My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST 1 KAISER PERMANENTE 2025-01-24
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
2930 MAPLE ST 1 KAISER PERMANENTE 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 3:43:10 PM
Creation date
12/31/2024 1:14:31 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Unit
1
Tenant Name
KAISER PERMANENTE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOL SCHEDULE ������ PAI MANEnrrE <br /> GENERAL LEGEND CONTROL SYSTEM LEGEND PIPE SYSTEMS LEGEND ABBREVIATIONS Project <br /> Kaiser Permanente Everett <br /> MATCH LINE t %X { 2-WAY MODULATING CONTROL VALVE,XX =SPECIAL f--s—t ARROW INDICATES DIRECTION OF FLOW ABV ABOVE OD OUTSIDE DIMENSION Specialty Center <br /> DESIGNATION(EG:PI=PRESSURE INDEPENDENT) UP AD ACCESS DOOR P y <br /> OUTSIDE STEM AND <br /> �(X 2-WAY 2-POSITION CONTROL VALVE,XX =SPECIAL ON SLOPE PIPE UP OR DOWN(DN)AS NOTED AFF ABOVE FINISHED FLOOR OS&Y CV YOKE GATE VALVE <br /> { ON 2930 MAPLE STREET <br /> 2 SECTION SECTION NUMBER t DESIGNATION(EG:BF=BUTTERFLY VALVE) �� ALT ALTITUDE P PUMP EVERETT,WA 98201 <br /> M3.1 DESIGNATION DRAWING NUMBER X 3-WAY MODULATING CONTROL VALVE,XX =SPECIALS APPROX APPROXIMATE PG PIPE GUIDE <br /> ems( TOP PIPE CONNECTION <br /> ' ^ DESIGNATION(EG:PI=PRESSURE INDEPENDENT) ARCH ARCHITECTURAL PH PHASE(ELECTRICAL) Prepared for <br /> 3-WAY 2-POSITION CONTROL VALVE,XX =SPECIAL 0----4 ELBOW TURNED UP AVC AVERAGE POC POINT OF CONNECTION KAISER FOUNDATION <br /> e DETAIL DETAIL NUMBER DESIGNATION(EG:BF=BUTTERFLY VALVE) C� ELBOW TURNED DOWN BG BELOW GRADE PRESS PRESSURE HEALTH PLAN, INC. <br /> DESIGNATION DRAWING NUMBER <br /> M2.1 CP �� BOP BOTTOM OF PIPE SPEC SPECIFICATION <br /> 2-WAY MODULATING CHARACTERIZED PORT BALL VALVE ,X BOTTOM PIPE CONNECTION NATIONAL FACILITIES SERVICES <br /> G. CENTERLINE SO.FT. SQUARE FEET <br /> HV EQUIPMENT EQUIPMENT TYPE f--�—i PUMP(FOR DIAGRAMMATIC) POST OFFICE BOX 12916 <br /> 1-1 DESIGNATION EQUIPMENT NUMBER t SOLENOID VALVE PIPING FLEXIBLE CONNECTION <br /> CMPR COMPRESSOR SS STAINLESS STEEL OAKLAND,CA 94604 <br /> { i--�—{ <br /> CONN CONNECTION,CONNECT STD STANDARD <br /> EQUIPMENT DESIGNATION REQUIRING <br /> ELECTRICAL CONNECTION(FUR-EQUIPMENT-NO) TAG BAS CONTRACTOR PROVIDED DCC POINT AND HARDWARE GATE VALVE CONT CONTINUATION SYM SYMBOL <br /> 1--04 —4 GLOBE VALVE DOC DIRECT DIGITAL CONTROL SYS SYSTEM <br /> EQUIPMENT DESIGNATION NOT REQUIRING DEG.F DEGREES FAHRENHEIT TOP TOP OF PIPE <br /> 1-HVC-1 ELECTRICAL CONNECTION(FUR-EQUIPMENT-NO) TAG CONTROL DEVICE PROVIDED BY ELECTRICAL CONTRACTOR i f�j {, CHECK VALVE <br /> BUT INTERFACED TO DDC SYSTEM BY BAS CONTRACTOR DIA DIAMETER TOR TOP OF RACK <br /> DEVICE BAS CONTRACTOR INTERFACE TO EQUIPMENT i fZ! 1 STOP CHECK VALVE <br /> AIR OUTLET/ DN DOWN TOT TOTAL <br /> 5 INLET DEVICE SD-1 