My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2525 W CASINO RD BASE FILE 2025-01-03
>
Address Records
>
W CASINO RD
>
2525
>
BASE FILE
>
2525 W CASINO RD BASE FILE 2025-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 3:00:35 PM
Creation date
1/3/2025 2:44:49 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2525
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
installation 4. Support piping so that no strains are imposed on unit or <br /> PIPING controls. <br /> CAUTION 5. Use two wrenches when connecting piping to unit <br /> controls. <br /> Gas pressure to unit heater controls must never exceed <br /> 14"W.C. 6. Provide a drip pocket before each unit and in the line <br /> w <br /> Testing Piping System. The appliance and its indi- <br /> here low spots cannot be avoided. (see Figure 4). <br /> vidual shutoff valve must be disconnected from the 7. Take-off to unit should come from top or side of main to <br /> gas supply piping system during any pressure testing avoid trapping condensate. <br /> if the test pressure is in excess of 1/2 psi. g. Piping,subject to wide temperature variations,should <br /> The appliance must be isolated from the gas supply be insulated. <br /> piping system by closing its individual manual shutoff <br /> valve during any pressure testing of the gas supply 9. Pitch piping up toward unit at least 1/4" in 15' of <br /> system at test pressures equal to or less than 1/2 psi. horizontal run. <br /> 10. Compounds used on threaded joints of gas piping must <br /> be resistant to action of liquefied petroleum gases. <br /> 1. Installation of piping must be in accordance with local 11. Purge air before lighting unit by disconnecting pilot <br /> codes,and ANSI Z223.1-Latest Edition,"National Fuel Gas tubing at gas valve.In no case should line be purged into <br /> Code,"or CAN/CGA-B149.1 and .2 in Canada. Do not use heat exchanger. <br /> flexible connectors. ' <br /> 12. After installation, the system must be checked for <br /> 2. Piping to units must conform with local and national require- leaks. Use soap solution. <br /> ments for type and volume and gas handled,and pressure 13. Install a ground joint union and a gas cock upstream of <br /> drop allowed in the line. Refer to Table 4,to determine the the unit for easy servicing of controls,including a'/9"NPT <br /> cubic feet per hour(cfh)for the type of gas and size of unit to plugged tapping accessible for test gage connection.(See <br /> be installed. Using this cfh value and the length of pipe Figure 4). <br /> necessary,determine the pipe diameter from Table 1.Where <br /> several units are served by the same main,the total capacity, 14. Allow at least 5 feet of piping between any high <br /> cfh,and length of main must be considered.Avoid pipe sizes pressure regulator and unit control string. <br /> smaller than '/2". Table 1 allows for the usual number of <br /> fittings with a0.3"W.C.presuredrop.Where the gas supplied 15. Testing Piping System.The appliance and its individual <br /> gas a specific gravity other than 0.60, apply the multiplying shutoff valve must be disconnected from the gas supply <br /> factor given in Table 2 to the flow capacities in Table 1 to piping system during any pressure testing if the test <br /> determine total flow capacity. pressure is in excess of psi. <br /> The appliance must be isolated from the gas supply <br /> 3. After threading and reaming the ends, inspect piping piping system by closing its individual manual shutoff <br /> and remove loose dirt and chips. valve during any pressure testing of the gas supply <br /> system at test pressures equal to or less than 1/2 psi. <br /> table 1 / gas pipe capacities <br /> In Cu. Ft. per Hour with Pressure Drop of 0.3 in. W.C.with Specific Gravity 0.60 <br /> Length DIAMETER OF PIPE-INCHES <br /> of Pipe <br /> in Ft. +/z % 1 1+/. 1+% 2 3 4 6 a <br /> 15 76 218 440 750 1220 2480 6500 13880 38700 79000 <br /> 30 73 152 285 590 890 1650 4700 9700 27370 55850 <br /> 45 44 124 260 435 700 1475 3900 7900 23350 45600 <br /> 60 50 105 190 400 610 1150 3250 6800 19330 39500 <br /> 75 97 200 345 545 1120 3000 6000 17310 35300 <br /> 90 88 160 320 490 930 2600 5400 15800 32250 <br /> 105 80 168 285 450 920 2450 5100 14620 1 29850 <br /> 120 158 270 420 860 2300 4800 13680 27920 <br /> 150 120 242 380 710 2000 4100 12240 25000 <br /> 180 128 1 225 350 1 720 1950 1 4000 11160 22800 <br /> 210 205 320 660 1780 3700 10330 21100 <br /> 240 190 300 620 1680 3490 9600 19740 <br /> 270 178 285 580 1580 3250 9000 18610 <br /> 300 170 270 545 1490 3000 8500 17660 <br /> 450 140 226 450 1230 2500 7000 14420 <br /> 600 119 192 380 1030 2130 1 6000 12480 <br /> GAS <br /> table 2 / specific gravity conversion SUPPLY LINE <br /> factors GROUND <br /> 1 GAS JOINT <br /> Multiplying factors to be used with Table 1 when the COCK UNION <br /> specific gravity of gas is other than 0.60. GAS \ <br /> SUPPLY LINE .:-- <br /> NATURALGAS PROPANE GAS <br /> Specific Factor Specific Factor <br /> Gravity Gravity 3" CONTO <br /> TROLS <br /> 0.55 1.04 1.50 0.633 MIN. PLUGGED <br /> 0.60 1.00 1.53 0.626 ye"NPT TEST <br /> GAGE CONNECTION <br /> 0.65 0.962 1.60 0.612 <br /> Figure 4 <br /> DRIP Recommended piping to controls <br /> POCKET <br /> Page 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.