My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2525 W CASINO RD BASE FILE 2025-01-03
>
Address Records
>
W CASINO RD
>
2525
>
BASE FILE
>
2525 W CASINO RD BASE FILE 2025-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 3:00:35 PM
Creation date
1/3/2025 2:44:49 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2525
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
en in ms el <br /> EVERETT RTU sy ste <br /> 5300 DENVER AVENUE SOUTH <br /> SEATTLE,WASHINGTON 98108 <br /> UNIT REPLACEMENT (2 TST_65°° <br /> THE PLANS AND SPECIFICATIONS HEREIN <br /> ARE OWNED BYAND FOR THE SOLE USE OF <br /> ACCO ENGINEERED SYSTEMS,INC.(-ACCO-), <br /> AND MAYNOT BE REPRODUCED OR USED <br /> BY OTHERS FOR ANY PURPOSE UNLESS <br /> AUTHORIZED BYACCO IN WRITING.ACCO <br /> SYMBOL LEGEND DRAWING INDEX CANNTION IN HE EVENT <br /> OF LAY,,WARRANTY,OR <br /> OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. <br /> HVAC PIPING <br /> w <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION w <br /> �/ Of AREA OF WORK <br /> (N)® �(E) Ew(rv)a EXISTING(E)RECTANGULAR SUPPLY AIR DUCT RISER E] ® PPLV AIR GRILLE EUMAnc zw-cv ® FLEX CONNECTOR 10 <br /> QQ DRAWING INDEX KEY: 0 w <br /> (N) <br /> m() NEW a EXISTING(E)RECTANGULAR OUTSIDE AIR DUCT RISER URN AIRGR1UE ICI PNEUMATIC 3w cv N RUBBER SPHERICAL CONNECTOR N E m NOT INCLUDED WITH ISSUE W y <br /> NEW REVISED w <br /> (N)� Z(E) Fw(N)AEXISTING(E)RECTANGULAR RETURN AIR DUCT RISER X® ® HnUST GRILLE 'MI EUMAnc BUTTERFLY zw cv goo NO CHANGES <br /> IDLE GROOVED COUPLINGS I <br /> IMI O w <br /> KEY PLAN <br /> (N)® �(E) NEW(N)&UISTING(E)RECTANGULAR EXHAUST AIR DUCT RISER D RDUNDDIFFUBER _I+I_ PNEUMATIC BUTTERFLY BwaY(DIVERTING) E ENDCAP SHEET <br /> DRAWING TITLE Ln <br /> (N) ( I (E) NEW(N)a EXISTING(E)ROUND AIR DUCT RISER gUNEAR DIFFUSER t It PNEUMATIC BUTTERFLY sw-CV(MIXING) BLIND FLANGE NO. A <br /> M0.00 COVERSHEET 0p�9� sH"fr <br /> NEW SINGLE LINaa DOUBLE LINE RECTANGULAR OR Rourvo DUCT SIDE WALL GRILLE � Toarzsozwcv CONCENMIC REDUCER M0.01 CONSTRUCTION REQUIREMENTS 1111111 <br /> EXISTING SINGLE LINE&DOUBLE LINE RECTANGULAR OR ROUND DUCT WALL LOUVER ECCENTRIC <br /> ToarzEo awcv p CENTRIC REDUCER M0.02 PERMIT REQUIREMENTS 1111111 <br /> o <br /> �X—X--- OucrwoRK TO BE OFMousHFO(•x•oPrloN) r==� M1.R1 EQUIPMENT SCHEDULES,ROOF DEMO&HVAC PLANS 'FgEcrsrE'RE�ti.