12X12--FACE SIZE OPTIONAL TAG MANUFACTURER'S HARDWARE. HARD-WIRED UNLESS � LUBRICATED PLUG VALVE <br /> 55050 DESIGNATION 550 (IF NOT GIVEN REFER) NOTED OTHERWISE DWG DRAWING TYP TYPICAL <br /> TO SCHEDULE) <br /> AIRFLOW CFM) IQI {, CALIBRATED FLOW BALANCE VALVE (E) EXISTING UON UNLESS OTHERWISE NOTED <br /> ( TAG LOCAL CONTROL POINT(NO BAS INTERFACE) t <br /> FLOW LIMITING VALVE EFF EFFICIENCY V VOLT <br /> POINT OF CONNECTION,NEW WORK TO EXISTING WORK rj { BALL VALVE EXH EXHAUST VA VALVE <br /> GENERAL CONDITION EXP EXPANSION VERT VERTICAL <br /> HOSE END BALL VALVE WITH CAP AND CHAIN •F DEGREES FAHRENHEIT VFD VARIABLE FRED.DRIVE <br /> POINT OF DISCONNECTION BUTTERFLY VALVE <br /> 1. ALL WORK TO BE IN ACCORDANCE WITH REQUIREMENTS OF GOVERNING F FILTER VOL VOLUME <br /> LOCAL FIRE CODES AND BUILDING CODES. <br /> ANGLE VALVE (F) FUTURE W WATTS HellinUth,Obata&Kassabaum,Inc. <br /> 111 6 NEW WORK 2. VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS.NOTIFY ARCHITECT OF p FC FLEXIBLE CONNECTION W/o WITHOUT 1218 Third Avenue,Suite 1315 <br /> ANY DISCREPANCIES FOUND.VERIFY DIMENSIONS OF ALL i f7V { 2-WAY MODULATING CONTROL VALVE <br /> EXISTING WORK TO REMAIN FLA FULL LOAD AMPS W{ WEIGHT Seattle,WA 98101 USA <br /> OWNER-FURNISHED OPERATING EQUIPMENT TO ENSURE PROPER p <br /> L- — — -4 EXISTING WORK TO BE REMOVED COORDINATIONt+1 206 493 1771 f+1 206 493 1778 <br /> WITH CONSTRUCTION. i dEl b 2-WAY 2-POSITION CONTROL VALVE FUR FLOOR <br /> 3. SCHEDULE ALL WORK ACCESS AND STORAGE WITH THE FACILITY i i 3-WAY MODULATING CONTROL VALVE FT FEET a2019 <br /> uction s imene�wei n.00ero�9nt.,reeer„ea <br /> ADMINISTRATOR. 3-WAY 2-POSITION CONTROL VALVE GA GAGE OR GAUGE 1.Association with <br /> SYMBOL LEGEND 4. CONTRACTOR SHALL PROVIDE DUST COVERS AS REQUIRED TO CONTAIN GAL GALLON <br /> DUST AND DEBRIS WITHIN CONSTRUCTION AREA AND KEEP DIRT AND DUST RELIEF VALVE Mortenson <br /> FOF FUEL OIL FILL PIPING TO A MINIMUM. GPM GALLONS PER MINUTE General comanlor <br /> PRESSURE REDUCING VALVE(PRV) GPH GALLONS PER HOUR 10230 NE Points Drive,Suite 300 <br /> FOS FUEL OIL SUPPLY PIPING 5. ALL REMOVED ITEMS DEEMED TO HAVE VALUE BY THE OWNER SHALL BE p MANUAL AIR VENT Kirkland,WA 98033 <br /> DELIVERED TO A PLACE OF STORAGE AT THE SITE AS DIRECTED.ALL i Q {, HD HEAD <br /> FOR FUEL OIL RETURN PIPING OTHER ITEMS MUST BE DISPOSED OF OFF SITE IN A LEGAL MANNER. I PIPE GUIDE HGT HEIGHT <br /> ConXtech,Inc <br /> ----FOV---- FUEL OIL VENT PIPING 6. WHERE EXISTING CONSTRUCTION IS CUT,DAMAGED.OR REMODELED,PATCH I PIPE SLIDE HP HORSEPOWER St udural Fabricator <br /> WITH MATERIALS TO MATCH IN KIND,QUALITY AND PERFORMANCE. 