ELECTRICAL SYMBOL SCHEDULE
<br /> F\11/� PERT ANENTE
<br /> DESIGNATION SYMBOLS POWER SYMBOLS WIRING DEVICE SYMBOLS LUMINAIRE SYMBOLS FIRE ALARM SYMBOLS ABBREVIATIONS Project
<br /> Kaiser Permanents Everett
<br /> FIRE ALARM,
<br /> O KEY NOTE TAG
<br /> MOTOR OUTLET 120V,SINGLE RECEPTACLE OUTLET RECESSED TROFFER O'H SEEIBLE SPECIFICATONS(H=HIGH LEVEL),CHIME OR SPEAKER, A,AMP AMPERE IG ISOLATED GROUND. MOB BaCkfIII
<br /> -0 120V,ABOVE COUNTER SINGLE RECEPTACLE OUTLET SURFACE TROFFER �(CD VISUAL FIRE ALARM,(CD=CANDELLA) AC ALTERNATING CURRENT HP HORSEPOWER
<br /> DETAIL REFERENCE BUBBLE FUSED DISCONNECT SWITCH 2929 PINE STREET
<br /> A DETAIL NUMBER SWITCH XXIXXIXX=AMPSWITCH/POLESIAMPFUSE 120V,DUPLEX RECEPTACLE OUTLET 0 SURFACE LINEAR I-)C( VISUAL FIRE ALARM,WALL MOUNTED ACT ABOVE COUNTER TOP HPF HIGH POWER FACTOR EVERETT,WA 98201
<br /> E1.1 SHEET BEARING DETAIL HEAVY DUN NON-FUSED DISCONNECT SWITCH 120V,ABOVE COUNTER DUPLEX RECEPTACLE OUTLET SURFACE STRIP AUDIBLENI$UAL COMBO FIRE ALARM,(H=HIGH LEVEL,CD=CANDELLA) AIC AMPERE INTERRUPTING CAPACITY HRS HORSEPOWER RATED TOGGLE SWITCH
<br /> EY SWITCH XXIXX=AMP SWITCHIPOLES D CHIME OR SPEAKER,SEE SPECIFICATIONS Prepared for
<br /> 120V,CONTROLLED DUPLEX RECEPTACLE OUTLET ® EXIT SIGN CEILING MOUNT-ARROW AND FACES AS SHOWN ON PLANS ®a AUDIBLEIVISUAL COMBO FIRE ALARM,CEILING MOUNTED AFT ABOVE FINISHED FLOOR LED LIGHT EMITTING DIODE KAISER FOUNDATION
<br /> EF-1 EQUIPMENT TAG ® MOTOR STARTER 120V,5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET EXIT SIGN WALL MOUNT-ARROW AND FACES AS SHOWN ON PLANS © FIRE ALARM SMOKE DETECTOR O AEG ABOVE FINISHED GRADE LLF LIGHT LOSS FACTOR
<br /> HEALTH PLAN, INC.
<br /> 120V,ABOVE COUNTER 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET o- FIRE ALARM DUCT DETECTOR ATS AUTOMATIC TRANSFER SWITCH LRC LIGHTING RELAY CABINET
<br /> COMBINATION MOTOR STARTER NATIONAL FACILITIES SERVICES
<br /> 120V,CONTROLLED 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET FIRE ALARM FIRE/SMOKE DAMPER AF FRAME RATING IN AMPERES MCB MAIN CIRCUIT BREAKER POST OFFICE BOX 12916
<br /> S HP RATED TOGGLE DISCONNECT SWITCH 120V,DOUBLE DUPLEX RECEPTACLE OUTLET EMERGENCY SYMBOLS AS SWITCH RATING IN AMPERES MLO MAIN LUGS ONLY OAKLAND,CA94604
<br /> CONDUIT SYMBOLS M �
<br /> VFD VARIABLE FREQUENCY DRIVE 120V,ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE OUTLET AT TRIP RATING IN AMPERES MCA MINIMUN CIRCUIT AMPS
<br /> CONDUIT INSTALLED CONCEALED ABOVE CEILINGS,IN WALLS IN FINISHED 120V,CONTROLLED DOUBLE DUPLEX RECEPTACLE OUTLET EMERGENCY SURFACE STRIP FIRE ALARM KEYED NOTES AWG AMERICAN WIRE GAUGE MOCP MAXIMUM OVER CURRENT PROTECTION