`` <br /> X—X—X ISTInGDouBLEL HE ou%.RKTOBEDSMousHEO(x oPnoN) 0 0 IRAL smEwnu(wITH ExTRAcroaawlTHouT EXTRACTOR) MoroarzeD BUTraRFLv zwcv III UNION M5.01 MECHANICAL DETAILS <br /> X—X y—/�/X//�, t1 <br /> 1� TT?T. IBTING DUCTWORK TO BE DEMOLISHED OPTION) I�I�I�II I�,��� SABLE DUCT ' TORGED BUTTERFLY 3 CV(DIVERTING) HRPDERVALVE EXPIRES:11-28-2024 <br /> 4"O® DUCT WITH WRAP.DIMENSIONS SHOWN ARE I.O.OF DUCT SECTON NUMBER SECTION DEFAULT—1 THIC.E.-I.E.UNLESS 07HERWEE NOTED ON PLANS MBOL SHEET NUMBER CALL OUT tMm« TORIZED BUTTERFLY 3W OW ARROW <br /> cv(MIXING) <br /> DucT WITH LINING.DIMENSIONS SHOWN ARE I.D.OF DUCT 2 2 3 glcal�M'SEUR RGTYPE 8s¢E DATE VALVE ESSUREGAUGEwTHSHUTOFFVALVE <br /> DEFAULT LINING THICKNESS=1'L.UNLESSOTHERWISE NOTEDON PLANS 1 (TYP 2) 4 CFM ttPM ICI <br /> L JIM SINGLE B DOUBLE LINE DUCTWORK WITH TRANSITIONAL FITTING #Q EQUIPMENT LABEL TAG >< SAILVALVE Y MPERATURE SENSOR B THERMOWELL <br /> U <br /> UARE[DDR.UND DOUBLELINE SQUARE TO ROUND TRANSInONALF-ING ® KINGQRDU--ERE PANEL BYGENERA1CDNTRACTQR � LL VALVE WITH MEMORY STOP � THERMOMETER <br /> (D o�} (I)KY-DIUSELBOWoSYSOLAREELBOWWITHTURNINGYANES --,L— OwARROWaFLOWARROW GORYED .DBEYA E T TES PLUG <br /> (D ® 0ND DUCT TURNING VERTICAL(DRECT.DUCT TURNING VERTICAL REVISICINCLOUD � BUTTERFLYVALVE Fsp OW SWITCH <br /> —�--r SINGLEUNF MANUAL IN A ALVOLUME OAMaErz �•0 1 CCO ONTR T.PLINE WITH TRAPTO APPROVED RECEPTOR BY PLUMBING CHECKVALVE \EEU IPLE DUtt VALVE <br /> MOTORIZED DAMPER(ELECTRIC) FLOOR SINK WITH CONTRACTOR <br /> TRAP TOAPPRoveD RECEPTOR BY PLUMBING RAWER LIEF VALVE <br /> TDRIZED DAMPER(PNEUMAnc) ( S7UBUP BY PLUMBING CONTRACTOR TRAINER WITH BLOWDOMA VALVE 4 AY wax VALVE <br /> FIRE OAMPER(SINGLE LINE AND DOUBLE LINE) COLD WATER STUBUP BY PLUMBING CONTRACTOR ^ 51a=T STRAINERu- CUUMBREAKER <br /> ❑1�1 ❑ FIRE...KE DAMPER(SINGLE LINE AND DOUBLE LINE) L.L <br /> cn_ev ELECTHIcAL CONTRACTOR � SUCTION DIFFUSER �T STEAM TRAP <br /> DSDSMOKEDETECTOR(DUCTTYPE) 0REVIBIONDELTA ARVENT-MANUAL ANGLEVALVE SCOPE OF WORK APPLICABLE CODES <br /> SP A 1.PRESSURE SENSOR INTOFCONrvEcrloN RVENT-AUTO ® HT GLAss <br /> 1. REMOVE AND REPLACE ROOFTOP PACKAGE UNIT WITH <br /> sD SMOKE DETECTOR(AREA TYPE) ® REGULATOR ESSUREREDUCINGVALVE 0 rERDRIER LIKE EQUIPMENT. WASHINGTON MECHANICAL PROJECTS: <br /> y ICI <br /> OT THERMosrAT WITH-NE NUMBER PRESSURESUSTAIN04GVALVE V_ sOLEN-VALVE ALL WORK SHALL BE IN FULL ACCORDANCE WITH APPLICABLE <br /> I�GI LOCAL,STATE,AND FEDERAL CODES,LAWS AND REGULATIONS. 