My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5900 36TH AVE W 2025-01-06
>
Address Records
>
36TH AVE W
>
5900
>
5900 36TH AVE W 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 3:28:40 PM
Creation date
12/18/2024 2:51:38 PM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
5900
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1780
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\\nov—beI—file.pIb.corp\projects\wa shin gton\Everett\soundview\2drowings\EVSV-131J.dwg Nov 17, 2023 — 2:59pm <br /> NE AND SE 1/4, NE 1/4, SECTION 03, TOWNSHIP 28 NORTH, RANGE 4 EAST, W.M. <br /> ' o <br /> .a <br /> �J .W <br /> 0 <br /> WATER SCHEDULE o <br /> CONNECT TO EXISTING WATER MAIN 1-2" METER PER CITY OF EVERETT STD. I 0 15 30 60 •> <br /> O1-8"x12" TEE (FLxMJ) 10 DETAIL 502 <br /> 1-8" GATE VALVE (FLxMJ) 11-15" 90' BEND (MJ) <br /> O <br /> THRUST RESTRAINT PER COE STANDARDS 11 THRUST RESTRAINT PER COE STANDARDS SCALE: 1 INCH=30 FEET <br /> 1-8"x8" TEE (FL) 1-6" 45' BEND (MJ) I <br /> O 2-8" GATE VALVE (FLxMJ) 12 THRUST RESTRAINT PER COE STANDARDS <br /> 1-8" ADAPTOR (FLxMJ) 1-8" 90' BEND (MJ) <br /> THRUST RESTRAINT PER COE STANDARDS 13 THRUST RESTRAINT PER COE STANDARDS LEGEND <br /> 1-8"x8" TEE (FL) 1-8" 45' BEND (MJ) I —W— WATER MAIN PIPE <br /> O 1-8" GATE VALVE (FLxMJ) 14 THRUST RESTRAINT PER COE STANDARDS DOMESTIC WATER PIPE <br /> THRUST RESTRAINT PER COE STANDARDS 1-8" 225'BEND (MJ) e WATER METER <br /> 15 IT WATER TEE <br /> 1-8"x6" TEE (FLxMJ) THRUST RESTRAINT PER COE STANDARDS N GATE VALVE <br /> O4 1-6" GATE VALVE (FLxMJ) 16 1-8" 11.25' BEND (MJ) I ,LL FIRE HYDRANT Z <br /> THRUST RESTRAINT PER COE STANDARDS THRUST RESTRAINT PER COE STANDARDS � FIRE DEPARTMENT CONNECTION <br /> O1-FIRE HYDRANT ASSEMBLY PER CITY 17 1-8" PLUG (MJ) W/MARKER 4' 90' BEND <br /> OF EVERETT STD. DETAIL 507 1-DEADMAN BLOCKING W SHACKLES 45' BEND <br /> O6 1- FIRE DEPARTMENT CONNECTION ASSEMBLY 18 PRESSURE REDUCING VALVE -*1 22.5' BEND 0 ^ <br /> PER CITY OF EVERETT STD DETAIL 521 o0 <br /> 1-8"x8" TEE (FLxMJ) 'T' 11.25' BEND o <br /> O 1-8" GATE VALVE (FLxMJ) 19 CONNECT TO BUILDING. RPBA FOR DOMESTIC 0 DCDA d <br /> THRUST RESTRAINT PER COE STANDARDS SERVICE AND DCDA FOR FIRE SERVICE I o <br /> 1-2" DCVA PER CITY OF EVERETT STD. LOCATED INSIDE BUILDING. SEE MEP AND FIRE 0 DCVA <br /> PROTECTION PLANS FOR O CONTINUATION.8 DETAIL 520 ® PRESSURE REDUCING VALVE <br /> 1-IRRIGATION METER 20 1-8%10" TEE (FLxMJ) <br /> O GATE VALVE (FLxMJ)THRUST <br /> I i <br /> y 1-2" RESILIENT SEAT AND 2" OPERATING NUT. THRUST RESTRAINT PER COE STANDARDS <br /> 1-2" HEAVY DUTY GATE VALVE 21 1-10" 90' BEND (MJ) <br /> c� c� <br /> NOTE: USE MEGA LUG RESTRAINTS OR EQUA THRUST RESTRAINT PER COE STANDARDS <br /> L y y <br /> ON ALL MECHANICAL JOINTS LARGER THAN 2". 