<br /> AREAS,OR EXPOSED IN UNFINISHED AREAS
<br /> AUTOMATIC TRANSFER SWITCH 120V,5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET EMERGENCY RECESSED THE FOLLOWING AV AUDIO VISUAL (N) NEW
<br /> CONDUIT INSTALLED BELOW FINISHED FLOOR OR BELOW GRADE O FURTHER EFINENTHE SYMBOL:
<br /> OTATIONS AY BE USED WITH SMOKE DETECTOR TO
<br /> T1 120V,ABOVE COUNTER 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE EMERGENCY SURFACE I PHOTOELECTRIC C CONDUIT N NEUTRAL
<br /> 45K =
<br /> CONDUIT TURNING UP I = IONIZATION CONTRACTOR FURNISHED OWNER
<br /> �l..11.l QVA � 120V,CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE CF01 NC NORMALLY CLOSED
<br /> TRANSFORMER � EMERGENCY PENDANT Pll = COMBINATION PHOTOELECTRICIIONIZATION INSTALLED
<br /> 0 CONDUIT TURNING DOWN ryv Y BT = BE TRANSMITTER NATIONAL ELECTRICAL
<br /> CKT CIRCUIT NIL ki
<br /> SPECIAL PURPOSE RECEPTACLE,VOLTAGE AND NEMA AS NOTED BR = BEAM RECEIVER MANUFACTURER'S ASSOCIATION
<br /> HED
<br /> CONDUIT STUBBED OUT WITH BUSHING REFER TO LUMINAIRE DESIGNATIONS FOR FURTHER DIFFERENTIATION. S = SOUNDER BASE
<br /> II � WALL MOUNTED EQUIPMENT CONNECTION R = RELAY BASE CLG CEILING NIL NIGHT LIGHT
<br /> CONDUIT STUBBED OUT AND CAPPED TRANSFORMER ® E = ELEVATOR
<br /> EQUIPMENT CONNECTION CL CONNECTED LOAD NO NORMALLY OPEN
<br /> FLEXIBLE CONDUIT WITH SINGLE POINT OF CONNECTION AT CCT CORRELATED COLOR TEMPERATURE NTS NOT TO SCALE
<br /> ELECTRICAL EQUIPMENT G GENERATOR LUMINAIRE DESIGNATIONS
<br /> —C GROUNDING CONDUCTOR o o STATIONARY CIRCUIT BREAKER;RATING AS SHOWN ON PLANS FIRE ALARM GENERAL NOTES CRI COLOR RENDERING INDEX GFCI CONTRACTER OR
<br /> NST
<br /> CONTRACTOR INSTALLED
<br /> (D) DEMOLISH EXISTING OC OVER CURRENT Hellmuth,Obata&Kassabaum,Inc.
<br /> _-01= SWITCH AND FUSE;RATING AS SHOWN ON PLANS 1218 Third Avenue,Suite 1315
<br /> CONDUIT HOMERUN;ROUTE TO PANELBOARD,CABINET,OR TERMINAL Ri E-EXTERIOR OF DEMAND FACTOR PB PULL BOX Seattle,WA 98101 USA
<br /> BOARD INDICATED,AND TERMINATE CONDUCTORS TO CIRCUIT OVER �Ll-2,a P-PENDANT
<br /> GROUND ROD IN GROUND WELL A. PROVIDE A COMPLETE DESIGNIBUILD FIRE ALARM PACKAGE IN ACCORDANCE
<br /> CURRENT PROTECTIVE DEVICE WIRING DEVICE DESIGNATIONS CR R-RECESSED(CEILING OR WALL) WITH ALL CODES,REGULATIONS AND LOCAL AHJ. OILDESIGN LOAD fd PH PHASE It+1 206 493 1771 f+1 206 493 1778
<br /> WALL JUNCTION BOX(FLOOR PLAN SYMBOL) S-SURFACE MOUNTED(CEILING OR WALL) B. AT SUCH TIME THAT A PHYSICAL CONNECTION IS MADE BETWEEN EXISTING AND
<br /> T-TRACK NEW CONSTRUCTION WHEREBY THE NEW CONSTRUCTION BECOMES PART OF DC DIRECT CURRENT PNL PANEL AOrsproauoelor,&mtell.—I progeny rights reeer.ea
