Laserfiche WebLink
• <br /> KAER <br /> PER ANENTE <br /> Project <br /> Kaiser Permanente Everett <br /> MOB Backfill <br /> 2929 PINE STREET <br /> LUMINAIRE SCHEDULE LUMINAIRE SCHEDULE GENERAL NOTES: EVERETT,WA 98201 <br /> MARK DESCRIPTION LOCATION MANUFACTURER MODEL LUMENS WATTS WATTSIFT CCT CRI FINISH DRIVER TYPE VOLTS NOTES A. THE LISTED MANUFACTURER NUMBERS MAY NOT BE COMPLETE.THE Prepared for <br /> CONTRACTOR IS RESPONSIBLE FOR FURNISHING LUMINAIRES WHICH P <br /> BR1 2'X4RECESSED ARCHITECTURAL TROFFER WITH INTEGRAL DIMMING AND POWER SUPPLY. PROJECT WIDE COLUMBIA LCAT24-35-HL-G-ED-U 5500 44W 3500K 80 WHITE 0.10V 277V COMPLY WITH THE MANUFACTURER NUMBER INDICATED AS WELL AS ALL KAISER FOUNDATION <br /> BR2 2'X2'RECESSED ARCHITECTURAL TROFFER WITH INTEGRAL DIMMING AND POWER SUPPLY. CORRIDOR COLUMBIA LCAT2235-MI 3300 29 W 3500K 80 WHITE 0-10V 277 V OTHER CRITERIA NOTED IN THE LUMINAIRE SCHEDULE,THE DRAWINGS, <br /> BR5 VXZ RECESSED ARCHITECTURAL TROFFER WITH INTEGRAL DIMMING AND POWER SUPPLY. CORRIDORS AXIS LIGHTING LCAT1235-LW-G-ED-U 2700 23W 3500K 80 WHITE 0-10V 277V AND DIVISION 26 SPECIFICATIONS.THE CONTRACTORIMANUFACTURER HEALTH PLAN, INC. <br /> BXi CEILING MOUNTED EDGE LIT LED EXIT SIGN WUTG OREMIUM GRADE EXTRUDED ALUMINUM HOUSING. CORRIDOR HEWILLIAMS EXIT/ELSF=-CP-AN-AC-D N/A 5W WA NIA ANODIZED ALUMINIUM WA 277V SHALL CONTACT ENGINEER PRIOR TO ORDERING,REGARDING ANY <br /> R9 RECESSED 4"DIA.DOWNUGHT WITH INTEGRAL DIMMING DRIVER AND POWER SUPPLY. PROJECT WIDE WILLIAMS,PRESCOLITE, 4DR-TL-1-20-9035-DIM-UNV+R-M-OF-CS-MW7-N 2000 20W 3500K 90 WHITE P10V 277V CONFLICTS BETWEEN THE SCHEDULE,DRAWINGS,AND SPECIFICATIONS. NATIONAL FACILITIES SERVICES <br /> ELEMENT B. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING POST OFFICE BOX12916 <br /> W3 WALL MOUNTED 2'WIDE HORIZONTAL VANITY LIGHT WITH INTEGRAL DIMMING DRIVER AND POWER PRIVATE RESTROOMS AXIS LIGHTING,TECH ARWLED-500-90-35S-2-FINISH-UNV-DP-1 1000 11 W 3000K 90 WHITE 0-10V 277 V THE CORRECT EXIT SIGN ORIENTATION,APPROPRIATE MOUNTING OAKLAND,CA 94604 <br /> SUPPLY.SEE ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS. LIGHTING BRACKETS,ILLUMINATED FACES,AND DIRECTIONAL CHEVRONS AS <br /> INDICATED ON PLANS. <br /> LUMINAIRE SCHEDULE KEYED NOTES: <br /> 1. REFER TO ARCHITECTURAL EXTERIOR ELEVATION FOR EXTENT OF <br /> PERFORATED TACKTL PANEL