 8 DI I "� N:348388.16 Q <br /> 16 15 E:1285464.80 p <br /> 03 <br /> ---------------------------- E1285234.50 <br /> 21------------------------------------------------- <br /> w <br /> O 7 LF 6' DI W <br /> _ ---------------------- <br /> 1 N:3483454�� <br /> P9 <br /> ___ � I O� W E:1285556 x <br /> 4 N:348386.31 N:348369.77 -------- N:348394.91 14 <br /> j OE:1285058.77 - E:1285058.33 O O <br /> 5 E:1285162.05 I 15 N:348372.790.81 49 W <br /> E:1285490.81 <F <br /> z 357 }58 360 361 N:348383.81 8.. <br /> z 359 362 365 E:1285150.33REc1S7E4Q'�`1{iFe <br /> 363 364 }66 367 368 .o I SSIONAL @1ao <br /> O / 369 373 I I 8. <br /> 255344 <br /> E:18U 37 375 376 <br /> /+N <br /> 377 b7a RECORD DRAWINGS <br /> 379 380 0 1 22 LF 8" DI <br /> 381 382 <br /> / / / 383 384 / 1 I <br /> ti ,� a h 3e5 3s6 / 1,�, 1 CUT AND CAP <br /> O M h M ,� l � � 387 �I <br /> EXISTING WATER MAIN <br /> ,`O ^ / / / / / 389 389 390 391 3i3 1 I TO BE DECOMISSIONED J p 0 E <br /> 392 393 1 11 I (BY COE) <br /> M <br /> /U 11 WATER SCHEDULE v x <br /> � > <br /> 39t CONNECT TO EXISTING WATER MAIN 10 1-2" METER PER CITY OF EVERETT STD. F v a c <br /> W 39a 392 m <br /> 393 / I 1-8"x12" TEE (FLxMJ) DETAIL 502 <br /> W3gg ae h / O 1-8" GATE VALVE (FLxMJ) N <br /> 400 399 m I I 1-6" 90' BEND (MJ) C`J <br /> (= oa ao3 402 401 •'�� ��� I 11 I THRUST RESTRAINT PER COE STANDARDS 11 THRUST RESTRAINT PER COE STANDARDS �l <br /> ;5 1-8"x8" TEE (FL) 1-6" 45' BEND (MJ) <br /> LLi 11 O 2-8" GATE VALVE (FLxMJ) 2 THRUST RESTRAINT PER COE STANDARDS L� <br /> W Aga 1-8" ADAPTOR (FLxMJ) <br /> 1-8" 90' BEND (MJ) <br /> a(n COE 15' WATER 11 THRUST RESTRAINT PER COE STANDARDS 13 <br /> -N:348211.24 ao 1 THRUST RESTRAINT PER COE STANDARDS w o <br /> o� LINE EASEMENT O5 N:348210.88 t <br /> E:1284681.06�E:1284810.84 N:348182.96 8 7 LF 6" DI �ao3 1 I 1-8"x8" TEE (FL) 14 1-8" 45° BEND (MJ) <br /> �' 15.0' E:1284832.43 EN:348197.44 N:348191.04 1 O3 1-8" GATE VALVE (FLxMJ) O THRUST RESTRAINT PER COE STANDARDS 3 <br /> � E:1284948.79 COE 15' WAT LINE EASEMENT 14 N:348192.12 E:1285173.45 .ao2� 1 I THRUST RESTRAINT PER COE STANDARDS °''� d <br /> 4 <br /> L------ - <br /> ------- E:1285161.23 15 1 8 225° BEND (MJ) oy� > <br /> 0 7 LF 6' DI ------ ---- ------------------ - 8 LF 6" DI .ao3 1-8"x6" TEE (FLxMJ) O THRUST RESTRAINT PER COE STANDARDS o� a� d <br /> N =- <br /> ---- ------- - I O TH6' GATE VALVE (FLxMJ) 1-8" 11.25' BEND (MJ) 'm a <br /> - --------- - 9 LF -404-- RUST RESTRAINT PER COE STANDARDS 16 THRUST RESTRAINT PER COE STANDARDS <br /> -- W <br /> __ I I O 1-FIRE HYDRANT ASSEMBLY PER CITY 17 1-8" PLUG (MJ) W/ MARKER <br /> z 193 LF 8" DI 23 LF 8" DI - - -405 1 I I OF EVERETT STD. DETAIL 507 1-DEADMAN BLOCKING W SHACKLES <br /> 1 I O6 1- FIRE DEPARTMENT CONNECTION ASSEMBLY PRESSURE REDUCING VALVE <br /> >u -ao6- 1 I 18 PER CITY OF EVERETT STD DETAIL 521 <br /> N:348201.97 O N:348200.13 1 3 I 1-8"x8" TEE (FLxMJ) <br /> 7 CONNECT TO BUILDING. RHEA FOR