<br /> U-UNDERCABINET THE EXISTING BUILDING OR WHEN THE FIRE SEPARATION BETWEEN EXISTING
<br /> JO GEEING MOUNTED JUNCTION BOX(FLOOR PLAN SYMBOL) z
<br /> with
<br /> �22CIRCUIT NUMBER(WHERE SHOWN) X-EXIT I EMERGENCY SYSTEM SIMILAR TO THAT DESCRIBED ABOVE INCLUDING PULL STATIONS, DPDT DOUBLE POLE,DOUBLE THROW PVC POLYVINYL CHLORIDE CONDUIT
<br /> APPLICABLE CODES PUSH BUTTON STATION(FLOOR PLAN SYMBOL) 0-OWNER PROVIDED,CONTRACTOR INSTALLED NOTIR ATION DEVICES,HEAT DETECTORS,MONITOR MODULES AND POWER DPST DOUBLE POLE SINGLE THROW P POLE Mortensen
<br /> �T PANEL NAME-CIRCUIT
<br /> TRANSFORMER(FLOOR PLAN SYMBOL) SUPPLIES.TEMPORARY FIRE ALARM PROVISIONS SHALL BE MONITORED BY THE General Contractor
<br /> -2121 NFPA 70,NATIONAL ELECTRICAL CODE(NEC) ,SWITCH LEG OR CONTROL ZONE EXISTING FIRE ALARM SYSTEM.MAINTAIN TEMPORARY SYSTEMS IN OPERATION DIST DISTRIBUTION PWR POWER 10230 NE Points Drive,Suite 300
<br /> -2018 NFPA 99,HEALTH CARE FACILITIES CODE PUSH PLATE(FOR AUTOMATIC DOOR) (WHERE SHOWN) UNTIL PERMANENT FIRE ALARM EQUIPMENT IS INSTALLED,CONNECTED TO THE Kirkland,WA 98033
<br /> ©
<br /> -2016 NFPA 101,LIFE SAFETY CODE EXISTING SYSTEM,AND PLACED INTO OPERATION. (E) EXISTING TO REMAIN (R) RELOCATE EXISTING
<br /> -2019 NFPA 110,STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS BLANK-NORMAL C. FIRE ALARM CONDUCTORS AND CABLES SHALL BE ENCLOSED IN METAL CONDUIT.
<br /> PB PUSH BUTTON(FOR AUTOMATIC DOOR) ELM-
<br /> -20181-CODES(INTERNATIONAL CODES) FIRE ALARM CONDUIT SHALL BE IDENTIFIED BY RED PAINT. EC EMPTY CONDUIT RCP REFLECTED CEILING PLAN Mazzetti
<br /> -LOCAL CITY AND STATE AMENDMENTS D. AUDIBLE NOTIFICATION APPLIANCES SHALL GENERATE PRIVATE MODE SOUND MEP+FP Englneehng
<br /> 2771480 SURFACE MOUNTED PANELBOARD(FLOOR PLAN SYMBOL) PRESSURE LEVELS UNLESS OTHERWISE NOTED.
<br /> E. REFER TO MECHANICAL,PLUMBING AND FIRE PROTECTION DRAWINGS FOR DUCT ELEC ELECTRICAL RSC RIGID STEEL CONDUIT Seattle,e,WA 98121
<br /> 2013 Avenue,Suite 200
<br /> Seatt Tr— 2771480 FLUSH MOUNTED PANELBOARD(FLOOR PLAN SYMBOL) DETECTORS,SMOKE DAMPERS,TAMPER SWITCHES,FLOW SWITCHES,PRE-
<br /> ACTION OR DRY-TYPE SPRINKLER SYSTEMS REQUIRED TO BE MONITORED OR ELEV ELEVATOR SPOT SINGLE POLE,DOUBLE THROW
<br /> 120/208 SURFACE MOUNTED PANELBOARD(FLOOR PLAN SYMBOL) CONTROLLED BY THE FIRE ALARM SYSTEM.2018 WA STATE ENERGY CODE F. PROVIDE DUCT-MOUNTED SMOKE DETECTORS AS INDICATED ON THE E,EM EMERGENCY SPST SINGLE POLE,SINGLE THROW
<br /> T 120I208 FLUSH MOUNTED PANELBOARD(FLOOR PLAN SYMBOL) LIGHTING CONTROL SYMBOLS MECHANICAL DOCUMENTS.PROVIDE CEILING MOUNTED REMOTE INDICATOR AT EMT ELECTRO METALLIC TUBING SVJBD SWITCHBOARD
<br /> EACH DUCT DETECTOR.