SYSTEM.LUMINAIRES TO BACK-LIGHT <br /> APPROXIMATELY 450 SF AREA. <br /> Hellmuth,Obata&Kassabaum,Inc. <br /> LIGHTING CONTROL DEVICE SCHEDULE LIGHTING CONTROL DEVICE SCHEDULE SeattlThird, A98101 Suite1315 <br /> Seattle,WA 98101 USA <br /> MARK DESCRIPTION MANUFACTURER MODEL FINISH NOTES GENERAL NOTES: t+1 206 493 1771 f+1 206 493 1778 <br /> CS1 LOW VOLTAGE ONE ZONE WALL BOX LIGHTING CONTROL STATION. NLIGHT NPODMA WHITE <br /> CS1X LOW VOLTAGE ONE ZONE WALL BOX LIGHTING CONTROL STATION WITH RAISE LOWER. NLIGHT NPODMIA-DX WHITE A. REFER TO APPROVED SHOP DRAWINGS FOR FINAL DEVICE SELECTIONS. AOzsp.oacotlbn&intelleptual p. fty right..eee.�.ea <br /> OS1 WALL BOX MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR WITH ONE ZONE CONTROL AND RAISE I LOWER. NLIGHT NWSX-PDT-LV-DX WHITE B. SHOP DRAWING SHALL FOLLOW PROJECT NAMING CONVENTIONS. In Association with <br /> OS3 CEILING MOUNTED,DUAL TECHNOLOGY OCCUPANCY SENSOR,WITH 360 DEGREE DISTRIBUTION. NLIGHT NCM-PDT-9 WHITE <br /> OS5 CEILING/CORNER MOUNTED,DUAL TECHNOLOGY OCCUPANCY SENSOR,WITH 120 DEGREE DISTRIBUTION. NLIGHT NM-PDT-16 WHITE C. WI RE AND I NSTALL ALL DEVICES PER MANUFACTURER'S WRITTEN Mortensen <br /> INSTRUCTIONS. <br /> General Contractor <br /> D. MODEL NUMBERS MAY NOT BE COMPLETE.PROVIDE DEVICES WHICH MEET 10230 NE Points Drive,Suite 300 <br /> SCHEDULE,DRAWING,AND DIVISION 26 SPECIFICATION REQUIREMENTS. Kirkland,WA 98033 <br /> Ma2Zetti <br /> MEP+FP EnglneeNng <br /> 2013 4th Avenue,Suite 200 <br /> Seattle,WA 98121 <br /> Key Plan <br /> EQUIPMENT SCHEDULE LIGHTING CONTROL MATRIX <br /> GENERAL NOTES: <br /> A STANDARD ABBREVIATIONS DO NOT APPLY TO EQUIPMENT"MARK"COLUMN. <br /> B.VERIFY CBIFUSE AND WIRING REQUIREMENTS WITH SUBMITTALS PRIOR TO WIRING EQUIPMENT. H <br /> C.REFER TO FEEDER SCHEDULE FOR WIRE AND CONDUIT SIZES BASED ON THE FEEDER TAG. O Y <br /> S f U <br /> NOTES: H <br /> 1.PROVIDE LOCAL DISCONNECTING SWITCH. <br /> w <br /> i _ f o <br /> ¢ r <br /> LD <br /> NEC FACTORY FEEDER WIRE& AVAIL.FAULT LL LL ', H = c�_+ _ � i o <br /> MARK MCA MOCP FLA LC HP KW KVA VOLTAGE POLES VFD DISCONNECT DISCONNECT TAG CONDUIT SIZE PANEL CKT# BRANCH CURRENT NOTES o LL o LL �_ 'O = = c o w <br /> TU-208 1.SA i5A 1kVA 480V 3 No i5N3P 20G (3)#12+(1)#12,314"C 2HA1 49,51,53 NORMAL 14,000A 1 O < O JQ O_ O ? N p O O <br /> TU-232 4.5 A 15 A 3 WA 480 V 3 No 