My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE WATERLINE GYM 2025-01-10
>
Address Records
>
GRAND AVE
>
2900
>
WATERLINE GYM
>
2900 GRAND AVE WATERLINE GYM 2025-01-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2025 11:18:32 AM
Creation date
1/10/2025 10:33:41 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
WATERLINE GYM
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OTTO ROSENAU & ASSOCIATES, INC. <br /> Geotechnical Engineering, Construction Inspection& Materials Testing <br /> PROPRIETARY ANCHOR ADHESIVE INSPECTION FIELD REPORT <br /> Job Number: Report Number: 468347 Permit Number: Remodel spaces 4& <br /> 24-0053 5 for gym, ada ramp <br /> &office, minor demo <br /> Project: Waterline Gym Client: <br /> Address: 2900 Grand Avenue, Units 4, 5 Address: <br /> Inspector: John Fraser SI#02055 Date: 5/8/2024 <br /> Description/Location: West Mezzanine: SOMD tie-in dowels <br /> "RFI#004 from Matt Wion-QCE 518124 specified use of grade 40 reinforcing steel <br /> Intended Use: Secure dowels to existing wall Building Code&Year: IBC 2021 <br /> Reinforcing Steel All Thread <br /> Bar/Dowel Size& #4(23) Anchor Size& <br /> Quantity: Quantity: <br /> Rebar Manufacturer: Nucor Type of Steel(ASTM): A36 ❑ F-1554 ❑ A304/316❑ <br /> Grade: NA Other <br /> Rebar Grade: ® 40 60 El Other: 36 ❑ 50 ❑ 75❑ Other: <br /> Type of Bar: ® A-615 ❑A-706 ❑ Other: Does Contractor Need to Schedule Torque Verification? ® Yes ❑ No <br /> Special Ductile Quality(SDQ): ❑Yes N No Reason (if`No): <br /> Anchor Length: 8" Hole 6„ Required 41/2" <br /> Depth: Embedment: <br /> Hole Diameter: 9/16" Concrete 12„+ ConcreteExisting <br /> Thickness: Strength: <br /> Hole Orientation: ❑ Vertical Up ❑ Vertical Down ® Horizontal <br /> Base Material: ® Normal weight concrete ❑ Light Weight Concrete ❑ CMU ❑ Brick ❑ Composite Deck <br /> Hole Cleaning: ❑ Compressed Air ❑ Hand Pump Other: Vacuum Compressed Air PSI: NA <br /> Brushed: ® Yes ❑ No Hole Condition: ® Dry ❑ Damp ❑ Water Saturated ❑ Submerged <br /> Drill Bit(ANSI ® Yes ❑ No Approved Diamond Cored ❑ Yes ® No <br /> B212.15): Hole: <br /> Adhesive Simpson Set 3G Expiration Date: 10/2024 ICC ESR#: 4057 <br /> Manufacturer/Type: <br /> Weather: Indoors Ambient Temp: 640 Substrate Temp: 65° <br /> Inspected by: l_— Reviewed by: <br /> This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates, Inc. Reproduction of this report, <br /> except in full,without written permission from our firm is strictly prohibited. <br /> Page 1 of 2 <br /> 6747 M.L. King Way S.,Seattle,Washington 98118-Phone(206)725-4600 or 1-888-OTTO-4-US-Fax(206)723-2221 <br /> Form No.:INSP-86-02 LT(Rev 05113) <br />
The URL can be used to link to this page
Your browser does not support the video tag.