<br /> 1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE G. SMOKE DAMPERS IN CORRIDOR WALLS SHALL CLOSE UPON SIGNAL FROM
<br /> WSEC, CORRIDOR SMOKE DETECTORS IN ACCORDANCE WITH IBC 715.3.2.1,METHOD 4. EMS EMERGENCY MANAGEMENT SYSTEM SWGR SWITCH GEAR
<br /> 2. AS REQUIRED BY SECTION C405.13 ALL LIGHTING SYSTEMS SHALL BE a a-SWITCH LEG(S) SMOKE DAMPERS IN NON-CORRIDOR WALLS SHALL CLOSE UPON SIGNAL FROM FA FIRE ALARM TB,TTB TERMINAL BACKBOARD
<br /> COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. ses DUCT MOUNTED SMOKE DETECTORS IN ACCORDANCE WITH IBC 715.3.2.1 METHOD
<br /> THE COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE 1.SEE MECHANICAL DOCUMENTS FOR LOCATIONS OF DAMPERS AND DUCT FSD FIRE SMOKE DAMPER TC TERMINAL CABINET
<br /> MANUFACTURERE'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED SINGLE LINE DIAGRAM LEGEND BLANK-SINGLE POLE SWITCH MOUNTED SMOKE DETECTORS.
<br /> THIRD PARTY AGENCY. 3-3 WAY SWITCH H. PROVIDE FIRE ALARM CONNECTIONS TO HVAC SYSTEM CONTROLS AND DEVICES
<br /> 3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT D-DIMMER FOR PROPER OPERATION,INCLUDING SHUTDOWN.SEE MECHANICAL FVNR FULL-VOLTAGE,NON-REVERSING TEL TELEPHONE
<br /> OCCUPANTS AND CONTROL THE LIGHTS INDICATED ON PLANS. K-KEY OPERATED DOCUMENTS FOR QUANTITIES,LOCATIONS,AND ADDITIONAL REQUIREMENTS.
<br /> 4. AS REQUIRED BY SECTION-408.1.3 THE COMMISSIONING DOCUMENTS (E)-EXISTING TO REMAIN OS-OCCUPANCY SENSOR SWITCH UPON DETECTION OF FIRE IN ANY AREA OF THE BUILDING(SMOKE,HEAT,OR FVR FULL-VOLTAGE,REVERSING V VOLT Key Plan
<br /> DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN T-TIMER SWITCH SPRINKLER FLOW)THE FIRE ALARM SYSTEM SHALL CAUSE THE AIR HANDLER OR FLA FULL LOAD AMPS(NAME PLATE) VD VOLTAGE DROP
<br /> 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. ———— (D)-DEMOLITION WORK AIR HANDLERS SERVING THE SMOKE COMPARTMENT WHERE THE ALARM
<br /> INITIATED TO SHUTDOWN,THE EXHAUST FANS ASSOCIATED WITH THAT SMOKE
<br /> (N)-NEW WORK COMPARTMENT TO SHUT DOWN,AND ALL SMOKE DAMPERS ASSOCIATED WITH FLC FULL LOAD CURRENT(NEC) VFD VARIABLE FREQUENCY DRIVE
<br /> THOSE FANS TO CLOSE.REFER TO ARCHITECTURAL PLANS FOR THE
<br /> (F)FUTURE WORK BOUNDARIES OF SMOKE COMPARTMENTS,AND REFER TO MECHANICAL DUCT (F) FUTURE VA VOLT AMPERES
<br /> OS1 #-DEVICE NUMBER PLANS FOR WHICH FANS SERVE EACH SPACE.SEE SPECIFICATIONS FOR GROUND FAULT
<br /> ELECTRICAL GENERAL NOTES 00NG FEEDER TAG a ADDITIONAL REQUIREMENTS FOR THE SEQUENCE OF OPERATION OF THE FIRE GFCI CIRCUIT INTERRUPTING W WATT
<br /> s,b-SWITCH LEG(S) ALARM SYSTEM.
