My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE WATERLINE GYM 2025-01-10
>
Address Records
>
GRAND AVE
>
2900
>
WATERLINE GYM
>
2900 GRAND AVE WATERLINE GYM 2025-01-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2025 11:18:32 AM
Creation date
1/10/2025 10:33:41 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
WATERLINE GYM
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OTTO ROSENAU & ASSOCIATES, INC. <br /> Geotechnical Engineering, Construction Inspection & Materials Testing <br /> PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT <br /> Report Number: PAA466411 Job No.: 24-0053 <br /> Project Name: Waterline Gym Permit: B2306-070 <br /> Project Address: 2900 Grand Avenue, Units 4, 5, Everett <br /> Inspector: Ernest Leimkuhler (WABO#: SI 01954) <br /> Client Name: CH Grand LLC Insp. Date:04/17/2024 <br /> Description / Location / Intended Use J <br /> Epoxy Anchor bolts for structural steel deck ledgers to Concrete walls <br /> Per: 9/S3.0, At: A.0/7.0-8.0, Mezzanine level <br /> Building Code&Year: 2018 IBC <br /> ❑ Reinforcing Steel All Thread <br /> Bar/Dowel Size &Quantity: Anchor Size&Quantity: 3/4" (19) <br /> Rebar Manufacturer: Type of Steel (ASTM): ❑d A-36 ❑ F-1554 ❑ A-307 <br /> Rebar Grade❑40 ❑60 [-]Other: Grade: W 36 ❑ 50 ❑ 75 ❑ Other: <br /> Type of Bar ❑A-615 ❑A-706 ❑Other: Does Contractor Need to Schedule Torque Verification? ❑d Yes ❑ No <br /> Special Ductile Quality(SDQ) Steel: Reason (If No): <br /> Anchor Length: 8" Hole Depth: 5.5" Required Embedment: 5" <br /> Hole Diameter: 7/8" Concrete Thickness: Concrete Strength: <br /> Hole Orientation: ❑Vertical Down ❑ Upwardly Inclined W Horizontal <br /> Base Material: W Normal Weight Concrete ❑ Lightweight Concrete ❑ CMU ❑ Brick ❑ Composite Deck <br /> Hole Cleaning: W Compressed Air ❑ Hand Pump ❑ Vacuum Drill Bit ❑ Other <br /> Compressed Air PSI: 150 Drill Bit(ANSI B212.15): Yes <br /> Brushed: Yes Hole Condition: W Dry ❑ Damp ❑ Water Saturated ❑ Submerged <br /> Adhesive Manufacturer/Type: Simpson Set 3G7777Expiration Date: 10/2025 ICC ESR#: 4057 <br /> Certified Installers: <br /> Weather: Indoors/dry Ambient Temperature: 55 Substrate Temperature: 56 <br /> Reference Standard(s) Used: 2018 IBC Conforms? ❑ Yes ❑ No <br /> Comments: <br /> Date: 2024.04.23 <br /> Copies to: 08:11 :25 -07'00' <br /> Client 0 Engineer ❑ Others Technical Responsibility: <br /> ❑ Owner [41 Contractor <br /> v]Architect W Building Dept Isaac Ruoff, Project Manager <br /> This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates, Inc. Reproduction of this <br /> report except in full,without written permission from our firm is strictly prohibited. <br /> 6747 M.L.King Way S.,Seattle,Washington 98118-Phone(206)725-4600--Fax(206)723-2221 <br /> Form No.:ADMIN-86-04(Rev 01124) Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.