1 12/13/2023 ISSUE FOR REVIEW TD <br /> ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH, <br /> CO zsarvsoR L TO FLOW coNraoL ® WITH SENSING BULB BUT NOT LIMITEDTO: No. Date Description By <br /> ® NozSENSOR CIRCUITSETTER PRESSURE <br /> GA <br /> STEAM • 2018 INTERNATIONAL BUILDING CODE WITH WA AMENDMENTS RBVISIODS <br /> O <br /> • 2020 NATIONAL ELECTRICAL CODE WITH WA AMENDMENTS <br /> ''''��r�"""" • 201:INTERNATIONAL MECHANICAL CODE WITH WA AMENDMENTS Pf02CS <br /> CO sarvsoR uvALVE WITH HOSE CONNECTIONPERErvnAL PRESSURE sarvsoR • 201 UNIFORM PLUMBING CODE WITH WA AMENDMENTS ) <br /> - • 2018 CCUPANCY SENSOR FLOW METER INLME HOSE BIBB <br /> WASHINGTON STATE ENERGY CODE <br /> QG <br /> • 2018 INTERNATIONAL FIRE CODE WITH WAAMENDMENTS EVERETT RTU <br /> O FM � <br /> FM UNIT REPLACEMENT <br /> ® MILL SWITCH OW METER TURBINE <br /> ALL WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING <br /> ABBREVIATIONSADDITIONAL GUIDELINES WHERE REQUIRED BY CODE: 2525 CASINO RD <br /> • SHEET METAL AND AIR CONDITIONING CONTRACTORS EVERETT,WA.98204 <br /> AFF ABOVE FINISHED FLOOR (D) DEMO HT HEIGHT OD OUTSIDE DIMENSION TSTAT THERMOSTAT NATIONAL ASSOCIATION(SMACNA) <br /> AHJ AUTHORfTY HAVING JURISDICTION CIA DIAMETER HHWR HEATING HOT WATER RETURN OPN'G OPENING TU TOP UP • AMERICAN SOCIETY OF HEATING,REFRIGERATION AND <br /> AP ACCESS PANEL DSD DUCT SMOKE DETECTOR HHWS HEATING HOT WATER SUPPLY OSA OUTSIDE AIR TYP TYPICAL AIR-CONDITIONING ENGINEERS(ASHRAE) <br /> ISO <br /> AREA SMOKE DETECTOR DWG DRAWING HPG HIGH PRESSURE GAS PLBG PLUMBING UBC UNIFORM BUILDING CODE • AMERICAN SOCIETY OF MECHANICAL ENGINEERS(ASME) <br /> BDD BACKDRAFT DAMPER (E) EXISTING HPS HIGH PRESSURE STEAM POC POINT OF CONNECTION UC UNDERCUT • AMERICAN SOCIETY OF CIVIL ENGINEERS(ASCE) Title <br /> BF BOTTOM FLAT EA EXHAUST AIR HVLS HIGH VELOCITY LOW SPEED FAN RECIP RECIPROCATING UGC UNDERGROUND • NATIONAL FIRE PROTECTION AGENCY(NFPA) <br /> BOD BOTTOM OF DUCT EG EXHAUSTAIRGRILLE ID INSIDE DIMENSION (R) RELOCATE UM UNIFORM MECHANICALCODE VICINITY MAP • OCCUPATIONAL SAFETY AND HEALTH ACT(OSHA) COVER SHEET <br /> BOP BOTTOM OF INSULATION ELB ELBOW INS INSULATION RA RETURN AIR UNO UNLESS NOTED OTHERWISE <br /> BOP BOTTOM OF PIPE ELEC