<br /> z#-CONTROL ZONE(S) I. FIRE ALARM CONTROL AND MONITORING,INCLUDING AIR HANDLER SHUTDOWN G,GND GROUND W WIRE
<br /> A. ALL ELECTRICAL WORK SHALL COMPY WITH THE CURRENT APPROVED EDITION AND DAMPER CLOSURE SHALL BE ACCOMPLISHED USING SUPERVISED FIRE
<br /> OF THE NATIONAL ELECTRICAL CODE,AS ACCEPTED AND AMENDED BY LOCAL CS-CONTROL STATION ALARM WIRING TO WITHIN THREE FEET OF THE DEVICE BEING CONTROLLED OR GEN GENERATOR XFMR TRANSFORMER
<br /> OS-OCCUPANCY SENSOR MONITORED.FOR THE PURPOSE OF THIS MEASUREMENT ON AIR HANDLERS,THE
<br /> ORDINANCES. VS-VACANCY SENSOR MOTOR STARTER OR VFD IS THE DEVICE BEING CONTROLLED.FOR THE PURPOSE
<br /> B. WHERE GROUNDED CONDUCTORS OF DIFFERENT SYSTEMS ARE INSTALLED IN TS-TOUCH SCREEN OF THIS MEASUREMENT ON DAMPERS,THE DAMPER POWER CIRCUIT IS THE
<br /> THE SAME RACEWAY,CABLE,BOX,AUXILIARY GUTTER,ID OTHER TYPES PC-PHOTOCELL DEVICE BEING CONTROLLED,PROVIDED THE DAMPERS ARE SELF CLOSING AND
<br /> ENCLOSURE,EACH GROUNDED CONDUCTOR SHALL O IDENTIFIED BY SYSTEM HELD OPEN ELECTRICALLY.CONTROL SIGNALS SHALL ALSO BE SENT TO THE
<br /> PER NEC ARTICLE 200.E BRANCH MEANS OF IDENTIFICATION SHALL BE PERMANENTLY WITH STEM-WALL MOUNT BUILDING CONTROL SYSTEM(BAS),BUT THIS DOES NOT SATISFY THE
<br /> POSTED ATE 210 ),UNDERCUIT PANELBOARD. WITHOUT STEM-CEILING MOUNT REQUIREMENT FOR SUPERVISED FIRE ALARM CONTROL OF THE DEVICES. ELECTRICAL DRAWING INDEX Professional Seals
<br /> C. PER NEC ART 210.E SYSTEM
<br /> TEM SHALL
<br /> BE IDENTIFIED
<br /> CONDUCTORS OF MORE THAN ONE J. PROVIDE FIRE ALARM SYSTEM CONNECTION TO SECURITY LOCK SYSTEMS TO
<br /> OF NOMINAL VOLTAGE SYSTEM SHALL BE IDENTIFIED BY SYSTEM.PROVIDE MEANS UNLOCK EGRESS DOORS UNDER ALARM CONDITIONS.
<br /> D. PER NEC ART 1I55.2,FEEDER RID NTON AS REQUIRED EFICAITONR THIS RIS REQUIRED WHEN MORE THAN K. VISUAL NOTIFICATION DEVICE MOUNTING HEIGHT SHALL BE TO CENTER OF LAMP. 61 E001 ELECTRICAL SYMBOLS AND NOTES ,G C. SW�,
<br /> NOTES: L. COORDINATE LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS WITH B1 E002 NREC FORMS 4- DF WAS
<br /> ONE NOMINAL VOLTAGE SYSTEM EXISTS.PROVIDE MEANS OF IDENTIFICATION AS A. SWITCH LEG DESIGNATION USED FOR ROOM WITH STANDALONE LIGHTING MECHANICAL SYSTEMS.DETECTORS SHALL NOT BE IN DIRECT AIR FLOW OR B1 E003 NREC FORMS
<br /> REQUIRED PER THIS ARTICLE. CONTROLS. WITHIN 3 FEET OF SUPPLY DIFFUSERS. B1 E004 NREC FORMS