6701 Koll Center Parkway,Suite 150 <br /> ---FOEV--- FUEL OIL EMERGENCY VENT PIPING PIPE EXPANSION JOINT HR HOUR(S) Pleasanton,CA 94566 <br /> 7. CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR SAFETY OF ALL HVAC HEATING,VENTILATING <br /> PERSONS ON OR ABOUT THE CONSTRUCTION SITE IN ACCORDANCE WITH CHANGE IN PIPE SIZE,CONCENTRIC REDUCER AND AIR CONDITIONING <br /> APPLICABLE LAWS AND CODES.GUARD ALL HAZARDS IN ACCORDANCE WITH KPFF Consulting Engineers <br /> THE SAFETY PROVISIONS OF THE LATEST MANUAL OF ACCIDENT UNLESS SPECIFIED DIFFERENTLY Civil+SWclual Engineering <br /> PREVENTION PUBLISHED BY THE ASSOCIATED GENERAL CONTRACTORS OF HZ HERTZ 1601 Fifth Avenue,Suite 1600 <br /> AMERICA. i--lipm ECCENTRIC REDUCER ID INSIDE DIMENSION Seattle,WA 98101 <br /> 8. CLEAN ALL EXPOSED SURFACES AND NEW EQUIPMENT AFTER COMPLETION. i UNION IN INCHES <br /> INV INVERT ELEVATION Mazzetti <br /> 9. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN I CAPPED PIPE MEP+FP Engineering <br /> EXISTING NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND MAX MAXIMUM 2013 4th Avenue,Suite 200 <br /> CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING MFG MANUFACTURER Seattle,WA 98121 <br /> BARS.MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE <br /> REINFORCEMENT AND THE DRILLED-IN ANCHOR AND/OR PIN. MIN MINIMUM <br /> (N) NEW Key Plan <br /> DRAWING INDEX N/A NOT APPLICABLE <br /> NC NORMALLY CLOSED <br /> INK NECK <br /> MEO.1 SYMBOLS,DRAWING INDEX,NOTES AND SCHEDULES NO NORMALLY OPEN OR NUMBER N <br /> MEIA LEVELS P1 AND P3 PARTIAL PLANS -MECHANICAL AND ELECTRICAL NITS NOT TO SCALE S <br /> ME2.1 LEVELS P4 AND P5 PARTIAL PLANS- MECHANICAL AND ELECTRICAL <br /> ME3.0 FUEL OIL PIPING,WIRING CONTROLS DIAGRAMS <br /> ME4.0 ELECTRICAL SPECIFICATIONS <br /> FUEL OIL DAY TANK <br /> MARK DAY TANK Professional Seals <br /> LOCATION P4 <br /> SERVES GENERATOR g$ ST <br /> CAPACITY GALLONS 400 <br /> TYPE DESCRIPTION DAY TANK <br /> TANK 3 DOUBLE WALL <br /> INNER TANK STEEL �serti °d Lq <br /> INNER THICKNESS 10 GA ONAL ti�G GNALG I'a <br /> OUTER TANK STEEL <br /> FUEL STORED 2 DIESEL <br /> PRESSURE ATMOSPHERIC No. Description Data <br /> LEAK DETECTION [11 YES PERMITSET 03/18/20 <br /> SHIPPING WEIGHT WEIGHT: LEIS 1,150 <br /> BASIS OF DESIGN MANUFACTURER CONTAINMENT SOL. <br /> MODEL GE <br /> N CUBE <br /> NOTES 1 12, 4, 5, 6, 7 <br /> NOTES: <br /> 1. PROVIDE: OMNTEC DEL 800011P, LEVEL AND LEAK DETECTION SYSTEM. <br /> 2. SEE SPEC FOR ADDITIONAL SPECIALIZED REQUIREMENTS. <br /> 3. INTERSTITIAL SPACE WITH LEAK DETECTION. <br /> 4. PROVIDE WITH CONNECTIONS FOR EXTERNAL FUEL POLISHING <br /> 5. UL-142 LISTED WITH 7 GAL. SPILLBOX <br /> 6. LEVEL PROBE: BELDEN 8761, LEAK SENSOR: BELDEN 9940. <br /> 7. SEE SHEET M3.0 FOR DETAILS <br /> KP Project N. CAP020407 <br /> HOK Project N. <br /> Sheet Title: <br /> SYMBOLS, DRAWING <br /> INDEX, NOTES, AND <br /> SCHEDULES <br /> 24 Sheet Number <br /> ME0 . 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.