Laserfiche WebLink
ELECTRICAL GENERAL NOTES: KAISER <br /> 1. THIS FACILITY IS INTENDED TO CONTINUE OPERATIONS ` / PERMANENTE•, <br /> DURING CONSTRUCTION.COORDINATE ALL WORK WITH <br /> OWNER TO MINIMIZE DISRUPTIONS. Project <br /> 2. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC.COORDINATE Kaiser Permanente Everett <br /> INSTALLATION WITH EXISTING CONDTIONS. Specialty Center <br /> 3. ALL DEVICES SHOWN ARE NEW UNLESS OTHERWISE <br /> INDICATED. 2930 MAPLE STREET <br /> 4. INSTALL PER MANUFACTURER'S REQUIREMENTS REFER EVERETT,WA 98201 <br /> TO EQUIPMENT SCHEDULE FOR MORE INFORMATION. <br /> Prepared for <br /> 5 WHERE POSSBLEXTOS CONCEAL,ED UCONTRACTOR SHALL IDENTIT IS NOTED,OR IT IS IFY KAISER FOUNDATION <br /> ROUTING IN FIELD AND OBTAIN ARCHITECT'S APPROVAL HEALTH PLAN, INC. <br /> OF ROUTING PRIOR TO ROUGH-IN. EXPOSED CONDUIT <br /> SHALL BE ROUTED TIGHT TO STRUCTURE. NATIONAL FACILITIES SERVICES <br /> 6. PROVIDE A DEDICATED NEUTRAL FOR EACH CIRCUIT. POST OFFICE BOX 12916 <br /> OAKLAND,CA 94604 <br /> 7. CIRCUIT BREAKERS ADDED TO EXISTING PANELS SHALL <br /> MATCH EXISTING BREAKERS TYPE, MANUFACTURER AND <br /> AIC RATING. UPDATE DIRECTORIES IN EXISTING PANELS <br /> TO REFLECT CHANGES BY THIS RENOVATION. <br /> ELECTRICAL KEY NOTES: <br /> O PROVIDE DEDICATED 120V/1PH/20A BRANCH CIRCUIT , <br /> CONNECTION TO TANK CONTROL PANEL FROM AVAILABLE <br /> SPARE BREAKER IN NEAREST 120/208V EMERGENCY <br /> PANEL. <br /> 1 2 3 4 5 6 7 8 9 10 1 12 13 14 15 <br /> Hellmuth,Obata&Kassabaum,Inc. <br /> 1218 Third Avenue,Suite 1315 <br /> Seattle,WA 98101 USA <br /> t+1 206 493 1771 f+1 206 493 1778 <br /> BRING ALL VENTS MIN <br /> 12"ABOVE ROOF ° <br /> DAY TANK CONTROL PANEL 20Association with anecwrii ProPero ngnt,reserves <br /> 99 In <br /> III <br /> (1)2-NORMAL VENT III <br /> (2)a"EMERGENCY VENT III O Mortenson <br /> General COM2Mor <br /> NEW 400 GALLON DAY TANK. III 10230 Points Drive,Suite 300 <br /> Kirkland, <br /> WA 98033 <br /> REFER TO SHEET M3.0 FOR <br /> VALVE,CONTROLS AND WIRING. <br /> ConXtech,lnc <br /> Shuclural Fabricator <br /> 6701 Koll Center Parkway,Suite 150 <br /> Pleasanton,CA 94566 <br /> HC H� HC HC AC HC HI HI HC HI HC HC HI HI KPFF PIF Consulting <br /> Engineering <br /> Engineers <br /> CIA <br /> 1601 Fifth Avenue,Suite 1600 <br /> Seattle,WA 98101 <br /> 2"FOF SLOPED TOWARD TANK <br /> 2"FOS/FOR TO GENERATOR. <br /> REFER TO DETAIL 1 ON M3.0 FOR SBOOP2 Mazzetti <br /> PIPING DIAGRAMS AND OPERATION. PARKA MEP+FPenng <br /> KFHP 2013 4th Avenue,Suite 200 <br /> Seattle,WA 98121 <br /> V Key Plan <br /> EXISTING GENERATOR <br /> 14 15 <br /> D N <br /> Li S <br /> C c c c c c c c c c c <br /> BOOPIA <br /> SEL I I I IqRAJ2 I <br /> Professional Seals <br /> SBOOE4 VESEL <br /> ELEVA <br /> �W Sr c c.sR <br /> 2"FOF DN 0 P4 <br /> SBOOE3 2"FOF FROM P spa oA <br /> SBOOEI T <br /> b / <br /> 0��G� Op�Glye <br /> SBOOLl <br /> VESEL <br /> BODS1 n No. Description Dale <br /> STAIR o 0 <br /> PERMITSET 03/18/20 <br /> SBOOPI <br /> PARKA <br /> KFHP <br /> 2"FOS SLOPED TOWAR <br /> B <br /> C C C <br /> 2"FOF UP/DN <br /> AFL <br /> 2"FOS ON <br /> KP Project N. CAP020407 <br /> LEVEL P5 PARTIAL FLOOR SDK Projec No: <br /> Sheet Title' <br /> PLAN - MECHANICAL AND LEVELS P4 AND P5 <br /> LEVEL P4 FLOOR PLAN - MECHANICAL AND ELECTRICAL 2 ELECTRICAL PARTIAL PLANS - <br /> M2.1 M2.1 MECHANICAL AND <br /> SCALE: 1/8"= 1'-0" <br /> ELECTRICAL <br /> 24 Sheet Number <br /> ME2 . 1 <br />