<br /> E. VERIFY FINAL PLACEMENT AND CONNECTION REQUIREMENTS PRIOR TO B. CONTROL ZONE DESIGNATION USED FOR LIGHTING CONTROL ZONES PART OF M. PROVIDE FIRE ALARM CONNECTIONS TO AUTOMATIC OPERATED DOORS TO B1 E005 ELECTRICAL SPECIFICATIONS
<br /> ROUGHING IN EQUIPMENT UTILITIES. PROGRAMMABLE LIGHITNG CONTROL PANEL. DISABLE AUTO DOOR OPENING UNDER ALARM CONDITIONS,EXCEPT FOR MAIN `
<br /> F. FINAL ACCEPTANCE OF WORK IN PLACE SHALL BE SUBJECT TO APPROVAL BY 81 E006 ELECTRICAL SCHEDULES
<br /> ESTIBULE DOORS OR UNLESS OTHERWISE NOTED.V .p
<br /> OWNER'S REPRESENTATIVE.INSTALLATION APPROVAL SHALL BE BASED ON B1 ED100E DEMO ELECTRICAL PLAN-LEVEL Pi-AREA E p �DDs9 �v
<br /> APPROVED SUBMITTAL,SHOP DRAWINGS AND LOCAL INSPECTIONS. B1 ED101E DEMO ELECTRICAL PLAN-LEVEL 1-AREA E � FOISTS
<br /> G. SUBMIT RED-LINE RECORD DRAWINGS WITHIN TWO(2)WORK WEEKS OF DATE of
<br /> NOTIFICATION OF FINAL APPROVAL Bi ED102E DEMO ELECTRICAL PLAN-LEVEL 2-AREA S TONAL
<br /> H. ALL WORK SHOWN ON DRAWINGS IS IN PART SCHEMATIC,INTENDED To CONVEY B1 ED102F DEMO ELECTRICAL PLAN-LEVEL 2-AREA F
<br /> SCOPE OF WORK AND GENERAL LAYOUT,VERIFY ALL EXISTING CONDITIONS AND Bl E10P1 OVERALL LEVEL P1 PLAN No. Description Data
<br /> MAKE ADJUSTMENTS AS REQUIRED.ELECTRICAL DRAWINGS ARE LARGELY B1 E101 OVERALL LEVEL 1 PLAN
<br /> DIAGRAMMATIC AND,THEREFORE,REPRESENT INSTALLATION INTENT AND 31 E102 OVERALL LEVEL 2 PLAN MOB BACK FILL ISSUED FOR PERMIT 2 0 2 2/1 0114
<br /> GUIDELINES;IT IS THE CONTRACTOR'S RESPONSIBILITY TO COVER ALL 31 E20PIE LIGHTING PLAN-LEVEL P1-AREA E
<br /> CONDITIONS ON HIS PREPARED SHOP DRAWINGS. Bi E201E LIGHTING PLAN-LEVEL 1-AREA E
<br /> I. PROVIDE UP-TO-DATE,ACCURATE,AND LEGIBLE CIRCUIT DIRECTORY WHICH
<br /> APPLIES TO PANELBOARDS AND SWITCHBOARDS AS REQUIRED BY NEC ART. B1 E202E LIGHTING PLAN-LEVEL 2-AREA E
<br /> 408.4 DIRECTORY SHALL BE LOCATED ON THE FACE OR ON THE DOOR OF EACH B1 E202F LIGHTING PLAN-LEVEL 2-AREA F
<br /> PANELBOARD OR AT EACH SWITCH ON A SWITCHBOARD.WITHIN EACH 31 E30PIE POWER FLOOR PLAN-LEVEL P1-AREA E
<br /> PANELBOARD PRIOR TO FINAL ACCEPTANCE OF WORK IN PLACE. B1 E301E POWER FLOOR PLAN-LEVEL 1-AREA E
<br /> J. LABEL ALL WIRING DEVICES WITH SOURCE PANELBOARD AND CIRCUIT NUMBER B1 E302E POWER FLOOR PLAN-LEVEL 2-AREA E
<br /> ON COVER PLATE.SEE SPECIFICATIONS.