ELECTRICAL INT INTERIOR REQ'D REQUIRED UTR UP THROUGH ROOF <br /> CA COMPRESSEDAIR EO EQUIPMENT (L) LINED REV REVISION V VENT = <br /> CD CONDENSATE EXH EXHAUST LR LINEAR RETURN RG RETURN OR TRANSFER GRILLE VAV VARIABLE AIR VOLUME <br /> CE CEILING EXHAUST EXT EXTERIOR LS LINEAR SUPPLY RG REFRIGERANT GAS VFD VARIABLE SPEED DRIVE <br /> CENTR CENTRIFUGAL (F) FUTURE MA MIXED AIR RGHP REFRIGERPNrGAS-HIGH PRESSURE VIF VERIFY IN FIELD <br /> CFF CAP FOR FUTURE FD FIRE DAMPER IMECHANICAL RH REHEAT VOL VOLUME <br /> CFM CUBIC FEET PER MINUTE FLEX FLEXIBLE MPG MEDIUM PRESSURE GAS RL REFRIGERANT LIQUID WMS WIRE MESH SCREEN PROPERTY INFORMATION <br /> CHWR CHILLED WATER RETURN IFLOOR MFR MANUFACTURER RMF RAPID MOUNT FRAME XFER TRANSFER T.DALGLEISH T.TOUTONGHI <br /> CHWS CHILLED WATER SUPPLY FLU FLUE MD MOTORIZED DAMPER RNA ROUND NECK ADAPTER I <br /> CL CENTERLINE FIR FLOOR RETURN MTD MOUNTED RND ROUND A. Designed By Checked By <br /> CLG CEILING FS FLOOR SUPPLY I METAL RR REFRIGERANT RELIEF - PARCEL#:28041400201700 T.DALGLEISH T.MATSUSHIMA <br /> CMU CONCRETE MASONRY UNIT FSD FIRE SMOKE DAMPER IMAKE UP AIR IRS REFRIGERANT SUCTION <br /> CO COOLING ONLY GA GAUGE IMANUAL VOLUME DAMPER SA SUPPLY AIR <br /> CA COMBUSTION AIR GALV GALVANIZED NG NATURAL GAS SG SUPPLY GRILLE LEGAL DESCRIPTION:SEC 14 TWP 28 RGE 04 1-RT-6A)IN 200 Drawn By Project Manager <br /> CONC CONCRETE GC GENERAL CONTRACTOR (N) NEW SM SHEET METAL FT OF E 863.13 FT OF N 665.04 FT OF NW1/4 NW1/4 LESS CO 2873742 AS SHOWN <br /> COND CONDENSATE GEXH GREASE EXHAUST N/A NOT APPLICABLE SS STAINLESS STEEL - RD LESSST HWY TGW W 20OFT OF E 663.13FT OF N 665.04 FT <br /> CONN CONNECTION GPH GALLONS PER HOUR INC NORMALLY CLOSED STD STANDARD •• OF NW1/4 NW1/4 LESS N 30 FTLESS S/HY TGW W 100 FTOF Job Number Scale <br /> CONT'R CONTRACTOR GPM GALLONS PER MINUTE NIC NOT IN CONTRACT TA TRANSFER AIR E463.13 FT OF N 665.04FT OF NW1/4 NW1/4 LESS N 30FT FOR <br /> CR CEILING RETURN GR GLYCOL RETURN NO NORMALLY OPEN TD TOP DOWN CO RD LESS ST HWY M O.0 0 <br /> CS CEILING SUPPLY GS GLYCOL SUPPLY NTS NOT TO SCALE TF TOP FLAT <br /> CWR CONDENSER WATER RETURN GYP GYPSUM BOARD OBD OPPOSED BLADE DAMPER TOD TOP OF DUCT <br /> CWS CONDENSER WATER SUPPLY HOA HAND-OFF-AUTO OC ON CENTER TOP I TOP OF PIPE <br />
The URL can be used to link to this page
Your browser does not support the video tag.