My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST 2 KAISER PERMANENTE 2025-01-27
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
2930 MAPLE ST 2 KAISER PERMANENTE 2025-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 8:20:12 AM
Creation date
12/31/2024 1:30:27 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Unit
2
Tenant Name
KAISER PERMANENTE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1E 2E 3E 4E 5E 6E 7E 8E 9E ELECTRICAL DEMO GENERAL... KAISER <br /> MANEME <br /> 1 COORDINATE WITH ARCHITECTURAL DRAWINGS FOR project <br /> E COMPLETE SCOPE OF DEMOLITION. Kals@I Permanents EV@I@tt <br /> 2 CONTRACTOR SHALL VISIT SITE PRIOR TO BID SUBMITTAL TO <br /> DETERMINE SITE CONDITIONS AFFECTING THE EXECUTION MOB Backfill <br /> OF WORK.FAILURE TO BE ACQUAINTED WITH EXISTING <br /> CONDITIONS WILL NOT BE JUSTIFICATION FOR ADDITIONAL 2929 PINE STREET <br /> SERVICES. 2929 PINE <br /> STREET <br /> EET <br /> 3 ANY EXISTING ELECTRICAL DEVICES LEFT WITHOUT POWER <br /> e e 98201 <br /> DUE TO THIS RENOVATION SHALL BE RECONNECTED TO prepared for <br /> SAME SIZE CIRCUIT(S)AS PRESENTLY SERVED.NO <br /> i TI <br /> ELECTRICAL DEVICES SHALL BE LEFT WITHOUT POWER. KAISER F O U N DAT I O N <br /> 4 EXISTING CONDUIT IN THE RENOVATED AREA SHALL BE HEALTH PLAN, INC. <br /> REUSED IF IT CAN BE LEFT IN PLACE OR IN GOOD CONDITION <br /> WHEN REMOVED.CONDUIT NOT INTENDED TO BE REUSED NATIONAL FACILITIES SERVICES <br /> SHALL BE REMOVED IF POSSIBLE(I.E.,NOT EMBEDDED IN POST OFFICE BOX 12916 <br /> CONCRETE FLOOR,ETC.) OAKLAND,CA 94604 <br /> SCOPE OF WORK D1 D D D4 5 CONDUCTORS IN RENOVATED AREA SHALL BE NEW.DO NOT <br /> 1 REUSE EXISTING WIRING UNLESS NOTED OTHERWISE. <br /> 6 IN ROOMS WHICH ARE BEING RENOVATED WHERE THE <br /> CEILING AND/OR WALLS ARE BEING TORN DOWN,THE <br /> REMOVED UNLESSOT ERWISE.IT ES,ETC.SHALL BE <br /> 7 THE OWNER SHALL HAVE FIRST REFUSAL OF ALL LIGHTING <br /> FIXTURES,DEVICES,ETC.SHALL BE REMOVED UNLESS <br /> NOTED OTHERWISE. <br /> 8 CIRCUIT BREAKERS ADDED TO EXISTING PANELS SHALLED , <br /> Q MATCH EXISTING BREAKERS TYPE,MANUFACTURE AND AIC <br /> I I I I I I I RATING.UPDATE DIRECTORIES IN EXISTING PANELS TO <br /> REFLECT4 CHANGES BY THIS RENOVATION. <br /> 9 EXISTING ELECTRICAL DEVICES ON REMAINING WALL SHALL <br /> I � I o REMAIN UNLESS OTHERWISE NOTED. <br /> L_ I I 1 10 EXISTING DEVICES TO REMAIN ARE INDICATED WITH A THIN Hellmuth,Obata&Kassabaum,Inc. <br /> 1 - 1 1218 Third Avenue,Suite 1315 <br /> SOLID LINE WEIGHT(AND SUBSCRIPT"EX). Seattle,WA 98101 USA <br /> 11 EXISTING DEVICES TO BE REMOVED OR RELOCATED ARE t+1 206 493 1771 f+1 206 493 1778 <br /> -_-- DENOTED WITH A HEAVY DASHED LINE WEIGHT. <br /> ° 12 FOR ANY DEVICES BEING REMOVED,REMOVE ASSOCIATED Allreprotlao41on a"'a"a°°°a'o.00anv is"°"�a^'e' <br /> i zozo <br /> BOXES,CONDUIT,AND WIRE BACK TO NEAREST DEVICE In Assoclatlon with <br /> I� REMAINING OR TO SOURECE UNLESS NOTED OTHERWISE. <br /> i 13 REMOVE ALL ABANDONED CONDUITS,JUNCTION BOXES, Mortensen <br /> General Contractor <br /> -- -— — — SUPPORTS,AND CABLES FROM ABOVE ACCESSIBLE <br /> CEILINGS INCLUDING,BUT NOT LIMITED TO,FIRE ALARM, 1023o NE Points Drive,Suite 300 <br /> I <br /> 1 <br /> TELECOMMUNICATIONS,CONTROL,AND POWER WIRING. Kirkland,WA 98033 <br /> EI <br /> 14 CONTRACTOR TO MAINTAIN CONTINUITY OF CIRCUITS Mazzetti <br /> L IF�: <br /> FEEDING DEVICES INDICATED TO REMAIN AND ANY CIRCUITS MEP+FP Englneetlng <br /> -- SERVICING DEVICES OUTSIDE THE PROJECT BOUNDARY. 2013 atn avenue,suite 200 <br /> 15 PROVIDE COVER PLATES WHERE MISSING ON EXISTING Seattle,WA 98121 <br /> JUNCTION BOXES.CONTRACTOR TO VERIFY QUANTITY IN <br /> THE FIELD. <br /> 16 CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING <br /> — — — — — — — — — — — — — — — — — — — — — — — AS NEEDED FOR EXECUTION OF DEMOLITION WORK AND <br /> INSTALLATION OF NEW WORK.CONTRACTOR PATCHING TO <br /> I I I I I I � I I I i MATCH FINISH AND CONSTRUCTION AS SPECIFIED BY <br /> ARCHITECT. <br /> I I <br /> - Key PI.n <br /> KEYNOTES <br /> I i I <br /> — I ED1 DISCONNECT AND REMOVE EXISTING RECEPTACLES AND <br /> —= I 1 POWER DEVICES IN CEILINGS AND WALLS THAT WILL BE <br /> DEMOLISHED.DEVICES IN EXISTING WALLS THAT WILL <br /> —— NOT BE DEMOLISHED SHALL REMAIN.REMOVE EXISTING <br /> WIRING AND CONDUIT BACK TO NEAREST JUNCTION BOX y <br /> TO REMAIN.MODIFY AND EXTEND EXISTING WIRING AS <br /> REQUIRED TO MAINTAIN CONTINUITY OF CIRCUIT TO <br /> T/ <br /> EXISTING DEVICES TO REMAIN. <br /> ED2 WHERE EXISTING CEILING WILL BE DEMOLISHED, <br /> REMOVE EXISTING LIGHTING AND CONTROLS.REMOVE <br /> EXISTING WIRING AND CONDUIT BACK TO JUNCTION BOX Professional Seals <br /> 0 0 o FOR FUTURE CONNECTION OF NEW LIGHTING.MODIFY <br /> I AND EXTEND EXISTING LIGHTING CIRCUITS TO MAINTAIN <br /> CONTINUITY OF CIRCUIT TO EXISTING LIGHTING. a <br /> ED3 WHERE EXISTING CEILING WILL REMAIN,EXISTING _ <br /> LIGHTING SHALL ALSO REMAIN.WHERE A NEW WALL <br /> CONFLICTS WITH EXISTING LIGHTING,RELOCATE <br /> 40949 �V <br /> EXISTING LIGHTING AS REQUIRED TO ACCOMMODATE rsTE�`OGgZ�" <br /> LLIF] NEW WORK. Nat. <br /> _ ED4 EXISTING FIRE ALARM DEVICES IN THIS SCOPE <br /> — BOUNDARY TO BE DISCONNECTED AND REMOVED.Jit— No. Description Date <br /> MOB BACK FILL ISSUED FOR PERMIT 2022/10/14 <br /> 11F <br /> I I I I I I I <br /> I I I I I I I <br /> I I I <br /> I I I I I <br /> - - - - - - - - - - <br /> — — �1 — — — — $e — — — — — — — <br /> KIP Pmject N. CAP022248 <br /> FOR Project No: 20.05003.00 <br /> El sheet line: <br /> DEMO ELECTRICAL <br /> PLAN - LEVEL 2 - <br /> a � n <br /> AREA E <br /> onsi^ai is <br /> DEMO ELECTRICAL FLOOR PLAN - LEVEL 2 -AREA E SheelNumbe42 <br /> a B1 ED102E <br />
The URL can be used to link to this page
Your browser does not support the video tag.