<br /> K. LABEL ALL NEW PANELBOARDS,SWITCHBOARDS AND MOTOR CONTROL Bl E302F POWER FLOOR PLAN-LEVEL 2-AREA F
<br /> CENTERS WITH ENGRAVED LAMINATED-PLASTIC NAMEPLATES MOUNTED WITH B1 E40PIE FIRE ALARM FLOOR PLAN-LEVEL Pi-AREAE
<br /> CORROSION-RESISTANT SCREWS.SEE SPECIFICATIONS. B1 E401E FIRE ALARM FLOOR PLAN-LEVEL 1-AREA E
<br /> L. ALL INTERIOR OUTLET,JUNCTION AND PULL BOXES SHALL BE METALLIC,SIZED B1 E402E FIRE ALARM FLOOR PLAN-LEVEL 2-AREA E
<br /> PER CODE FOR THE NUMBER OF CONDUCTORS THEREIN. B1 E402F FIRE ALARM FLOOR PLAN-LEVEL 2-AREA F
<br /> M. ALL ELECTRICAL RACEWAYS SHALL BE CONCEALED IN THE WALLS AND ABOVE
<br /> SUSPENDED CEILING UNLESS OTHERWISE NOTED. B1 E601 PARTIAL ONE-LINE DIAGRAM
<br /> N. ALL CONDUCTORS SHALL BE#12 AWG MINIMUM TYPE THHN/THWN UNLESS 31 E701 ELECTRICAL DETAILS
<br /> OTHERWISE NOTED. Bi E801 PANEL SCHEDULES
<br /> 0. ALL CEILING MOUNTED ELECTRICAL DEVICES SHALL BE SUPPORTED FROM THE Bi E802 PANEL SCHEDULES
<br /> CEILING GRID,NOT FROM CEILING TILE.LIGHTING SHALL BE SUPPORTED FROM
<br /> STRUCTURE ABOVE.
<br /> P. ELECTRICAL PLANS ARE MOSTLY DIAGRAMMATIC.CONTRACTOR SHALL PROVIDE
<br /> CONNECTIONS BETWEEN FIXTURES AND LIGHTING CONTROL DEVICES SUCH AS
<br /> OCCUPANCY SENSORS,LIGHT SWITCHES,AND LIGHTING CONTROL PANEL TO
<br /> PROVIDE AN OPERABLE LIGHTING SYSTEM.
<br /> Q. IN THE EVENT OF ANY INCONSISTENCY BETWEEN ITEMS INDICATED ON THE
<br /> PLANS AND/OR THE SPECIFICATIONS,THE ONE WHICH PROVIDED THE MOST
<br /> COMPLETE WORK OR HIGHER STANDARD SHALL PREVAIL.
<br /> R. SUPPLY AND INSTALL ALL REQUIRED SUPPORTS AND BRACING OF EQUIPMENT
<br /> AND CONDUITS FOR PROPER EQUIPMENT INSTALLATIONS AND CODE
<br /> COMPLIANCE.
<br /> S. ALL EXPOSED CONDUITS SHALL BE INSTALLED AT RIGHT ANGLE TO ROOM OR
<br /> STRUCTURE.EXPOSED CONDUITS SHALL BE SUPPORTED FROM BUILDING
<br /> STRUCTURE USING APPROVED PIPE HANGERS.
<br /> T. ALL CONDUITS SHALL BE SIZED AS PER NEC UNLESS LARGER SIZES ARE NOTED
<br /> ON THE DRAWINGS.
<br /> U. ALL CUTTING,PATCHING AND PAINTING REQUIRED FOR THE CONCEALED
<br /> INSTALLATION OF CONDUITS SHALL BE PROVIDED BY THE CONTRACTOR.DO NOT
<br /> CUT OR DRILL STRUCTURAL MEMBERS WITHOUT WRITTEN APPROVAL FROM
<br /> STRUCTURAL ENGINEER,ALL CUTTING AND PATCHING SHALL BE NEAT,AND
<br /> PATCHING SHALL MATCH ADJACENT SURFACE AS To TEXTURE AND FINISH.
<br /> V. ALL PENETRATIONS THROUGH FIRE RATED WALLS,FLOORS OR CEILINGS SHALL
<br /> BE SEALED IN ACCORDANCE WITH A UL APPROVED SYSTEM THAT MAINTAINS THE KIP Pmject No: CAPD22246
<br /> INTEGRITY OF THE EXISTING FIRE RATING.PROVIDE AN ENCLOSURE of EQUAL HOK Project No: 20.05003.00
<br /> FIRE RESISTANT RATING AROUND ALL FIXTURES AND EQUIPMENT INSTALLED IN Sheet Title:
<br /> OR PENETRATING FIRE RATED SEPARATIONS.
<br /> W. ALL DATA CABLING TO BE
<br /> IITVENDOR.OWNERS'SITVENDOR.000RDINATE
<br /> ROUGH-NWORK WTH OWNER'S ELECTRICAL
<br /> SYMBOLS AND
<br /> NOTES