15N3P 20G 3#12+1#12,3/4"C 2HA1 34,36,38 NORMAL 14,000 A 1 O Z�Z O O? O r F w w y z c7 z o <br /> () () Q j e 5 G j a s H Q s fw.t F O Professional Seals <br /> f f Q �a G N 6 z N <br /> ROOM TYPE OCC SENSOR DIMMING TIME CLOCK SWITCHES SYSTEM REMARKS <br /> OFFICE • 20 • • • • • • COORDINATE PARTIAL AUTO ON MANUAL ON PREFERENCE 4,OE MAS <br /> MIN WITH OWNER. a <br /> LARGE OFFICE 20 COORDINATE PARTIAL AUTO ON/MANUAL ON PREFERENCE O <br /> (>250 SO FT) • MIN • • • • • • WITH OWNER. - _ <br /> 20 COORDINATE PARTIAL AUTO ON ANDIOR TIME CLOCK ON 40943 <br /> OPEN OFFICE AREA 50% • MIN • • • • • • PREFERENCES AND SCHEDULE WITH OWNER �O Q O <br /> C{LFOlSTERF' <br /> 20 PARTIAL AUTO ON N SMAROL INCONFERENCE18TFLOOR <br /> OOCONFERENCE <br /> MANUAL TONAL <br /> CONFERENCE ROOM • MIN • • • • • • • ON AND SCENE CONTROL IN NED).RCONFERENCE <br /> CENTER(GONER LRG&CONFR MEDI. <br /> 50% PARTIAL OFF DURING NORMAL HOURS No. Description Data <br /> CORRIDOR 300% 10 10 • • • • • • • FULL OFF DURING AFTER HOURS MOB BACK FILL ISSUED FOR PERMIT 2022/10/14 <br /> MIN MIN COORDINATE TIME SCHEDULES WITH OWNER <br /> NOTES:1 CONTINUOUS DIMMING ARE CHOSEN BASED ON LIGHT SOURCE TYPE PER WSEC C405 <br /> 2 WHERE A PRIMARY DAYLIGHT ZONE AND A NON-DAYLIGHTING ZONE IS PRESENT,THE ZONES MUST BE SEPARATED.WSEC C405.2.4.1 <br /> 3 SET DAYLIGHT HARVESTING LOW END TRIM TO 15%.LIGHTS ARE INTENDED TO SHUT OFF FIXTURES IN ZONE COMPLETELY.WSEC C405.2.4.1&WSEC... <br /> 4 LUMINAIRES IN OR AT LEAST 50%WITHIN DAYLIGHTING ZONES MUST BE CONTROLLED.WSEC C405.2.4.1 <br /> 5 COORDINATE ON/OFF SCHEDULE TIMES WITH OWNER. <br /> 6 COORDINATE SCENE CONTROL REQUIREMENTS AND PROGRAMMING WITH OWNER. <br /> 7 CONTROLLED PLUG LOAD MUST BE 50%OF ALL 120V RECEPTACLES IN ROOM.IF ROOM IS OVER 200SF,(1)CONTROLLED RECEPTACLE PER 72"OF EACH <br /> UNCONTROLLED RECEPTACLE.COMPLY WITH WSEC C405.10 OCCUPANT SENSING REQUIREMENTS. <br /> 8 REFER TO SPECIFICATIONS FOR BAS SYSTEM INTEGRATION REQUIREMENTS. <br /> 9 LIGHTING CONTROL SYSTEM SHALL COMMUNICATE OCCUPANCY STATUS FOR EACH SPACE TO THE BAS. <br /> 10 LUMINAIRES TO AUTOMATICALLY SHUT OFF AS A FUNCTION OF DAWN/DUSK.WSEC C405.5 <br /> KIP Project No: CAP022248 <br /> HOK Project No: 20.05003.00 <br /> Sheet Title: <br /> ELECTRICAL <br /> SCHEDULES <br /> a <br /> oeglnal ie <br /> z Sheet Numbs, <br /> a <br /> B 1 E006 <br />