My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE WATERLINE GYM 2025-01-10
>
Address Records
>
GRAND AVE
>
2900
>
WATERLINE GYM
>
2900 GRAND AVE WATERLINE GYM 2025-01-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2025 11:18:32 AM
Creation date
1/10/2025 10:33:41 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
WATERLINE GYM
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Project Title: • <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Concrete Column Project File:COL LAT DEFLECTION.ec6 <br /> LIC#:KW-06016450,Build:20.21.12.16 QUANTUM CONSULTING ENGINEERS (c)ENERCALC INC 1983-2021 <br /> DESCRIPTION: (e) 16x24 <br /> Code References <br /> Calculations per ACI 318-14, IBC 2018 <br /> Load Combinations Used : IBC 2018 <br /> General Information <br /> fc:Concrete 28 day streng = 6.0 ksi Overall Column Height = 18.0 ft <br /> E= = 3122 ksi End Fixity Top&Bottom Pinned <br /> Density = 150 pcf Brace condition for deflection(buckling)along colun <br /> Q = 0.750 X-X(width)axis: <br /> fy-Main Rebar = 60 ksi Unbraced Length for buckling ABOUT Y-Y Axis=18.0 ft, K=1.0 <br /> E-Main Rebar = 29000 ksi Y-Y(depth)axis: <br /> Allow.Reinforcing Limits ASTM A615 Bars Used Unbraced Length for buckling ABOUT X-X Axis=18.0 ft,K= 1.0 <br /> Min.Reinf. = 1 % <br /> Max.Reinf. = 8% <br /> Column Cross Section <br /> Column Dimensions: 24.Oin high x 16.0in Wide, Column - <br /> Edge to Rebar Edge Cover= 2.0in <br /> Column Reinforcing: 4-#9 bars @Corners„ 2-#9 bars <br /> left& right between corner bars <br /> •w •. I <br /> Applied Loads Entered loads are factored per load combinations specified by user. <br /> Column self weight included : 7,200.0 lbs` Dead Load Factor <br /> AXIAL LOADS . . <br /> Axial Load at 18.0 ft above base, D=243.0, L= 103.0 k <br /> BENDING LOADS . . <br /> Lat. Point Load at 9.0 ft creating Mx-x, E =5.0 k <br /> DESIGN SUMMARY <br /> Load Combination +1.20D+1.60L Maximum SERVICE Load Reactions. <br /> Location of max.above base 17.879 ft Top along Y-Y 0.0k Bottom along Y-Y 0.0 k <br /> Maximum Stress Ratio 0.371: 1 Top along X-X 2.50 k Bottom along X-X 2.50 k <br /> Ratio=(Pu^2+Mu^2)^.5/(PhiPn^2+PhiMn^2)^.5 <br /> Pu= 465.040 k 'Pn= 1,246.75 k 0.0184 X Cd = <br /> (pi* <br /> Mu x= 56.674 k-ft (Q*Mn-x= 150.455 k-ft Maximum SERVICE Load Deflections.. 0.092 <br /> Mu-y= 0.0 k-ft (Q`Mn-y= 0.0 k-ft for load combination <br /> E Only <br /> Mu Angle= 0.0 deg Along X-X 0.0in at 0.0 ft above base <br /> V1u at Angle= 56.674 k-ft (p1n at Angle= 153.375 k-ft for load combination: <br /> Pn&Mn values located at Pu-Mu vector intersection with capacity curve <br /> General Section InformatioitQ = 0.650 B =0.750 e = 0.80 <br /> Column Capacities.. <br /> Pnmax:Nominal Max.Compressive Axial Capaci 2,397.60 k p <br /> %Reinforcing 2.083 % Rebar /o Ok <br /> Pnmin:Nominal Min.Tension Axial Capacity k Reinforcing Area 8.0 inA2 <br /> (P Pn,max:Usable Compressive Axial Capacity 1,246.75 k Concrete Area 384.0 inA2 <br /> (I)Pn,min:Usable Tension Axial Capacity k <br /> Governing Load Combination Results <br /> Governing Factored Moment Dist.from Axial Load Bending Analysis k-ft <br /> Utilization <br /> Load Combination <br /> X-X Y-Y base ft Pu "Pn g x gx*Mux g y gy`Muy Alpha (deg) 8 Mu (pMn Ratio <br /> +1.40D M2,min 17.88 350,281,246.75 1.000 38.53 0.000 38.53 135.56 0.283 <br />
The URL can be used to link to this page
Your browser does not support the video tag.