ENERGY RECOVERY UNIT SCHEDULE W z <br /> z <br /> _ w <br /> IDENTIFIER PERFORMANCE TEMP RECOVERY EFFICIENCY% ENTHALPY RECOVERY EFFICIENCY% ELECTRICAL SPECIFICATIONS (n -I O <br /> �J ) O z <br /> EXTERNAL O 0 <br /> BASIS OF DESIGN STATIC DUCT SOUND COOLING 0 15%/ HEATING 0 15%/ COOLING 0 15%/ HEATING 0 15%/ POWER V <br /> T'4Cs DESIGN MODEL AIRFLOW PRESSURE CONNECTION PRESSURE 100%AIRFLOW 100%AIRFLOW 100%AIRFLOW 100%AIRFLOW SUPPLY MCA/MOPD DIMENSIONS WEIGHT NOTES <br /> (EX-HIGH) <br /> ERV-I DAIKIN VAM12000VJU 1200 .56 14'0 35 DBA 14%/12% 13%/10% 52%/43% 63%/60% 205/230-1-60 5.1/15 30-i/8 X 63-3/4 X 41-3/16 346 1,2 W I ' I W 2 <br /> %ERV-2 DAIKIN VAM1200GVJU 1200 .56 14"0 38 DBA 14%/12% 13%/10 52%/49% 63%160% 205/230-1-60 5.1 115 30-1/8 X 63-3/4 X 41-13/16 346 1,2 Z a_ <br /> I. PROVIDE WIRELESS CONTROLLER. n/ F, x <br /> 1 2. PROVIDE FILTER UPSTREAM OF ERV FOR OUTSIDE AIR AND EXHAUST AIR SEE FILTER SCHEDULE FOR DETAILS. n� ¢ m <br /> a2 a <br /> AIR FILTER SCHEDULE vRF OUTDOOR UNIT SCHEDULE <br /> IDENTIFIER PERFORMANCE IDENTIFIER PERFORMANCE ELECTRICAL <br /> 4311( <br /> FILTER HOUSING PRESSURE TAG MAKE MODEL NOMINAL TONS FACTORY REFER TYPE REFER SIZES SOUND POWER MCA/MOPD DIMENSIONS WEIGHT NOTES <br /> TAG MAKE MODEL UNIT SERVED DIMENSION FILTER SIZE VELOCITY DROP IN.WG NOTES CHARGE (LIQUID/SUCTION) DBA SUPPLY <br /> ODU-1 CARRIER 38VMAI2ORDS5-I 10 26.5 LBS R-410A 3/4/I-1/S 62.1 206/230-3-60 46/50 31-1/8 X 52-3/4 X 64-3/8 612 LBS <br /> F-1 OMNI BUILT ERV-I 24 X 24 24 X 24 300 FPM .15 ODU-2 CARRIER 38VMAI68RDS5-1 14 44.2 LBS R-410A 1/8/I-I/8 63.3 208/230-3-60 10/50 18-3/8 X 31-I/8 X 64-3/8 1131 LBS <br /> F-2 OMNI BUILT ERV-2 24 X 24 24 X 24 300 FPM .15 I. NONE <br /> L NONE <br /> BRANCH CONTROLLER SCHEDULE <br /> IDENTIFIER PERFORMANCE _ ELECTRICAL ODU TO MAIN MDC MAIN MDC TO SUB MDC SPECIFICATIONS <br /> CONNECTED CAPACITY MAX CAPACITY MAX CONNECTED SOUND POWER HIGH HIGH DESIGN <br /> TAG MAKE MODEL PORTS PORTS UTILIZED PER PORT CAPACITY DBA SUPPLY MCA/MOPD PRESSURE LOW PRESSURE PRESSURE LOW PRESSURE LIQUID LINE PRESSURE DIMENSIONS WEIGHT NOTES <br /> PSIG <br /> BC-I CARRIER 40VMD010M-3 10 ' 0 0 BTU/H 54K BTU/H 360K BTU/H 32.1 205/230-1-60 1.05/15 5/5-I-I/8 3/4-1-3/8 5/5-1/5 3/4-I-1/8 3/5-5/8 480/320 44-1/2 X 18 X 33-I/8 143 LBS <br /> BC-2 CARRIER 40VMD010M--3 10 0 0 BTU/H 54K BTU/H 360K BTU/H 32.1 208/230-I-60 1.05/15 5/5-I-I/S 3/4-I-3/8 5/5-1/5 3/4-I-1/8 3/5-5/S 480/320 44-1/2 X 18 X 33-I/S 143 LBS <br /> I. NONE <br /> OUTSIDE AIR DUCT ENSURE BASE IS LEVEL AND <br /> WEIGHT IS EVENLY DISTRIBUTED <br /> ODU-I <br /> FILTER F I, F-2 <br /> ACCESS 24X24X2„ VIEW B BASE MUST BE MADE <br /> CLEARANCE T 111111: <br /> MERYS FILTER ■�� OF SOLID STRUCTURE <br /> i. III 8`MIN.14,E TO ERV �i FINISHED ROOF ODU-I <br /> ROOF MEMBRANE `Ajti=/iempzea-=`AjNiw / -- 2,-b'- / / U) <br /> 2'-2" 2' DECKING <br /> " 4'MIN PER MFG.INSTRUCTIONS SUPPORT RAILS 8„ I 1-10A ,{ 4"/ <br /> NUT SO -r r I I O <br /> i h I I I OO <br /> 1-5/6`UNISTRUT-H I I I —I I Ill <br /> ALL THREAD , I I <br /> Vs'RUBBER PAD <br /> WATERPROOFING MEMBRANE ; r - - \ - -- H Li <br /> #1 SIDE VIEW : FILTER HOUSING AT OUTSIDE AIR DROP #3 VIEW 'A': RTU SUPPORT SEAMS L-BRACKET (n N <br /> NUT Xl 3: a OD <br /> :: <br /> I/2'LAG BOLT CM):TYPE AND _� -5"MIN.AESOVE FINISHED ROOF <br /> OUTSIDE AIR DUCT TO ROOF .._ LENGTH BAM,UBDETERMINED BY ENGINEER0- LJ Q Q <br /> _ JOIST 6`ODE BEAM,H TO BE- 1'-10��1D r <br /> - - -- DETERMINED EST ENGINEER AND - <br /> 14"DUCT TO ERV _ STRUCTURAL C NvmoNs. \ J O� <br /> - 3/9•ALL-THREAD Z�l- <br /> �LL <br /> nWASHER EA / / 5�'"TYP. <br /> 2" FILTER HOUSINGIlliii ��// SIDE 2 <br /> � 5116'LAGu <br /> ' 133213 'gig <br /> 101, <br /> , Too. <br /> BOLT U/ a <br /> /�, PLENUM WASHER <br /> DN <br /> ie In <br /> �w <br /> Lu <br /> �> <br /> • J $Nw <br /> D . 1 <br /> D N <br /> #2 ISOMETRIC VIEW : FILTER HOUSING AT OUTSIDE AIR DROP #5 ERv HANGING SUPPORT DETAIL #4 VIEW 'S' RTU SUPPORT DETAILS ENLARGED 0 z Q LL <br /> TYP. I <br /> u', a4 <br /> V °` "" <br /> CJ I <br /> 'I'` Z co <br /> LJ Q W Ili <br /> RE IEWED FORPERM11 2 _ g o z <br /> a. , aZg <br /> W <br /> O = M3.0 <br /> w <br />