DOMESTIC <br /> E:1284680.80 O N:348204.37 O 407__ Ip 1 O 1-8" GATE VALVE (FLxMJ) 19 SERVICE AND DCDA FOR FIRE SERVICE <br /> E:1284840.89 E:1284948.96 5 212 LF 8" DI O4 N:348167.57 6 I THRUST RESTRAINT PER COE STANDARDS O <br /> N:348185.57 E:1285167.57 <br /> 11.5 LF 8� DI 10 LOCATED INSIDE BUILDING. SEE MEP AND FIRE <br /> v, E:1284814.46 I 1 I 1-2" DCVA PER CITY OF EVERETT STD. <br /> � 19 -ao8 � PROTECTION PLANS FOR CONTINUATION. <br /> N:348204.41 N:348200.78 N:348191.53 g II 1 I 8O DETAIL 520 <br /> I 23 9 E:1284948.61 O 19 LF 8" DI ''1 1t9 I 1-IRRIGATION METER 1-8"x10" TEE (FLxMJ) <br /> E:1284669.59 0 E:3 8 200.7 40 o 1 20 Z <br /> -ao9-- �" 1-10" GATE VALVE (FLxMJ) <br /> .o WALL-MOUNTED PIV N:348177.57 14 N:348178.53 I 1 I I 9 1-2" RESILIENT SEAT AND 2" OPERATING NUT. THRUST RESTRAINT PER COE STANDARDS Z <br /> N:348180.74 E:1284948.15 11 E:1285174.16 40-- 1 11 O 1-2" HEAVY DUTY GATE VALVE 21 ( ) uj 3 < <br /> 3 I E:1284818.34 11 1 1 I NOTE: USE MEGA LUG RESTRAINTS OR EQUAL 1-10" 90' BEND MJ �l <br /> THRUST RESTRAINT PER COE STANDARDS Iu > Z J <br /> ON ALL MECHANICAL JOINTS LARGER THAN 2 22 1-10" 45' BEND (MJ) w = IL <br /> °J -att 1 THRUST RESTRAINT PER COE STANDARDS � Q rn <br /> -o' I COE 15' WATER LINE EASEMENT 1 <br /> o I I THRUST RESTRAINT LENGTH SHALL BE PER 23 1-8- GATE VALVE (MJ) w <br /> 1 -412- TABLE 5A. (.0 w <br /> BUILDING B 55' <br /> 3 11 O <br /> 1 413-- 1 ENGINEERS CONSTRUCTION RECORD CERTIFICATION <br /> O W <br /> j I 1 1 THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE O) CC <br /> W Q <br /> WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED W 7Z <br /> FFE 4�4 202 LF 8" DI -ata I HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE M� W <br /> I I 1 NEW CONSTRUCTION SHOWN, BASED UPON OUR VISUAL W <br /> 3 I -415--- 1 1 I OBSERVATION, CONTRACTOR INSTALLATION NOTES AND <br /> FIELD MEASUREMENTS BY THE CONTRACTOR. THIS <br /> 1 DOCUMENT DOES NOT REPRESENT A DETAILED FIELD <br /> 416_ I 1 SURVEY. THESE PLANS ARE FINAL CORRECTED PLANS <br /> --------- <br /> --- I AND THE INFORMATION SHOWN ACCURATELY REFLECTS <br /> ---o --- __ EXISTING FIELD CONDITIONS AS OF THIS DATE: <br /> a <br /> a - -4zo -- I I I 1 I 11/01/2023. THE ENGINEER HEREBY CERTIFIES THAT, <br /> 7 LF 8" DI _ 1 BASED UPON THE METHODOLOGY DESCRIBED ABOVE, <br /> az3/ -a18 1 CONSTRUCTION SHOWN IS CONSISTENT WITH THE <br /> a LI 1 DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY <br /> / 423 -419- 1 REPRESENTS THE EXISTING CONDITIONS, PER Q <br /> �472 423 / O N:348007.80 CONTRACTOR PROVIDED RECORD INFORMATION. <br /> 1/ \ / 1 / E 1285169.43 Q 0 <br /> 4z1- A\ // 4$21 1 -420- �I NA V TIFI <br /> 1/ N:348007.18 C-3.3 <br /> ___DATE__�i1-___- Know what's below. <br /> ' 422 <br /> � � � � ��/� � � � � � � � � � � Ili 12�ir53 5 ,� -az,- � BY- --- - <br /> SEE SHEET C-3.1 FOR CONTINUATION Call before you di <br />
The URL can be used to link to this page
Your browser does not support the video tag.