22 1-10" 45' BEND (MJ) I Y € Y <br /> THRUST RESTRAINT PER COE STANDARDS m <br /> THRUST RESTRAINT LENGTH SHALL BE PER 23 1-8- GATE VALVE(MJ) 0 V <br /> TABLE 5A. <br /> I <br /> IO ��ILLIq,y <br /> I� P <br /> D <br /> z 41071 e <br /> fop RA'CISTE4Q'O6 <br /> I ffSSIONAL <br /> O 0 RECORD DRAWINGS <br /> LL <br /> J o E <br /> I C7 1 rn ci <br /> V o <br /> N <br /> N:348837.58 5 N:3488O6.42 Ili <br /> 30� E:1284161.65 1 q N:348834.47 E:1284562.44 9 N348824.84IF <br /> IJJ <br /> E: / ---- ------ E:1284284.26 E:1284635.24 <br /> _-- <br /> u�'-, 3oe 33 LF 8" DI // 122 LF 8" DI --- ------ _ <br /> cV / / W yy -- W- 2- LF 8" DI rt5 ro 3 <br /> ————— <br /> --- l0 <br /> /---------------- W W <br /> ——— ------- W 7� LF 8' DI <br /> ---------------- <br /> 1 / / ---------- <br /> -20 LF DI 1 -- <br /> � ---W-7j- odd <br /> N:348826.79 a <br /> E 12FF-6" DI 91 O <br /> z 1 1 L <br /> 21 LF 6" 4- <br /> — <br /> 3�5 I N:348815.19 14 N:348813.97 <br /> - E:1284138.O3 O5 <br /> E:1284283.49 COE 15' WATER LINE EASEMENT <br /> N:12348798.042 .11 N1284634.73 <br /> E:1284283.11 10 ENGINEERS CONSTRUCTION RECORD CERTIFICATION <br /> > 1I E:1284634.73 <br /> 1 314 I I 8 O THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE N:348795.32 WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED Z <br /> I ,fie E:1284634.5O HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE O z <br /> o W NEW CONSTRUCTION SHOWN, BASED UPON OUR VISUAL <br /> 89 LF 8" DI I OBSERVATION, CONTRACTOR INSTALLATION NOTES AND W Z <br /> j o FIELD MEASUREMENTS BY THE CONTRACTOR. THIS Ir W - J <br /> 3 �ti N:348698.55 4 DOCUMENT DOES NOT REPRESENT A DETAILED FIELD W Q 2 <br /> E:1284134.83 O SURVEY. THESE PLANS ARE FINAL CORRECTED PLANS rn <br /> 12.0 = Q <br /> AND THE INFORMATION SHOWN ACCURATELY REFLECTS <br /> 0 <br /> 1 elcr <br /> N:348698.21 O EXISTING FIELD CONDITIONS AS OF THIS DATE: W <br /> E:1284147.33 11/01/2023. THE ENGINEER HEREBY CERTIFIES THAT, O co � WW <br /> ti BASED UPON THE METHODOLOGY DESCRIBED ABOVE, p r <br /> CONSTRUCTION SHOWN IS CONSISTENT WITH THE O <br /> � <br /> DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY 7Z <br /> 0 1 REPRESENTS THE EXISTING CONDITIONS, PER 6 W <br /> 6 BUILDING A NOVTRACTOR(PROVIDED RECORD INFORMATION. W <br /> 13 LF " DI <br /> 99 LE 8" DI FFE=346 <br /> BY I I _ — _DATE <br /> _ 11/�/`�•9— — _ <br /> I <br /> 1 I i <br /> I 0 <br /> 1 9A�COE 15' WATER LINE EASEMENT <br /> Know what's below. <br /> SEE SHEET C-3.4 FOR CONTINUATION Call before you di <br />
The URL can be used to link to this page
Your browser does not support the video tag.